{"id":4037,"date":"2026-08-28T09:30:19","date_gmt":"2026-08-28T09:30:19","guid":{"rendered":"https:\/\/huyuglobal.com\/?p=4037"},"modified":"2026-08-28T09:30:21","modified_gmt":"2026-08-28T09:30:21","slug":"12-gauge-wire","status":"publish","type":"post","link":"https:\/\/huyuglobal.com\/id\/blog\/12-gauge-wire\/","title":{"rendered":"Kabel 12 Gauge: Panduan Lengkap untuk Spesifikasi, Ampacity, Penggunaan, dan Biaya"},"content":{"rendered":"<p>Jika Anda bertanya kepada tukang listrik mana kawat yang paling serbaguna dalam instalasi residensial atau komersial ringan, jawabannya hampir selalu sama: 12 AWG (12 gauge). Memang, ini adalah kabel terkecil yang diizinkan oleh National Electric Code untuk sirkuit cabang 20 amp; yaitu, sirkuit cabang yang memasok sebagian besar dapur, kamar mandi, garasi, dan peralatan listrik. Namun, pertanyaan tentang subjek ini tidak pernah berhenti muncul: berapa ampere yang dimiliki kawat #12? Apakah setara dengan kawat 12 AWG? Bisakah saya mengalirkan 25 ampere melalui kawat ini untuk beberapa waktu? Dan juga mengapa kawat di toko harganya jauh lebih mahal daripada THHN di gudang?<\/p>\n<p>Manual ini memberikan jawaban untuk setiap pertanyaan ini: berapa dimensi fisik 12 AWG, apa aturan ampacity menurut persyaratan Kode, di mana kabel ini harus dan tidak boleh digunakan, berapa harga per kaki untuk semua jenis isolasi umum, bagaimana kawat ini dibandingkan dengan kawat gauge 14, 10, dan 8 serta di mana membelinya.<\/p>\n<blockquote><p>Diameter konduktor kawat tembaga 12 AWG adalah 0,0808 inci (2,05 mm), menjadikannya minimum yang diwajibkan NEC untuk sirkuit 20 amp (NEC 240.4 (D)). Tingkat ampacity maksimum untuk jenis konduktor ini adalah 20 amp pada 60\u00b0C (kabel NM-B) dan 25 amp pada 75\u00b0C (THHN\/THWN dalam pipa) sesuai dengan NEC Tabel 310.15 (B) (16). Ini berarti meskipun kawat memiliki kapasitas maksimum 25 amp, batas 20 amp harus dihormati karena pemutus sirkuit harus melindungi kawat. Tidak disarankan menggunakan 25 amp pada kawat 12 AWG untuk sirkuit aplikasi umum.<\/p><\/blockquote>\n<h2>Apa Itu Kawat Gauge 12? Ukuran dan Dimensi<\/h2>\n<p>\u201cGauge\u201d adalah tentang sistem pengkabelan yang disebut sistem American Wire Gauge (AWG); pada AWG, angka yang lebih rendah menunjukkan kawat yang lebih tebal. Gauge 12 tembaga padat memiliki diameter 0,0808 inci (sekitar 2,05 mm) dengan penampang sekitar 3,31 mm\u00b2 (6530 mil lingkaran). Isolasi meningkatkan diameter keseluruhan kawat menjadi sekitar 0,119-0,128 inci, tergantung pada jenis isolasi yang digunakan dan apakah kawat memiliki konduktor stranded atau padat.<\/p>\n<p>Ada dua bentuk kawat; konduktor padat, yaitu satu kawat kaku yang digunakan dalam kabel NM-B (Romex), dan kawat stranded, yang terbuat dari 19 helai yang dipilin bersama dan digunakan dalam kawat THHN, serta dalam aplikasi fleksibel. Yang terakhir lebih fleksibel dan memiliki toleransi lebih tinggi terhadap pembengkokan, yang membuat kawat stranded lebih cocok untuk berbagai sistem listrik.