{"id":3571,"date":"2026-08-08T15:23:36","date_gmt":"2026-08-08T15:23:36","guid":{"rendered":"https:\/\/huyuglobal.com\/?p=3571"},"modified":"2026-08-08T15:23:38","modified_gmt":"2026-08-08T15:23:38","slug":"which-type-of-circuit-breaker-is-designed-to-be-reconditioned","status":"publish","type":"post","link":"https:\/\/huyuglobal.com\/tr\/blog\/which-type-of-circuit-breaker-is-designed-to-be-reconditioned\/","title":{"rendered":"Yeniden Kondisyonland\u0131r\u0131lmak \u00dczere Tasarlanm\u0131\u015f Devre Kesici T\u00fcr\u00fc Hangisidir?"},"content":{"rendered":"<p>Tesisinizde eski tip \u015falt cihazlar\u0131 kullan\u0131l\u0131yorsa, devre kesicilerinizi yenileyip yenileyemeyece\u011finizi veya tamamen yeni cihazlar alman\u0131z gerekip gerekmedi\u011fini merak edebilirsiniz. Cevap o kadar basit de\u011fildir, \u00e7\u00fcnk\u00fc bu tesisinizdeki devre kesici t\u00fcr\u00fcne ba\u011fl\u0131d\u0131r. 2020 Ulusal Elektrik Kodu (NEC) taraf\u0131ndan belirtildi\u011fi gibi, d\u00fc\u015f\u00fck voltajl\u0131 g\u00fc\u00e7 devre kesicileri, orta voltajl\u0131 devre kesiciler ve y\u00fcksek voltajl\u0131 devre kesicilerin yenilenmesine izin verilirken, kal\u0131pl\u0131 kutu devre kesicileri (MCCB'ler), GFCI devre kesicileri ve AFCI kesiciler NEC Madde 210.15 ve B\u00f6l\u00fcm 240.88'e g\u00f6re yenilenmemelidir. Sonu\u00e7 olarak, bu ayr\u0131m, maliyetleri g\u00fcvenlik ve kod uyumu ile dengelemek zorunda olan tesis y\u00f6neticileri, elektrik m\u00fcteahhitleri ve bak\u0131m m\u00fchendisleri i\u00e7in \u00e7ok \u00f6nemlidir.<\/p>\n<blockquote><p><strong>H\u0131zl\u0131 cevap:<\/strong> Yenilenebilen devre kesiciler aras\u0131nda d\u00fc\u015f\u00fck voltajl\u0131 g\u00fc\u00e7 devre kesicileri, orta voltajl\u0131 g\u00fc\u00e7 devre kesicileri ve y\u00fcksek voltajl\u0131 devre kesiciler bulunur. Kal\u0131pl\u0131 kutu devre kesicileri NEC 240.88(A)(1) maddesine g\u00f6re yenilenemez ve ayr\u0131ca GFCI korumas\u0131, AFCI korumas\u0131 veya GFPE sa\u011flayan herhangi bir devre kesicinin yenilenmesi NEC 210.15 taraf\u0131ndan yasakt\u0131r. Fabrika yenileme hizmeti sunan \u00f6nemli \u00fcreticiler \u015funlard\u0131r: Eaton, ABB ve Schneider Electric \/ Square D. Yenileme s\u00fcreci IEEE C37.59 ve NEMA AB 4 kurallar\u0131na ve y\u00f6netmeliklerine uygundur. Genel olarak, yenileme maliyeti yeni bir devre kesicinin -60'\u0131 kadard\u0131r ve 10-20 y\u0131l ek hizmet \u00f6mr\u00fc sa\u011flar.<\/p><\/blockquote>\n<h2>Yenilenmesine \u0130zin Verilen Devre Kesici T\u00fcrleri<\/h2>\n<p>NEC 2020 B\u00f6l\u00fcm 240.88(A) uyar\u0131nca, a\u015fa\u011f\u0131daki <strong>devre kesici t\u00fcrleri<\/strong> a\u00e7\u0131k\u00e7a yenilenmesine izin verilmi\u015ftir:<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3573\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/08\/Circuit-Breaker-Types-Permitted-for-Reconditioning.webp\" alt=\"Yenilenmesine \u0130zin Verilen Devre Kesici T\u00fcrleri\" width=\"1448\" height=\"1086\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Kesici T\u00fcr\u00fc<\/th>\n<th>NEC Referans\u0131<\/th>\n<th>Tipik Uygulama<\/th>\n<th>Voltaj Aral\u0131\u011f\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>D\u00fc\u015f\u00fck voltajl\u0131 g\u00fc\u00e7 devre kesicileri<\/strong><\/td>\n<td>88(A)(2)<\/td>\n<td>\u015ealt