{"id":3851,"date":"2026-08-20T16:34:54","date_gmt":"2026-08-20T16:34:54","guid":{"rendered":"https:\/\/huyuglobal.com\/?p=3851"},"modified":"2026-08-20T16:34:56","modified_gmt":"2026-08-20T16:34:56","slug":"type-w-meaning","status":"publish","type":"post","link":"https:\/\/huyuglobal.com\/id\/blog\/type-w-meaning\/","title":{"rendered":"Arti Tipe W"},"content":{"rendered":"<p>If you&#8217;ve found yourself specifying cable for a construction site, a generator, a mining operation or a portable power distribution system, you have probably come across the term &#8220;Type W&#8221; and faced the confusion it brings. &#8220;W\u201d for what? Water? Weather? Wire? And what&#8217;s its difference from SOOW, which has &#8220;W&#8221; in it as well? Here\u2019s the information you need to know: Type W refers to a UL designation of heavy-duty portable power cable with a voltage rating of up to 2000 volts, made with thick EPDM insulation and a hard CPE jacket suitable for the most extreme industrial conditions. The article discusses what Type W actually means, its applications, how to distinguish it from SOOW and other portable cables and how to choose the right one.<\/p>\n<blockquote><p>Brief note: Type W relates to the UL classification of a portable power cable suitable for the high voltage of up to 2000V (since single conductors also simultaneously receive RHH\/RHW rating for 600V). Type W features thermoset EPDM rubber insulation and jacket made of either CPE or CSPE materials, and the operation temperature ranges from -40\u00b0C to +90\u00b0C, while the construction is perfect for using in harsh environments such as mining, construction sites, rig drilling, or in pumps. The letter \u201dW\u201d indicates that this is a specific type of this type of cable which cannot be confused with the meaning of \u201dW\u201d in SOOW, because here it means that the cord is weatherproof. Type W has huge advantages over SOOW as it provides higher voltage rating, better insulation, and more durability.<\/p><\/blockquote>\n<h2>What Does &#8220;Type W&#8221; Mean?<\/h2>\n<p>Established by Underwriters Laboratory, the Type W designation classifies a type of cable that\u2019s durable enough to stand up to harsher applications. It\u2019s also known as a portable power cable, and it is one of the major types of cable that\u2019s used for power delivery in commercial settings.<\/p>\n<p>Defining properties of Type W cable:<\/p>\n<ul>\n<li>Voltage ratings: Type W is rated for a high voltage of up to 2000 volts AC or DC (when several conductors are used) which is significantly more than what standard low voltage cords are rated for. Individual conductors also meet the dual RHH\/RHW rating at a voltage of 600 volts.<\/li>\n<li>Insulation: thermosetting EPDM (ethylene propylene diene monomer) rubber provides resilient and high-temperature resistant insulation material.<\/li>\n<li>Jacket: CPE (chlorinated polyethylene) or CSPE jacket provides reliable protection against corrosive materials and moisture.<\/li>\n<li>Temperature range: -40\u00b0\u0421 to +90\u00b0\u0421.<\/li>\n<li>Conductors: 1 to 5 conductors (black, white, red, green, orange) suitable for high flexibility; AWG ranging from 8 AWG to 500 MCM when used as single conductors and from 8<\/li>\n<li>AWG to 4\/0 AWG when used as multi-conductor wires.<\/li>\n<\/ul>\n<p>To sum it up, Type W cables are the ones that are used when the standard extension cable or even SOOW cable cannot withstand the required current and voltage applications on a job site, mine, etc.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3852\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/08\/Type-W-vs-the-W-in-SOOW.webp\" alt=\"Type W vs the W in SOOW\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2 id=\"confusion\">The &#8220;W&#8221; Confusion: Type W vs the W in SOOW<\/h2>\n<p>The letter \u201cW\u201d comes in two different types of cable designations and they refer to two completely different meanings, making it the biggest area of confusion.