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4039\" style=\"text-align: center;\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/08\/How-Many-Amps-Can-12-AWG-Carry.webp\" alt=\"Berapa Ampere yang Bisa Dibawa 12 AWG? Aturan Kode\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>Berapa Ampere yang Bisa Dibawa 12 AWG? Aturan Kode<\/h2>\n<p>Kapasitas kabel kawat tembaga 12 AWG ditentukan oleh rating suhu isolasi, sementara spesifikasi sirkuit ditentukan oleh mekanisme proteksi pemutus sirkuit. Ada dua jenis nilai:<\/p>\n<ul>\n<li>Kapasitas konduktor (kapasitas fisik kawat), seperti yang ditunjukkan dalam NEC Tabel 310.15(B)(16), di mana kawat memiliki kapasitas 25 ampere pada 75\u00b0C (kabel THHN\/THWN dalam pipa) dan 30 ampere pada 90\u00b0C (pengkabelan THHN dengan terminal yang dapat bekerja pada 90\u00b0C).<\/li>\n<li>Kapasitas sirkuit (kapasitas mekanisme protektif), sebagaimana ditetapkan dalam NEC 240.4(D), di mana pemutus sirkuit harus memberikan perlindungan untuk kawat tembaga 12 AWG dengan rating tidak melebihi 20 ampere.<\/li>\n<\/ul>\n<p>Penggunaan berarti bahwa sirkuit 12 AWG memiliki pemutus sirkuit berperingkat 20 Ampere, sementara kawat dapat beroperasi di bawah beban kontinu sebesar 16 Ampere (aturan 80%). Rating 25 Ampere pada 75\u00b0C ada untuk margin keamanan dan untuk beberapa pengecualian dalam kode, bukan untuk menghubungkan pemutus sirkuit 25A ke kawat 12 AWG. Jika ada keraguan tentang kawat yang akan digunakan, disarankan mengikuti sirkuit dengan rating lebih rendah yang akan memastikan keamanan kawat.<\/p>\n<h2>Jenis 12 AWG: THHN, NM-B, UF-B, MC \u2014 Apa Perbedaannya<\/h2>\n<p>Berbagai gaya isolasi\/konstruksi ada untuk 12 AWG, masing-masing memiliki kode instalasi sendiri.<\/p>\n<table>\n<thead>\n<tr>\n<th>Tipe<\/th>\n<th>Konstruksi<\/th>\n<th>Ampacity (12 AWG Cu)<\/th>\n<th>Di Mana Ini Digunakan<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>THHN\/THWN-2<\/td>\n<td>Konduktor tunggal, isolasi PVC + jaket nilon<\/td>\n<td>25A (75\u00b0C); 30A (90\u00b0C)<\/td>\n<td>Saluran dan baki kabel di komersial\/industri; 600V; lokasi basah atau kering<\/td>\n<\/tr>\n<tr>\n<td>NM-B (Romex)<\/td>\n<td>2-4 konduktor dalam selubung PVC, padat atau stranded<\/td>\n<td>20A (60\u00b0C)<\/td>\n<td>Residensial dan komersial ringan, tersembunyi di dinding\/plafon<\/td>\n<\/tr>\n<tr>\n<td>UF-B<\/td>\n<td>Gaya NM dengan jaket tahan kelembaban<\/td>\n<td>20A (60\u00b0C)<\/td>\n<td>Pengumpan bawah tanah ke gudang\/garasi dan jalur luar ruangan<\/td>\n<\/tr>\n<tr>\n<td>Kabel MC<\/td>\n<td>Konduktor di dalam pelindung logam fleksibel<\/td>\n<td>20A (rating 75\u00b0C tipikal)<\/td>\n<td>Komersial, jalur terbuka, area berperingkat api<\/td>\n<\/tr>\n<tr>\n<td>THW\/THWN tunggal<\/td>\n<td>Mirip dengan keluarga THHN<\/td>\n<td>25A (75\u00b0C)<\/td>\n<td>Lokasi basah, pengumpan industri<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Salah satu pilihan baik untuk jalur saluran adalah THHN\/THWN-2, yang lebih murah per kaki dibandingkan kawat NM-B karena hanya menggunakan satu konduktor dalam kawat ini, sedangkan NM-B (merek Romex milik Southwire) adalah kawat standar yang digunakan dalam instalasi kasar residensial. UF-B digunakan untuk instalasi kawat bawah tanah, dan MC adalah nama kawat berpelindung yang digunakan dalam instalasi komersial.