cihazlar\u0131nda \u00e7ekmeli devre kesiciler, ana servis devre kesicileri<\/td>\n<td>000V AC'ye kadar<\/td>\n<\/tr>\n<tr>\n<td><strong>Orta voltajl\u0131 g\u00fc\u00e7 devre kesicileri<\/strong><\/td>\n<td>88(A)(3)<\/td>\n<td>End\u00fcstriyel trafo merkezleri, b\u00fcy\u00fck tesis da\u011f\u0131t\u0131m\u0131<\/td>\n<td>000V \u2013 38kV<\/td>\n<\/tr>\n<tr>\n<td><strong>Y\u00fcksek voltajl\u0131 devre kesiciler<\/strong><\/td>\n<td>88(A)(3)<\/td>\n<td>\u015eebeke \u00f6l\u00e7ekli trafo merkezleri, iletim<\/td>\n<td>38kV \u00fczeri<\/td>\n<\/tr>\n<tr>\n<td><strong>\u015ealt panolar\u0131 ve \u015falt cihaz\u0131 b\u00f6l\u00fcmleri<\/strong><\/td>\n<td>8(B), 490.49<\/td>\n<td>T\u00fcm \u015falt cihaz\u0131 hatt\u0131n\u0131n modernizasyonu<\/td>\n<td>\u00c7e\u015fitli<\/td>\n<\/tr>\n<tr>\n<td><strong>Elektromekanik koruma r\u00f6leleri ve CT'ler<\/strong><\/td>\n<td>88(B)(2)<\/td>\n<td>Trafo merkezlerindeki koruma sistemleri<\/td>\n<td>\u00c7e\u015fitli<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Yenilenebilir t\u00fcm <strong>devre kesicilerin<\/strong> temel \u00f6zelli\u011fi, <strong>\u00e7ekmeli veya \u00e7\u0131kar\u0131labilir tipte olmalar\u0131d\u0131r<\/strong> ve bak\u0131m i\u00e7in tasarlanm\u0131\u015flard\u0131r \u2014 kapal\u0131 \u00fcniteler de\u011fildir. D\u00fc\u015f\u00fck voltajl\u0131 g\u00fc\u00e7 devre kesicileri, \u00f6rne\u011fin <a href=\"https:\/\/huyuglobal.com\/tr\/product\/huw9-690v-6300a-air-circuit-breaker\/\">6300A'ye kadar derecelendirilmi\u015f hava devre kesicileri<\/a>, sahada servis yap\u0131labilir mekanizmalar, de\u011fi\u015ftirilebilir kontaklar ve eri\u015filebilir trip \u00fcniteleri ile \u00f6zel olarak tasarlanm\u0131\u015ft\u0131r. Bu, fabrika taraf\u0131ndan m\u00fch\u00fcrlenmi\u015f kal\u0131pl\u0131 kutu devre kesicilerinden temel olarak farkl\u0131d\u0131r.<\/p>\n<h3>G\u00fc\u00e7 Devre Kesicilerinin Yenilenebilme Nedenleri<\/h3>\n<p>Devre kesiciler bak\u0131m yap\u0131lmas\u0131na olanak verecek \u015fekilde tasarlanm\u0131\u015ft\u0131r. \u00d6zellikleri \u015funlard\u0131r:<\/p>\n<ul>\n<li>De\u011fi\u015ftirilebilir Kontaklar \u2013 ark ve ana kontaklar\u0131n muayenesi ve de\u011fi\u015ftirilmesi yap\u0131labilir<\/li>\n<li>Eri\u015filebilir \u0130\u015fletme Mekanizmalar\u0131 \u2013 yaylar, ba\u011flant\u0131lar ve mandallar \u00fczerinde servis yap\u0131labilir<\/li>\n<li>De\u011fi\u015ftirilebilir Trip \u00dcniteleri \u2013 devre kesicilerin elektronik trip \u00fcnitelerinin y\u00fckseltilmesi m\u00fcmk\u00fcnd\u00fcr<\/li>\n<li>\u00c7ekmeli Tasar\u0131m \u2013 kesici, g\u00fcc\u00fc kapatmadan panelden \u00e7\u0131kar\u0131labilir<\/li>\n<li>Geni\u015f Yal\u0131t\u0131m Sistemleri \u2013 mevcut yal\u0131t\u0131m temizlenebilir, test edilebilir ve rehabilite edilebilir<\/li>\n<\/ul>\n<p>Kesici kategorileri aras\u0131ndaki farklar hakk\u0131nda daha fazla bilgi i\u00e7in, rehberimiz <a href=\"https:\/\/huyuglobal.com\/tr\/blog\/what-is-mccb-and-mcb\/\">MCCB ve MCB'nin ne oldu\u011fu<\/a> servis edilebilirli\u011fi belirleyen yap\u0131sal farklar\u0131 kapsar.<\/p>\n<h2 id=\"prohibited-types\">Yeniden Kondisyonlama Yasaklanan Devre Kesici T\u00fcrleri<\/h2>\n<p>NEC 2020'ye g\u00f6re, yenilenmesi yasaklanan ekipmanlar vard\u0131r. Bu yasaklar, bu ekipman\u0131n g\u00fcvenlik a\u00e7\u0131s\u0131ndan kritik do\u011fas\u0131 nedeniyle, i\u00e7indeki herhangi bir de\u011fi\u015fikli\u011fin g\u00fcvenlik \u00f6zelliklerini etkilemesinin ka\u00e7\u0131n\u0131lmaz olmas\u0131 nedeniyle ortaya \u00e7\u0131kmaktad\u0131r.