<\/p>\n<table>\n<thead>\n<tr>\n<th>Designation<\/th>\n<th>What the &#8220;W&#8221; Means<\/th>\n<th>Full Meaning<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Type W<\/strong> (portable power cable)<\/td>\n<td>&#8220;W&#8221; is simply the <strong>type name<\/strong> for this heavy-duty portable power cable family<\/td>\n<td>UL Type W \u2014 2,000V portable power cable<\/td>\n<\/tr>\n<tr>\n<td><strong>SOOW<\/strong> (service cord)<\/td>\n<td>&#8220;W&#8221; stands for <strong>Water- and weather-resistant<\/strong><\/td>\n<td>S = Severe service, OO = oil-resistant insulation + jacket, W = weather\/water resistant<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Thus, although both \u201cType W\u201d and \u201cSOOW\u201d have a \u201cW\u201d in their names, in the former \u201cW\u201d is an element in the cable\u2019s name, just as there are types like \u201cType G\u201d and \u201cType SC.\u201d Conversely, in \u201cSOOW,\u201d \u201cW\u201d serves as an adjective indicating that the cable is water-resistant. Thus, anyone searching for \u201ctype w meaning\u201d in relation to cables will be almost always be searching for the UL Type W portable power cable instead of the water resistance.<\/p>\n<h2 id=\"specs\">Type W Cable Specifications<\/h2>\n<p>Here&#8217;s the complete picture of a typical Type W cable:<\/p>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Model<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Cable type<\/td>\n<td>UL Type W (portable power cable)<\/td>\n<\/tr>\n<tr>\n<td>Peringkat tegangan<\/td>\n<td>2,000V AC\/DC (multi-conductor); single conductor dual-rated RHH\/RHW 600V<\/td>\n<\/tr>\n<tr>\n<td>Insulation<\/td>\n<td>Thermoset EPDM rubber<\/td>\n<\/tr>\n<tr>\n<td>Jacket<\/td>\n<td>CPE or CSPE<\/td>\n<\/tr>\n<tr>\n<td>Temperature range<\/td>\n<td>-40\u00b0C to +90\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Conductor count<\/td>\n<td>1-5 (black, white, red, green, orange)<\/td>\n<\/tr>\n<tr>\n<td>Stranding<\/td>\n<td>Rope-lay stranded copper (flexible)<\/td>\n<\/tr>\n<tr>\n<td>Single conductor sizes<\/td>\n<td>8 AWG to 500 MCM<\/td>\n<\/tr>\n<tr>\n<td>Multi-conductor sizes<\/td>\n<td>8 AWG to 4\/0 AWG<\/td>\n<\/tr>\n<tr>\n<td>Resistansi<\/td>\n<td>Excellent abrasion, impact, oil, chemical, and weather resistance<\/td>\n<\/tr>\n<tr>\n<td>Approvals<\/td>\n<td>UL 1650, MSHA flame test, UL flame test, ICEA S-75-381 \/ NEMA WC-58, CSA, RoHS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The notable features here are the 2,000V rating (approximately 3.3 times that of the 600V SOOW), along with a thick and sturdy jacket that has no trouble with rocks, vehicles or bad weather.<\/p>\n<h2>What Is Type W Cable Used For?<\/h2>\n<p>Type W is preferred everywhere portable machinery needs high voltage, high current, and strong construction:<\/p>\n<ul>\n<li>Mining \u2014 energizing drills, conveyors, pumps, and transport equipment (MSHA-approved for mining).<\/li>\n<li>Construction \u2014 temporary electrical supply from generators to panels, welders, and heavy machines.<\/li>\n<li>Rental of generators \u2014 connecting generators to distributing boxes and transferring equipment.<\/li>\n<li>Oil, gas, and drilling rigs \u2014 energizing mud pumps, winches, and devices on the drilling sites.<\/li>\n<li>Marine transportation \u2014 providing shore power and heavy marine operations.<\/li>\n<li>Entertainment \u2014 ensuring high-power distribution from production trucks.<\/li>\n<li>Industry\u2014 temporary electrical supply for maintenance, downtime, and transport machinery.<\/li>\n<li>Pumps and cranes \u2014 motors that use a lot of current over a long distance.<\/li>\n<\/ul>\n<p>Being rated as RHH\/RHW, Type W can act as versatile connection wire in conduits.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3853\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/08\/Type-W-vs-SOOW.webp\" alt=\"Type W vs SOOW\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>Type W vs SOOW: The Key Differences<\/h2>\n<div>Type W and SOOW are the two most common industrial portable cables, and buyers constantly compare them:<\/div>\n<div><\/div>\n<table>\n<thead>\n<tr>\n<th>Fitur<\/th>\n<th>Type W<\/th>\n<th>SOOW<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Category<\/td>\n<td>Portable power cable<\/td>\n<td>Service cord<\/td>\n<\/tr>\n<tr>\n<td>Peringkat tegangan<\/td>\n<td><strong>2,000V<\/strong><\/td>\n<td>600V<\/td>\n<\/tr>\n<tr>\n<td>Insulation<\/td>\n<td>Thicker