<\/p>\n<h2>Di Mana Gauge 12 Digunakan (dan Di Mana Tidak)<\/h2>\n<p>Menurut Pasal 210 dari kode NEC, sirkuit untuk peralatan kecil di dapur, area makan, dan laundry harus 20 ampere (210.52), dan pada saat yang sama, sirkuit untuk kamar mandi juga harus 20 ampere (210.11(C)(3)). Semua sirkuit ini harus dipasang dengan kawat 12 AWG. Aplikasi standar lainnya:<\/p>\n<ul>\n<li>Stopkontak dapur dan area makan \u2013 sirkuit untuk peralatan kecil 20 ampere diwajibkan oleh kode;<\/li>\n<li>Sirkuit stopkontak kamar mandi \u2013 20 ampere dan dilengkapi dengan GFCI;<\/li>\n<li>Stopkontak garasi dan bengkel \u2013 20 ampere untuk alat termasuk gergaji meja dan pengumpul debu;<\/li>\n<li>Unit pendingin udara jendela \u2013 15 ampere berjalan pada sirkuit 20 ampere dengan kawat 12 AWG;<\/li>\n<li>Outlet tujuan umum dan penerangan di bangunan baru \u2013 banyak teknisi listrik menggunakan kawat 12 AWG di seluruh bangunan dengan atau tanpa pencampuran dengan 14.<\/li>\n<li>Jalur pengumpan ke sub-panel dan struktur \u2013 biasanya, jalur pengumpan pendek dalam ampacity yang diizinkan; jalur pengumpan panjang harus 10 AWG atau lebih tebal.<\/li>\n<\/ul>\n<p>Di mana 12 AWG tidak sesuai: sirkuit pencahayaan 15A dapat bekerja dengan baik pada kabel 14 AWG; peralatan 240V di atas 20A harus dihubungkan menggunakan kabel minimal 10 AWG; jalur feeder panjang harus menggunakan kabel dengan ukuran lebih besar karena penurunan tegangan. Jika Anda sedang memasang kabel subpanel atau peralatan berat, panduan kami tentang <a href=\"https:\/\/huyuglobal.com\/id\/blog\/how-many-watts-on-a-15-amp-circuit\/\">apa yang sebenarnya dapat dibawa oleh sirkuit 15 amp<\/a> dan yang <a href=\"https:\/\/huyuglobal.com\/id\/blog\/what-is-mccb-and-mcb\/\">Perbandingan MCB vs MCCB<\/a> membantu Anda mencocokkan kabel dengan pemutus sirkuit dan beban dengan benar.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4040\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/08\/12-AWG-vs-14-10-and-8-Gauge-How-to-Choose.webp\" alt=\"12 AWG vs 14, 10, dan 8 Gauge: Cara Memilih\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>12 AWG vs 14, 10, dan 8 Gauge: Cara Memilih<\/h2>\n<table>\n<thead>\n<tr>\n<th>AWG (tembaga)<\/th>\n<th>Diameter<\/th>\n<th>Max Circuit (NEC 240.4(D))<\/th>\n<th>Ampacity 75\u00b0C<\/th>\n<th>Penggunaan Umum<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>14 AWG<\/td>\n<td>0.0641&#8243; (1.63 mm)<\/td>\n<td>15A<\/td>\n<td>20A<\/td>\n<td>Lighting, 15A general circuits<\/td>\n<\/tr>\n<tr>\n<td>12 AWG<\/td>\n<td>0.0808&#8243; (2.05 mm)<\/td>\n<td>20A<\/td>\n<td>25A<\/td>\n<td>Kitchen\/bath\/garage receptacles, tools<\/td>\n<\/tr>\n<tr>\n<td>10 AWG<\/td>\n<td>0.1019&#8243; (2.59 mm)<\/td>\n<td>30A<\/td>\n<td>35A<\/td>\n<td>Water heaters, AC units, EV chargers<\/td>\n<\/tr>\n<tr>\n<td>8 AWG<\/td>\n<td>0.1285&#8243; (3.26 mm)<\/td>\n<td>40A<\/td>\n<td>50A<\/td>\n<td>Dryers, subpanel feeders<\/td>\n<\/tr>\n<tr>\n<td>6 AWG<\/td>\n<td>0.162&#8243; (4.11 mm)<\/td>\n<td>55A<\/td>\n<td>65A<\/td>\n<td>Range, heavy feeders<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The basic rule of thumb is that the wires should match the circuit breaker, and the circuit breaker should match the load. Whenever the circuit is designed for a potential load of 20A (for example, in kitchens, bathrooms, garages and workshops) it makes sense to use 12 AWG cable. For circuits that are strictly 15A lighting circuits, using 14 AWG copper cable is advisable because it will save you money as well as being compliant with the local electrical codes. For loads that operate at 240V and demand from 25-30A, it is better to switch to 10 AWG. A lot of electricians make an effort not to switch wire sizes throughout the job and often use 12 AWG wire even when it is not required by the regulations since the additional cost is minimal and there is no need to fear that you will use the wrong wire.