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3574\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/08\/Circuit-Breaker-Types-Prohibited-from-Reconditioning.webp\" alt=\"Yeniden Kondisyonlama Yasaklanan Devre Kesici T\u00fcrleri\" width=\"1448\" height=\"1086\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Yasaklanan Ekipman<\/th>\n<th>NEC Referans\u0131<\/th>\n<th>Sebep<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Kal\u0131planm\u0131\u015f kutu devre kesiciler (MCCB'ler)<\/strong><\/td>\n<td>88(A)(1)<\/td>\n<td>Fabrika m\u00fch\u00fcrl\u00fc; m\u00fchr\u00fcn k\u0131r\u0131lmas\u0131 UL listesi ve kalibrasyonunu ge\u00e7ersiz k\u0131lar<\/td>\n<\/tr>\n<tr>\n<td><strong>GFCI koruma cihazlar\u0131<\/strong><\/td>\n<td>210.15(1)<\/td>\n<td>G\u00fcvenlik a\u00e7\u0131s\u0131ndan kritik personel korumas\u0131; yeniden ko\u015fulland\u0131rma sonras\u0131 kalibrasyon do\u011frulanamaz<\/td>\n<\/tr>\n<tr>\n<td><strong>AFCI koruma cihazlar\u0131<\/strong><\/td>\n<td>210.15(2)<\/td>\n<td>Karma\u015f\u0131k elektronikler ark imzalar\u0131n\u0131 alg\u0131lar; yeniden ko\u015fulland\u0131rma ince bozulmalar\u0131 ka\u00e7\u0131rabilir<\/td>\n<\/tr>\n<tr>\n<td><strong>Ekipman toprak ar\u0131zas\u0131 korumas\u0131 (GFPE)<\/strong><\/td>\n<td>210.15(3)<\/td>\n<td>Ekipman koruma fonksiyonu fabrika kalibrasyonunda kalmal\u0131d\u0131r<\/td>\n<\/tr>\n<tr>\n<td><strong>LV g\u00fc\u00e7 kesiciler i\u00e7in elektronik trip \u00fcniteleri<\/strong><\/td>\n<td>88(B)<\/td>\n<td>Elektronikler g\u00fcvenilir \u015fekilde yeniden ko\u015fulland\u0131r\u0131lamaz; yenisi ile de\u011fi\u015ftirilmelidir<\/td>\n<\/tr>\n<tr>\n<td><strong>Panel panolar\u0131<\/strong><\/td>\n<td>8(A)<\/td>\n<td>Yeniden ko\u015fulland\u0131rma sonras\u0131 yap\u0131sal b\u00fct\u00fcnl\u00fck ve bus ba\u011flant\u0131lar\u0131 do\u011frulanamaz<\/td>\n<\/tr>\n<tr>\n<td><strong>Transfer anahtarlar\u0131 (acil durum sistemleri)<\/strong><\/td>\n<td>5(C), 701.5(C), 702.5(A)<\/td>\n<td>Hayat-kurtar\u0131c\u0131 uygulamalar yeni ekipman gerektirir<\/td>\n<\/tr>\n<tr>\n<td><strong>Yang\u0131n pompas\u0131 kontrol\u00f6rleri<\/strong><\/td>\n<td>695.10<\/td>\n<td>Kritik hayat-kurtar\u0131c\u0131 ekipman<\/td>\n<\/tr>\n<tr>\n<td><strong>Prizler ve ba\u011flant\u0131 fi\u015fleri<\/strong><\/td>\n<td>3(A), 406.7<\/td>\n<td>A\u015f\u0131nma ve kontak bozulmas\u0131 g\u00fcvenilir \u015fekilde tespit edilemez<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>MCCB'ler hakk\u0131nda vurgulama: Daha \u00f6nce NEMA AB 4 standartlar\u0131na g\u00f6re baz\u0131 denetim ve \u00f6nleyici bak\u0131m uygulamalar\u0131na izin verilmi\u015f olsa da, kal\u0131pl\u0131 kutu devre kesicilerin yeniden ko\u015fulland\u0131r\u0131lmas\u0131 NEC'in 2020 son bask\u0131s\u0131nda yasaklanm\u0131\u015ft\u0131r. Bak\u0131m (temizlik, \u00e7al\u0131\u015ft\u0131rma, tork kontrol\u00fc) ge\u00e7erlili\u011fini korur ancak kal\u0131pl\u0131 kutu devre kesicilerin i\u00e7 yap\u0131s\u0131n\u0131n s\u00f6k\u00fclmesi ve yeniden montaj\u0131 yasakt\u0131r.