EPDM<\/td>\n<td>EPDM (thinner)<\/td>\n<\/tr>\n<tr>\n<td>Jacket<\/td>\n<td>Heavy CPE\/CSPE \u2014 maximum abrasion\/impact<\/td>\n<td>CPE \u2014 tough but more flexible<\/td>\n<\/tr>\n<tr>\n<td>Flexibility<\/td>\n<td>Stiffer, heavier<\/td>\n<td>More flexible, easier to coil and route<\/td>\n<\/tr>\n<tr>\n<td>Durability<\/td>\n<td>Superior \u2014 survives vehicles, rocks, crushing<\/td>\n<td>Good \u2014 suited to most job sites<\/td>\n<\/tr>\n<tr>\n<td>Typical sizes<\/td>\n<td>8 AWG to 4\/0 (multi-conductor); up to 500 MCM single<\/td>\n<td>18 to 6 AWG typical<\/td>\n<\/tr>\n<tr>\n<td>Key approvals<\/td>\n<td>UL 1650, MSHA, CSA<\/td>\n<td>UL\/CSA, NEC Article 400<\/td>\n<\/tr>\n<tr>\n<td>Biaya<\/td>\n<td>Higher per foot (more copper + insulation)<\/td>\n<td>Lebih rendah<\/td>\n<\/tr>\n<tr>\n<td>Terbaik untuk<\/td>\n<td>High voltage, mining, heavy machinery, generator distribution<\/td>\n<td>Tools, motors, portable equipment under 600V<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>In a nutshell: be below 600V and need flexibility? Choose SOOW; need 600V-2,000V, can afford having its mining suitability certified or functions at its maximum tensile strength? Choose Type W.<\/p>\n<h2>Type W vs Other Portable Cables (SJOOW, SEOOW, STOW, Type G)<\/h2>\n<p>The portable-cable family has many members; here&#8217;s how Type W stacks up:<\/p>\n<table>\n<thead>\n<tr>\n<th>Cable Type<\/th>\n<th>Tegangan<\/th>\n<th>Key Feature<\/th>\n<th>Penggunaan Terbaik<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>SJOOW<\/strong><\/td>\n<td>300V<\/td>\n<td>&#8220;Junior&#8221; service cord \u2014 thin, flexible<\/td>\n<td>Light tools, small appliances<\/td>\n<\/tr>\n<tr>\n<td><strong>SOOW<\/strong><\/td>\n<td>600V<\/td>\n<td>Severe-service cord, oil + water resistant<\/td>\n<td>General industrial tools and equipment<\/td>\n<\/tr>\n<tr>\n<td><strong>SEOOW<\/strong><\/td>\n<td>600V<\/td>\n<td>Thermoplastic elastomer jacket<\/td>\n<td>Freezing environments, extreme cold<\/td>\n<\/tr>\n<tr>\n<td><strong>STOW<\/strong><\/td>\n<td>600V<\/td>\n<td>Thermoplastic (PVC) jacket<\/td>\n<td>Consumer-grade extension cords<\/td>\n<\/tr>\n<tr>\n<td><strong>Type W<\/strong><\/td>\n<td>2,000V<\/td>\n<td>Heavy portable power cable, MSHA<\/td>\n<td>Mining, high-voltage distribution, heavy equipment<\/td>\n<\/tr>\n<tr>\n<td><strong>Type G<\/strong><\/td>\n<td>2,000V<\/td>\n<td>Very similar to Type W; ground conductors included in the assembly<\/td>\n<td>Portable power distribution with integrated ground<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Type W and Type G can almost be regarded as siblings as both of them are portable power cables rated at 2,000V, which means they can withstand and endure a lot of wear and tear. What separates Type W from Type G however is that Type G constructions typically come with grounding conductors as part of the package while Type W depends on the conductor arrangement that has been specified to achieve grounding. In most instances high voltage portable work can be achieved through the usage of either dressing; it is just important to check which dressing is most appropriate for the job at hand.<\/p>\n<h2>Approvals &amp; Standards<\/h2>\n<p>Type W cable possesses numerous certifications that guarantee its success in many applications:<\/p>\n<ul>\n<li>UL 1650 \u2014 This is the portable power cable standard.<\/li>\n<li>UL Type W listing \u2014 Rated for 2,000V in any configuration.<\/li>\n<li>UL dual rated RHH\/RHW \u2014 indicates that the single conductors are rated for 600V as general building wire.<\/li>\n<li>MSHA flame test \u2014 Approved for mining use (needed for underground applications).<\/li>\n<li>ICEA S-75-381 \/ NEMA WC-58 \u2014 They are recognized portable cables standards.<\/li>\n<li>CSA approval \u2014 The Canadian qualification.<\/li>\n<li>RoHS \u2014 This means that the restricted hazardous substances are not present.<\/li>\n<\/ul>\n<p>If your project is connected to MSHA, you will need Type W cable \u2014 SOOW won\u2019t make it through the inspection.<\/p>\n<h2 id=\"choose\">How to Choose: Type W or SOOW?