<\/p>\n<h2>Voltage Drop and Run Length<\/h2>\n<p>Voltage drop is one of the costs that go unnoticed in long wires. For a circuit carrying 20A for 50 feet, 12 AWG copper wire will show a voltage drop of about 2.8V (2.3%), which is acceptable under the National Electrical Code (NEC) recommendations of 3% for branch circuits. However, 14 AWG copper wire in a similar run will drop 4.5V (3.75%), which is above the limit. Extended wiring lowers the starting torque of motors, dims lights and can cause other problems. In practice, if we need to run 20A for distances longer than 75-100 feet, it is recommended to either switch to 10 AWG wire or use two circuits. If the wire should be longer than 100 feet, the calculation of voltage drop according to NEC Chapter 9, table 8 is necessary.<\/p>\n<h2>Copper vs Aluminum<\/h2>\n<p>Because copper is nearly as good a conductor as the theoretical 100% efficacy (95%), but because of its many advantages, copper is the preferred metal to be used in branch circuits. Although aluminum is almost one-third lighter, the codes specify that aluminum wires must be two gauges larger than copper wires and that special connections must be used with this material. Therefore, 12-gauge wires are never going to be aluminum wires; however, the latter would be used to minimize costs in main service feeder cables.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4041\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/08\/How-Much-Does-12-Gauge-Wire-Cost.webp\" alt=\"How Much Does 12 Gauge Wire Cost\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>How Much Does 12 Gauge Wire Cost?<\/h2>\n<p>Copper market rates vary, but the prices for 12 AWG copper in the USA remain constant.<\/p>\n<table>\n<thead>\n<tr>\n<th>Produk<\/th>\n<th>Harga Tipikal<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>THHN 12 AWG single conductor (loose)<\/td>\n<td>$0.39-0.56 per foot (bulk 1000-ft pricing at the low end)<\/td>\n<\/tr>\n<tr>\n<td>12\/2 NM-B cable (Romex-type, with ground)<\/td>\n<td>$0.50-0.80 per foot<\/td>\n<\/tr>\n<tr>\n<td>12\/3 NM-B cable (for 3-way circuits, with ground)<\/td>\n<td>$0.70-1.10 per foot<\/td>\n<\/tr>\n<tr>\n<td>12 AWG NM-B, 100-foot spool<\/td>\n<td>$20-35<\/td>\n<\/tr>\n<tr>\n<td>12 AWG NM-B, 250-500 ft spool (bulk)<\/td>\n<td>$50-170 depending on brand and copper price<\/td>\n<\/tr>\n<tr>\n<td>10 AWG 12\/2 NM-B equivalent (for comparison)<\/td>\n<td>about $1.20 per foot<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Purchasing in bulk is an excellent way to save money: 500-foot wire spools of 12\/2 NM-B from a wholesaler have prices that are up to 30% lower than those charged for buying bulky 50-foot cuts from a retail outlet. Many online wholesalers (like Wire &amp; Cable Your Way and WesBell) post online wire prices that are much lower than those of conventional large retailers for similar UL-registered wire.