<\/p>\n<h2>Devre Kesici Yeniden Ko\u015fulland\u0131rmay\u0131 Destekleyen Markalar<\/h2>\n<p>Farkl\u0131 tan\u0131nm\u0131\u015f \u00fcreticiler, fabrikalar\u0131 taraf\u0131ndan yetkilendirilmi\u015f yeniden ko\u015fulland\u0131rma programlar\u0131n\u0131 y\u00f6netir. Ba\u015fka \u015firketler ad\u0131na \u00e7al\u0131\u015fan yenileme firmalar\u0131 kullan\u0131lmaz.<\/p>\n<table>\n<thead>\n<tr>\n<th>Marka<\/th>\n<th>Program Ad\u0131<\/th>\n<th>Kapsam<\/th>\n<th>Garanti<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Eaton<\/strong><\/td>\n<td>S\u0131n\u0131f 1 Yeniden Ko\u015fulland\u0131rma (G\u00fc\u00e7 Kesici Yeniden Ko\u015fulland\u0131rma Merkezleri)<\/td>\n<td>Eaton ve Eaton d\u0131\u015f\u0131 LV\/MV g\u00fc\u00e7 kesiciler; Magnum DS yeniden \u00fcretimi; VCP-W FAME y\u00fckseltmeleri<\/td>\n<td>3 y\u0131l (motor ba\u015flat\u0131c\u0131 uygulamalar\u0131 i\u00e7in 1 y\u0131l)<\/td>\n<\/tr>\n<tr>\n<td><strong>ABB<\/strong><\/td>\n<td>Servis Merkezi Kesici Yenileme<\/td>\n<td>ABB ve ABB d\u0131\u015f\u0131 kesiciler; n\u00fckleer ve n\u00fckleer olmayan; LV ve MV<\/td>\n<td>1 y\u0131l par\u00e7a ve i\u015f\u00e7ilik<\/td>\n<\/tr>\n<tr>\n<td><strong>Schneider Electric \/ Square D<\/strong><\/td>\n<td>Modernizasyon \u00c7\u00f6z\u00fcmleri \/ Devre Kesici Yeniden Ko\u015fulland\u0131rma<\/td>\n<td>Square D ve \u00e7o\u011fu b\u00fcy\u00fck OEM markas\u0131; LV ve MV kesiciler; \u015falt donan\u0131m\u0131 modernizasyonu<\/td>\n<td>Kapsama g\u00f6re de\u011fi\u015fir<\/td>\n<\/tr>\n<tr>\n<td><strong>Siemens<\/strong><\/td>\n<td>Servis &amp; Yeniden Ko\u015fulland\u0131rma Programlar\u0131<\/td>\n<td>Siemens ve eski markalar (ITE, Gould); LV ve MV g\u00fc\u00e7 kesiciler<\/td>\n<td>Programa g\u00f6re de\u011fi\u015fir<\/td>\n<\/tr>\n<tr>\n<td><strong>GE \/ Vertiv<\/strong><\/td>\n<td>Yeniden Ko\u015fulland\u0131rma Hizmetleri<\/td>\n<td>GE kesiciler ve eski markalar; MV ve HV kesiciler<\/td>\n<td>Programa g\u00f6re de\u011fi\u015fir<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Her Markan\u0131n Teklifi<\/h3>\n<p>Kuzey Amerika b\u00f6lgesinde Eaton, be\u015f G\u00fc\u00e7 Kesici Yeniden Ko\u015fulland\u0131rma Merkezi kurmu\u015ftur. S\u0131n\u0131f 1 protokolleri, par\u00e7alar\u0131n tam s\u00f6k\u00fclmesini, bile\u015fen standartlar\u0131na uygun temizlik, y\u00fczey yenileme ve nihai performans testini i\u00e7erir. Ayr\u0131ca baz\u0131 orta voltaj kesiciler i\u00e7in FAME y\u00fckseltme konseptini ve Digitrip RMS trip \u00fcnitesi ile Ark Fla\u015f Azaltma Bak\u0131m Sisteminin devre kesicilere retrofitini geli\u015ftirmi\u015flerdir. Her yeniden ko\u015fulland\u0131r\u0131lm\u0131\u015f kesici merkezi Pow-R-DB veritaban\u0131na eklenir.<\/p>\n<p>Servis merkezlerinde, ABB hem kendi devre kesici modelleri hem de di\u011fer \u00fcreticilerin modelleri i\u00e7in yeniden test hizmetleri sunmaktad\u0131r. Hizmetleri, ekipman\u0131n al\u0131nmas\u0131, incelenmesi ve test edilmesi ile par\u00e7alar\u0131n\u0131n s\u00f6k\u00fclmesini i\u00e7erir. T\u00fcm par\u00e7alar\u0131n temizlenmesinin yan\u0131 s\u0131ra, ABB \u00e7atlak kontrol\u00fc yapacak, zaten hasar g\u00f6rm\u00fc\u015f par\u00e7alar\u0131n de\u011fi\u015ftirilmesini sa\u011flayacak, t\u00fcm hareketli noktalar\u0131n ya\u011flanmas\u0131n\u0131 uygulayacak ve ard\u0131ndan yeniden monte edecektir.