<\/h2>\n<p>Proceed to ask the following questions in order:<\/p>\n<ul>\n<li>What is the required voltage for the equipment? For any voltage greater than 600V, Type W is the choice. For voltages equal to or below 600V, both options would suffice.<\/li>\n<li>How severe is the working environment? If mining is involved (severe pressure from rocks, equipment being dragged over cables, heavy crushing etc.), it is advisable to go with Type W since its jacket is thicker.<\/li>\n<li>Do you need permission from MSHA? If the application is taking place underground, choose Type W.<\/li>\n<li>How flexible should your cable be? If flexing around tight corners, twisting and turning is required, it is preferable to go for SOOW.<\/li>\n<li>Working under how much money? Type W has a higher price than SOOW, if less than 600V is needed, choose SOOW.<\/li>\n<\/ul>\n<h2>Safety &amp; Usage Rules<\/h2>\n<ul>\n<li>Examine before every use \u2014 look for any damage such as cuts, scrapes, compression areas, or exposed wires; Type W is durable, but it is not indestructible.<\/li>\n<li>Do not use as a permanent building wire within walls \u2014 it is a portable wire; for permanent electrical work, the wiring used is THHN\/THWN with conduit.<\/li>\n<li>Do not direct bury unless the construction is designed to be buried \u2014 check the jacket markings and local requirements.<\/li>\n<li>Choose the correct ampacity according to the load \u2014 Type W wire can take 2,000V but this refers to the voltage capacity and not the ampacity.<\/li>\n<li>Prevent damage \u2014 use ramps or elevated ways where trucks and cars travel on the cable; avoid putting the cable in standing and stagnant water.<\/li>\n<li>Scrape off the oil and other chemicals immediately after the cable is overexposed to them \u2014 the coat of the cable can be oil-resistant, but it will hold longer without these chemicals.<\/li>\n<\/ul>\n<h2>Prices &amp; Where to Buy<\/h2>\n<p>The reason behind the higher price of Type W in comparison to SOOW is that Type W uses more copper and heavier insulation material. Typical pricing estimates per foot for 2025-2026 (for multi-conductor copper wire) is as follows:<\/p>\n<table>\n<thead>\n<tr>\n<th>Conductor Size<\/th>\n<th>Typical Price per Foot<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>8 AWG (3-4 conductors)<\/td>\n<td>$4-$8<\/td>\n<\/tr>\n<tr>\n<td>6 AWG<\/td>\n<td>$6-$12<\/td>\n<\/tr>\n<tr>\n<td>4 AWG<\/td>\n<td>$8-$16<\/td>\n<\/tr>\n<tr>\n<td>2 AWG<\/td>\n<td>$12-$24<\/td>\n<\/tr>\n<tr>\n<td>1 AWG<\/td>\n<td>$15-$30<\/td>\n<\/tr>\n<tr>\n<td>1\/0 AWG<\/td>\n<td>$18-$38<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Different pricing applies depending on the wiring installation, based on the conductor number, insulation material, and supplier; however, the cost is lowered greatly when purchased in bulk from the wire distributor.For buyers building distribution systems around portable power \u2014 generators, transfer switches, and the protection gear behind them \u2014 pairing the right cable with the right <a href=\"https:\/\/huyuglobal.com\/id\/blog\/what-is-mccb-and-mcb\/\" rel=\"nofollow\">MCB\/MCCB protection<\/a> and a certified <a href=\"https:\/\/huyuglobal.com\/id\/blog\/what-is-ul-489-breakers\/\" rel=\"nofollow\">UL 489 breaker<\/a> keeps the whole power chain safe and code-compliant \u2014 and when a breaker eventually needs replacing, the costs in <a href=\"https:\/\/huyuglobal.com\/id\/blog\/how-much-to-replace-a-circuit-breaker\/\" rel=\"nofollow\">our breaker replacement guide<\/a> help you budget the job.<\/p>\n<h2 id=\"faq\">Pertanyaan yang Sering Diajukan<\/h2>\n<h3>What is the main difference between Type W and SOOW cables?<\/h3>\n<p>The differences between them consist of their ratings and durability: Type W has a tough portable power cable rated for extreme use with voltages of up to 2,000V thanks to its thick layers of EPDM insulation and CPE jacket while SOOW is a more flexible and less costly cable rated for 600V use. Type W is also MSHA-approved for use in mines. Use SOOW at less than 600V if flexibility is required; choose Type W for any higher voltage or maximum durability.<\/p>\n<h3>Does SOOW cable need to be in conduit?