<\/p>\n<h2>Recommended Brands and Manufacturers<\/h2>\n<p>UL-listed wire is treated as a product of a commodity nature due to the fact that what matters more is the insulation and copper used for the wire, and all the leading brands offer compliance with UL 83\/1063. But there are some brands which have stood firm in the wire making industry:<\/p>\n<ul>\n<li>Southwire \u2014 the biggest wire company in the USA. Its Romex wire brand has become a standard in NM-B wire. It is sold in all leading chain stores and wire distributors.<\/li>\n<li>Cerro Wire \u2014 a well-known company in the USA. It has the prices which are 10-15% higher than other brands, but it offers high-quality insulation.<\/li>\n<li>Wire &amp; Cable Your Way \u2014 a distributor who sells Southwire wire and many similar wires at low prices.<\/li>\n<li>WesBell Electronics \u2014 the company specializes in direct sales and offers THHN wire at per-foot basis.<\/li>\n<li>General Cable\/Prysmian \u2014 an industrial-grade wire THHN and tray cable make.<\/li>\n<\/ul>\n<p>When purchasing wires be sure to check the UL chairman, and the print on wire (12-2 w\/Grd NM-B 600V), the manufacture date code from NM-B spools, and make sure the wire is correctly marked. The price difference between budget wires and premium ones is just several dollars.For the breaker that protects that wire, pairing it with a certified <a href=\"https:\/\/huyuglobal.com\/id\/blog\/what-is-ul-489-breakers\/\">UL 489 breaker<\/a> and understanding <a href=\"https:\/\/huyuglobal.com\/id\/blog\/how-to-tell-if-a-breaker-is-bad\/\">how to spot a failing breaker<\/a> closes the loop on a safe circuit, and in wet locations the <a href=\"https:\/\/huyuglobal.com\/id\/blog\/gfci-stands-for-ground-fault-circuit-interrupter\/\">Panduan perlindungan GFCI<\/a> explains the additional layer 12 AWG circuits need in kitchens and baths.<\/p>\n<h2>Pertanyaan yang Sering Diajukan<\/h2>\n<h3>How many amps will #12 wire carry?<\/h3>\n<p>According to NEC Table 310.15(B)(16), 12 AWG copper can carry current of 25A at 75 degrees Celsius (THHN\/THWN in conduit) and 30A at 90 degrees Celsius. However, it is stated in NEC 240.4(D) that for most applications it must be secured at not more than 20A because NM-B cables and standard terminations are rated for 60 degrees Celsius. The practical result for circuit design is the following: 12 AWG means 20-amp circuit.<\/p>\n<h3>How thick is 12 gauge electrical wire?<\/h3>\n<p>The diameter of bare copper wire of 12 AWG is .0808 inches (2.05 mm). The diameter of wire with THHN insulation is roughly .128 inches (3.25 mm) and the complete NM-B wire assembly is roughly 0.4 x 0.2 inches. It is clearly thicker than 14 AWG (.0641&#8243;) and noticeably thinner than 10 AWG (.1019&#8243;).<\/p>\n<h3>Is 12 gauge and 12 AWG the same thing?<\/h3>\n<p>Yes, AWG means American Wire Gauge and there is no difference between 12 AWG and 12 gauge. It is a system of wire size identification that is used in North America. Both terms are used to describe copper wire with 0.0808 inches in diameter and a 20A circuit capacity (It should be mentioned that in some countries the cross-sectional area of wire is measured in mm2 \u2013 12 AWG is approximately 3.3-4 mm2.).<\/p>\n<h3>Can you run 25 amps on 12 gauge wire?<\/h3>\n<p>No, it is impossible for normal branch circuits. Although 12 AWG THHN is rated for 25 amps at 75 degrees Celsius, NEC 240.4(D) sets the limit for that wire to 20A for copper wires and 20A for 12 AWG wires with insulation rating of 60 degrees Celsius in most cases.