<\/p>\n<p>Modernizasyon \u00c7\u00f6z\u00fcmleri program\u0131nda, Schneider Electric d\u00fc\u015f\u00fck ve orta gerilim g\u00fc\u00e7 devre kesicilerinin yeniden yap\u0131land\u0131r\u0131lmas\u0131 hizmetini davet etmi\u015ftir. Yeniden kondisyona alma, bile\u015fenlerin k\u0131smi de\u011fi\u015ftirilmesi, detaylar\u0131n y\u0131kanmas\u0131 ve boyanmas\u0131 ile ya\u011flama dahil olmak \u00fczere t\u00fcm a\u015famalar kullan\u0131larak ger\u00e7ekle\u015ftirilir.<\/p>\n<h2>Ana Standartlar: NEC, NEMA AB 4, IEEE C37.59 &amp; UL 489<\/h2>\n<p>Birden fazla standart y\u00f6netir <strong>devre kesici yeniden kondisyona alma<\/strong>. Durumunuza hangi standard\u0131n uyguland\u0131\u011f\u0131n\u0131 anlamak, kod uyumlulu\u011fu i\u00e7in esast\u0131r:<\/p>\n<table>\n<thead>\n<tr>\n<th>Standart<\/th>\n<th>Yay\u0131nc\u0131<\/th>\n<th>Kapsam<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>NEC Madde 210.15 &amp; 240.88<\/strong><\/td>\n<td>NFPA<\/td>\n<td>Yeniden \u015fartland\u0131r\u0131labilecek ve \u015fartland\u0131r\u0131lamayacaklar\u0131 tan\u0131mlar; \u201cyeniden \u015fartland\u0131r\u0131lm\u0131\u015f\u201d olarak listeleme gerektirir\u201d<\/td>\n<\/tr>\n<tr>\n<td><strong>NEMA AB 4<\/strong><\/td>\n<td>NEMA<\/td>\n<td>Kal\u0131pl\u0131 kutu kesicilerin (yeniden \u015fartland\u0131rma de\u011fil) muayene ve \u00f6nleyici bak\u0131m\u0131na y\u00f6nelik y\u00f6nergeler<\/td>\n<\/tr>\n<tr>\n<td><strong>IEEE C37.59<\/strong><\/td>\n<td>IEEE<\/td>\n<td>G\u00fc\u00e7 anahtarlama ekipmanlar\u0131n\u0131n yeniden \u015fartland\u0131r\u0131lmas\u0131 i\u00e7in standart; yeniden \u015fartland\u0131rma s\u00fcrecini tan\u0131mlar<\/td>\n<\/tr>\n<tr>\n<td><strong>UL 489<\/strong><\/td>\n<td>UL<\/td>\n<td>Kal\u0131pl\u0131 kutu devre kesiciler i\u00e7in standart; test k\u0131yaslama \u00f6l\u00e7\u00fct\u00fc olarak ge\u00e7erlidir<\/td>\n<\/tr>\n<tr>\n<td><strong>Yeniden \u015eartland\u0131r\u0131lm\u0131\u015f Ekipmanlar i\u00e7in NEMA Politikas\u0131<\/strong><\/td>\n<td>NEMA<\/td>\n<td>Yeniden \u015fartland\u0131r\u0131lm\u0131\u015f ekipmanlar\u0131n uygunlu\u011fu ve g\u00fcvenli\u011fi konusundaki sekt\u00f6r pozisyonlar\u0131<\/td>\n<\/tr>\n<tr>\n<td><strong>PEARL Standartlar\u0131<\/strong><\/td>\n<td>PEARL<\/td>\n<td>Elektrik cihazlar\u0131n\u0131n muayene, test ve yeniden \u015fartland\u0131r\u0131lmas\u0131 i\u00e7in ANSI onayl\u0131 standartlar<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Temel fakt\u00f6r: ilk i\u015faretleme kald\u0131r\u0131lmal\u0131 ve ekipman yenilenirken yeniden \u015fartland\u0131r\u0131lm\u0131\u015f olarak tan\u0131mlanmal\u0131d\u0131r. UL, yeniden yap\u0131land\u0131r\u0131lm\u0131\u015f ekipmanlar i\u00e7in bir sertifikasyon prosed\u00fcr\u00fc sa\u011flar. Prosed\u00fcre uygun olarak yenilenen cihazlar, \u201cRebuilt,\u201d \u201cRemanufactured,\u201d \u201cRebuilt\u201d veya \u201cReconditioned\u201d kelimelerini i\u00e7eren UL Markas\u0131 ile i\u015faretlenir. Kesici standartlar\u0131 hakk\u0131nda daha fazla bilgi i\u00e7in makalemize bak\u0131n\u0131z <a href=\"https:\/\/huyuglobal.com\/tr\/blog\/what-is-ul-489-breakers\/\">UL 489 kesici gereksinimleri<\/a>.