<\/h3>\n<p>NO \u2013 SOOW is a service cord that makes it possible to operate without conduit&#8217;s help in a flexible application (NEC Article 400). Its use for permanent installation is not permitted, and it is not approved for underground installation. Permanent installation requires the use of building wires (THHN\/THWN) and conduit, while SOOW can be employed for portable power supply tasks.<\/p>\n<h3>What voltage is SOOW rated for?<\/h3>\n<p>SOOW has a voltage rating of 600 volts (plus 300V versions referred as junior SJOOW). SOOW cable can be used for applications involving most power tools, motors as well as machinery. However, Type W cable is required for higher voltage systems as well as for mining operations requiring MSHA approval.<\/p>\n<h3>Can Type W cable be used as building wire?<\/h3>\n<p>Single conductor Type W is a dual rated cable with both RHH and RHW ratings up to 600 volts. For this reason, single conductor Type W can be used as industrial hook-up wire in conduit up to 600 volts. However, while multi-conductor Type W is meant to be used for temporary power, using this type for permanent installation is not recommended. Always check local codes in accordance to the specific use of the cable.<\/p>\n<h2>Referensi<\/h2>\n<ol>\n<li><a href=\"https:\/\/www.awcwire.com\/power-cable-and-portable-cord\/type-w\" rel=\"nofollow noopener\" target=\"_blank\">Allied Wire &amp; Cable \u2014 Type W Cable Specifications and Applications<\/a><\/li>\n<li><a href=\"https:\/\/www.ul.com\/\" rel=\"nofollow noopener\" target=\"_blank\">UL \u2014 UL 1650 Portable Power Cable Standard &amp; Type W Listing<\/a><\/li>\n<li><a href=\"https:\/\/www.msha.gov\/\" rel=\"nofollow noopener\" target=\"_blank\">MSHA \u2014 Mine Safety and Health Administration Cable Requirements<\/a><\/li>\n<li><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\" rel=\"nofollow noopener\" target=\"_blank\">NFPA 70 (NEC) \u2014 Article 400 Flexible Cords and Cables<\/a><\/li>\n<li><a href=\"https:\/\/www.nema.org\/\" rel=\"nofollow noopener\" target=\"_blank\">NEMA \u2014 NEMA WC-58 Portable and Power Feeder Cables<\/a><\/li>\n<li><a href=\"https:\/\/www.automationdirect.com\/flexible-portable-cord\" rel=\"nofollow noopener\" target=\"_blank\">AutomationDirect \u2014 Portable Cord and Type W Selection Guide<\/a><\/li>\n<\/ol>\n<h2>Kesimpulan<\/h2>\n<p>Type W is the UL designation used for the heavy-duty flexible power cable that is sought after in industrial environments when the task is major and the surroundings difficult: rated for 2000 volts, made of the EPDM rubber material and CPE plastic, able to work in the temperature range from -40 to +90 degrees Celsius, MSHA compliant for mining applications. The \u201cW\u201d refers to the type of the cable and not to the \u201cwater resistant\u201d W in SOOW, which is a different cable type working on 600 volts with higher flexibility and lower cost. Use SOOW cable for general-purpose portable tools, and Type W for high voltage power distribution, mining, generators, and heavy machinery \u2014 and always combine this cable with approved safety equipment.<\/p>","protected":false},"excerpt":{"rendered":"<p>If you&#8217;ve found yourself specifying cable for a construction site, a generator, a mining operation or a portable power distribution system, you have probably come across the term &#8220;Type W&#8221; and faced the confusion it brings. &#8220;W\u201d for what? Water? Weather? Wire? And what&#8217;s its difference from SOOW, which has &#8220;W&#8221; in it as well? [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3854,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-3851","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/posts\/3851","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/comments?post=3851"}],"version-history":[{"count":2,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/posts\/3851\/revisions"}],"predecessor-version":[{"id":3861,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/posts\/3851\/revisions\/3861"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/media\/3854"}],"wp:attachment":[{"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/media?parent=3851"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/categories?post=3851"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/tags?post=3851"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}