<\/p>\n<h2>Referensi<\/h2>\n<ul>\n<li><a href=\"https:\/\/wesbellwireandcable.com\/products\/electrical-wire\/thhn-wire\/copper-thhn-electrical-wire-12-str\/\" rel=\"nofollow noopener\" target=\"_blank\">WesBell Electronics \u2014 THHN 12 AWG stranded copper: specs and pricing<\/a><\/li>\n<li><a href=\"https:\/\/www.lapptannehill.com\/thhn-building-wire-12-awg-brown-stranded-conductor\" rel=\"nofollow noopener\" target=\"_blank\">Lapp Tannehill \u2014 12 AWG THHN building wire technical data<\/a><\/li>\n<li><a href=\"https:\/\/toolsradar.com\/12-gauge-wire-for-20-amp-can-it-handle-your-woodshops-needs\/\" rel=\"nofollow noopener\" target=\"_blank\">ToolsRadar \u2014 12 gauge wire for 20-amp circuits: ampacity and cost analysis<\/a><\/li>\n<li><a href=\"https:\/\/th.qlcables.com\/message?product_id=1576\" rel=\"nofollow noopener\" target=\"_blank\">QL Cables \u2014 NM-B 14-6 AWG pricing and NEC compliance overview<\/a><\/li>\n<li><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70\" rel=\"nofollow noopener\" target=\"_blank\">NFPA 70 \u2014 National Electrical Code (NEC 240.4, Table 310.15(B)(16), Article 210)<\/a><\/li>\n<\/ul>\n<h2>Kesimpulan<\/h2>\n<p>The 12 AWG wire is well known for being the best performing wire when it comes to electrical conduction, being suitable for assisting various electrical appliances such as tools, cooking devices and much more. Its operation is based on the following principles \u2014 the wire has a maximum capacity of carrying 25 amps at 75 degrees Celsius, but the regular breaker has 20 amps. When it comes to purchasing the wire, certain aspects such as type of insulation (NM-B in the case of residential homes, THHN in case of conduit wiring), length of the wire and its material (copper should be preferred over aluminum) become of paramount significance. Finally, with the price fluctuating somewhere between $0.40 and $0.80 per foot, the use of 12 AWG in one\u2019s project is a trivial task when it comes to budgeting.<\/p>","protected":false},"excerpt":{"rendered":"<p>If you ask any electrician what the most versatile wire is in a residential or light commercial installation, the answer will almost always be the same: 12 AWG (12 gauge). Indeed, it is the smallest cable permitted by the National Electric Code for 20-amp branch circuits; this is, the branch circuits supplying most of the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4042,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-4037","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/posts\/4037","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/comments?post=4037"}],"version-history":[{"count":3,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/posts\/4037\/revisions"}],"predecessor-version":[{"id":4044,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/posts\/4037\/revisions\/4044"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/media\/4042"}],"wp:attachment":[{"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/media?parent=4037"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/categories?post=4037"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/huyuglobal.com\/id\/wp-json\/wp\/v2\/tags?post=4037"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}