<\/p>\n<h2>Yeniden \u015eartland\u0131rma S\u00fcreci Ad\u0131m Ad\u0131m<\/h2>\n<p>Eaton Class 1 ve IEEE C37.59\u2019a g\u00f6re, devre kesicinin yeniden \u015fartland\u0131r\u0131lmas\u0131 gerekti\u011finde izlenen s\u00fcre\u00e7 \u015fudur:<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3575\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/08\/The-Reconditioning-Process-Step-by-Step.webp\" alt=\"Yeniden \u015eartland\u0131rma S\u00fcreci Ad\u0131m Ad\u0131m\" width=\"1448\" height=\"1086\" \/><\/p>\n<h3>Ad\u0131m 1: Giri\u015f Muayenesi ve Testi<\/h3>\n<p>Kesici teslim al\u0131n\u0131r, g\u00f6rsel olarak incelenir ve \u201cal\u0131nd\u0131\u011f\u0131 gibi\u201d durumda test edilerek temel performans belgelenir. Al\u0131nan \u00f6nemli \u00f6l\u00e7\u00fcmler aras\u0131nda kontak direnci (mV cinsinden), yal\u0131t\u0131m direnci, mekanik i\u015fletme kuvveti ve boyutlar yer al\u0131r. Elde edilen bilgiler belgelenir.<\/p>\n<h3>Ad\u0131m 2: Tam S\u00f6k\u00fcm<\/h3>\n<p>Kesicinin s\u00f6k\u00fcm\u00fc tamamlan\u0131r ve i\u015fletme sistemi, ark s\u00f6n\u00fcmleyici, yal\u0131t\u0131m bariyeri, \u00e7er\u00e7eve ve di\u011fer sistemler dahil olmak \u00fczere bile\u015fenlerine ayr\u0131l\u0131r. Bu a\u015famada, ar\u0131zal\u0131 tahrik ba\u011flant\u0131s\u0131, hizalanmam\u0131\u015f kontaklar, ar\u0131za tespit edildi\u011finde cihaz\u0131n tamam\u0131n\u0131 ar\u0131zaya a\u00e7\u0131k hale getiren hasarl\u0131 yal\u0131t\u0131m gibi kusurlar tespit edilir.<\/p>\n<h3>Ad\u0131m 3: Bile\u015fenlere \u00d6zel Temizlik<\/h3>\n<p>Farkl\u0131 malzeme t\u00fcrleri farkl\u0131 temizlik i\u015flemleri gerektirir. Ak\u0131m ta\u015f\u0131mayan bile\u015fenler, dielektrik ve yap\u0131sal \u00f6zellikler korunarak hi\u00e7bir yabanc\u0131 madde kalmayacak \u015fekilde titizlikle temizlenir. Ak\u0131m ta\u015f\u0131yan bile\u015fenler, orijinal kaplamaya zarar vermeden temizlenir. Kontak y\u00fczeyleri, metalurji ve kontak bas\u0131nc\u0131n\u0131n do\u011fru i\u015flev g\u00f6rmesi i\u00e7in yenilenir.<\/p>\n<h3>Ad\u0131m 4: Muayene ve Par\u00e7a De\u011fi\u015fimi<\/h3>\n<p>T\u00fcm par\u00e7alar \u00e7atlak, bozulma, pas ve boyut do\u011frulu\u011fu a\u00e7\u0131s\u0131ndan kontrol edilmelidir. A\u015f\u0131nm\u0131\u015f par\u00e7alar yeni OEM par\u00e7alar\u0131 ile de\u011fi\u015ftirilirken, \u00fcretimi sona ermi\u015f par\u00e7alar IEEE C37.59\u2019da belirtilen standartlara uygun tersine m\u00fchendislik bile\u015fenleri ile de\u011fi\u015ftirilmelidir. Bu t\u00fcr bile\u015fenler, y\u00fcksek g\u00fc\u00e7 testleri gibi s\u0131k\u0131 laboratuvar ko\u015fullar\u0131nda do\u011frulama gerektirebilir. A\u015f\u0131nm\u0131\u015f par\u00e7alar\u0131n tipik yedekleri yaylar, kontaklar, \u015f\u00f6ntler ve bur\u00e7lar olabilir.<\/p>\n<h3>Ad\u0131m 5: Yeniden Ya\u011flama<\/h3>\n<p>T\u00fcm eski ya\u011flay\u0131c\u0131lar elimine edilmi\u015f ve makine ile ba\u011flant\u0131 noktalar\u0131 \u00fcretici taraf\u0131ndan belirtilen gres ile yeniden ya\u011flanm\u0131\u015ft\u0131r. Devre kesicilerin ar\u0131zalanmas\u0131n\u0131n temel nedenlerinden biri uygunsuz ya\u011flamad\u0131r \u2014 sert mekanizmalar ar\u0131za giderme s\u00fcrecini yava\u015flat\u0131r, bu da \u00e7ok daha y\u00fcksek ark fla\u015f olay\u0131 enerjisine yol a\u00e7ar.<\/p>\n<h3>Ad\u0131m: OEM Spesifikasyonlar\u0131na G\u00f6re Yeniden Montaj<\/h3>\n<p>Kesicinin yeniden montaj\u0131 s\u00fcrecinde OEM dok\u00fcmantasyonu kullan\u0131l\u0131r. Ancak, OEM bilgisi mevcut de\u011filse, \u00f6rne\u011fin orijinal \u00fcretici faaliyette de\u011filse, Eaton istenen sonu\u00e7lar\u0131 verdi\u011fi kan\u0131tlanm\u0131\u015f benzer kesicilerin kay\u0131tlar\u0131n\u0131n merkezi Pow-R-DB veritaban\u0131n\u0131 kullan\u0131r.<\/p>\n<h3>Ad\u0131m: Nihai Test<\/h3>\n<p>Yeniden yap\u0131land\u0131r\u0131lm\u0131\u015f devre kesici IEEE ve NEMA y\u00f6nergelerine g\u00f6re a\u015fa\u011f\u0131daki kesin testlerden ge\u00e7er:<\/p>\n<ul>\n<li>\u0130zolasyon direnci de\u011ferlendirmesi<\/li>\n<li>Kontakt direnci testi (milyonvolt d\u00fc\u015f\u00fcm\u00fc)<\/li>\n<li>Mekanik \u00e7al\u0131\u015fma de\u011ferlendirmesi (a\u00e7ma-kapama zamanlamas\u0131)<\/li>\n<li>A\u015f\u0131r\u0131 ak\u0131m trip testi (uzun s\u00fcreli, k\u0131sa s\u00fcreli, anl\u0131k trip)<\/li>\n<li>Dielektrik dayan\u0131m de\u011ferlendirmesi<\/li>\n<\/ul>\n<h3>Ad\u0131m: Dok\u00fcmantasyon ve Etiketleme<\/h3>\n<p>\u201cAl\u0131nd\u0131\u011f\u0131 hali\u201d ile \u201cnihai\u201d test sonu\u00e7lar\u0131 aras\u0131nda kar\u015f\u0131la\u015ft\u0131rma yapmak i\u00e7in test raporu haz\u0131rlan\u0131r ve t\u00fcm onar\u0131lan bile\u015fenleri belirten bilgilerle desteklenir. Devre kesici, yeniden kondisyona al\u0131nd\u0131\u011f\u0131n\u0131 g\u00f6steren ve yeniden kondisyona alma firmas\u0131n\u0131n ad\u0131n\u0131 ve tarihini i\u00e7eren izlenebilirlik etiketi ile donat\u0131l\u0131r. Devre kesici tekrar \u00e7al\u0131\u015f\u0131r durumdad\u0131r.<\/p>\n<h2>Yeniden Kondisyona Alma m\u0131 Yoksa De\u011fi\u015ftirme mi Se\u00e7ilmeli?<\/h2>\n<p>Yeniden kondisyona alma veya de\u011fi\u015ftirme karar\u0131 kesici tipi, ya\u015f\u0131, kritikli\u011fi ve maliyete ba\u011fl\u0131d\u0131r. \u0130\u015fte pratik bir karar matrisi:<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3576\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/08\/When-to-Choose-Reconditioning-vs-Replacement.webp\" alt=\"Yeniden Kondisyona Alma m\u0131 Yoksa De\u011fi\u015ftirme mi Se\u00e7ilmeli?\" width=\"1448\" height=\"1086\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Senaryo<\/th>\n<th>\u00d6neri<\/th>\n<th>Gerek\u00e7e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Anahtarlama cihaz\u0131nda 15\u201330 ya\u015f aras\u0131 LV\/MV g\u00fc\u00e7 devre kesici<\/td>\n<td><strong>Yeniden kondisyona alma<\/strong><\/td>\n<td>Bak\u0131m i\u00e7in tasarlanm\u0131\u015f; OEM par\u00e7alar\u0131 mevcut; 40\u201360% yeni olandan daha ucuz<\/td>\n<\/tr>\n<tr>\n<td>Eski trip \u00fcnitesine sahip g\u00fc\u00e7 kesici<\/td>\n<td><strong>Yeniden kondisyona alma + trip y\u00fckseltme<\/strong><\/td>\n<td>Yeni kat\u0131 hal trip \u00fcnitesi \u00f6mr\u00fc uzat\u0131r ve ark fla\u015f azaltma \u00f6zellikleri ekler<\/td>\n<\/tr>\n<tr>\n<td>Ar\u0131zalanan panel panosundaki MCCB<\/td>\n<td><strong>De\u011fi\u015ftir<\/strong><\/td>\n<td>NEC, MCCB yenilemesini yasaklar; de\u011fi\u015ftirme tek kod uyumlu se\u00e7enektir<\/td>\n<\/tr>\n<tr>\n<td>GFCI veya AFCI kesici<\/td>\n<td><strong>De\u011fi\u015ftir<\/strong><\/td>\n<td>NEC 210.15 g\u00fcvenlik cihazlar\u0131n\u0131n yenilenmesini a\u00e7\u0131k\u00e7a yasaklar<\/td>\n<\/tr>\n<tr>\n<td>\u015eiddetli ark hasarl\u0131 g\u00fc\u00e7 kesici<\/td>\n<td><strong>De\u011fi\u015ftir<\/strong><\/td>\n<td>Geni\u015f hasar yap\u0131sal b\u00fct\u00fcnl\u00fc\u011f\u00fc tehlikeye atabilir; yenileme maliyeti de\u011fi\u015ftirmeyi a\u015fabilir<\/td>\n<\/tr>\n<tr>\n<td>Modernizasyona ihtiya\u00e7 duyan \u015falt donan\u0131m\u0131 serisi<\/td>\n<td><strong>Kesicileri yenile + retrofill<\/strong><\/td>\n<td>\u015ealt donan\u0131m\u0131 \u00f6mr\u00fcn\u00fc tamamen de\u011fi\u015ftirmeden uzat\u0131r; kesinti s\u00fcresini minimize eder<\/td>\n<\/tr>\n<tr>\n<td>Acil durum sistemi veya ya\u015fam g\u00fcvenli\u011fi devresi<\/td>\n<td><strong>Yenisi ile de\u011fi\u015ftir<\/strong><\/td>\n<td>Sigorta ve kod gereksinimleri kritik devreler i\u00e7in yeni ekipman zorunlu k\u0131labilir<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Kesicinizin ger\u00e7ekten bak\u0131m gerektirip gerektirmedi\u011fini te\u015fhis etmek i\u00e7in yard\u0131m almak \u00fczere rehberimize bak\u0131n <a href=\"https:\/\/huyuglobal.com\/tr\/blog\/how-to-tell-if-a-breaker-is-bad\/\">bir devre kesicinin bozuk olup olmad\u0131\u011f\u0131n\u0131 nas\u0131l anlayaca\u011f\u0131n\u0131z<\/a>. Ve e\u011fer de\u011fi\u015ftirme do\u011fru karar ise, makalemiz <a href=\"https:\/\/huyuglobal.com\/tr\/blog\/how-much-to-replace-a-circuit-breaker\/\">bir devre kesicinin de\u011fi\u015ftirme maliyeti ne kadar olur<\/a> kesici tipleri ve amperaj derecelendirmeleri aras\u0131nda fiyatland\u0131rmay\u0131 kapsar.<\/p>\n<h2>Maliyet Kar\u015f\u0131la\u015ft\u0131rmas\u0131: Yenilenmi\u015f vs. Yeni<\/h2>\n<p>Devre kesicilerin yenilenmesi s\u00f6z konusu oldu\u011funda, giderler genellikle yeni ekipman al\u0131m maliyetinin ile aras\u0131nda de\u011fi\u015fir. Bu \u00f6zellikle b\u00fcy\u00fck modeller i\u00e7in ge\u00e7erlidir ve \u00e7ok para tasarrufu sa\u011flar:<\/p>\n<table>\n<thead>\n<tr>\n<th>Kesici T\u00fcr\u00fc<\/th>\n<th>Yeni Maliyet (Yakla\u015f\u0131k)<\/th>\n<th>Yenilenmi\u015f Maliyet (Yakla\u015f\u0131k)<\/th>\n<th>Tasarruf<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>LV g\u00fc\u00e7 kesici, 800A \u00e7er\u00e7eve<\/td>\n<td>000\u201315.000<\/td>\n<td>200\u20139.000<\/td>\n<td>40\u201360%<\/td>\n<\/tr>\n<tr>\n<td>LV g\u00fc\u00e7 kesici, 3200A \u00e7er\u00e7eve<\/td>\n<td>000\u201340.000<\/td>\n<td>000\u201324.000<\/td>\n<td>40\u201360%<\/td>\n<\/tr>\n<tr>\n<td>MV vakum kesici, 5kV<\/td>\n<td>000\u201330.000<\/td>\n<td>000\u201318.000<\/td>\n<td>40\u201360%<\/td>\n<\/tr>\n<tr>\n<td>MV vakum kesici, 15kV<\/td>\n<td>000\u201350.000<\/td>\n<td>000\u201330.000<\/td>\n<td>40\u201360%<\/td>\n<\/tr>\n<tr>\n<td>Trip \u00fcnitesi y\u00fckseltmesi (Digitrip\/AC-PRO)<\/td>\n<td>000\u20138.000<\/td>\n<td>Yenileme i\u00e7inde dahil<\/td>\n<td>Paket tasarruflar\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Ek giderler: Yenileme s\u00fcreci, yeni bir kesicinin boyut de\u011fi\u015fikli\u011fi durumunda gerekli olacak \u015falt donan\u0131m\u0131 modifikasyon maliyetlerini azalt\u0131r, yenilenmi\u015f kesiciler 2-4 hafta i\u00e7inde gelirken yenilerinin teslim s\u00fcresi 12-20 hafta oldu\u011fundan teslim s\u00fcresini minimize eder ve yenilenmi\u015f kesici mevcut h\u00fccrede hemen uygulanabildi\u011fi i\u00e7in duru\u015f s\u00fcresini azalt\u0131r.<\/p>\n<h2 id=\"safety\">G\u00fcvenlik Hususlar\u0131 ve Dok\u00fcmantasyon Gereksinimleri<\/h2>\n<p>Yenileme yaln\u0131zca kabul edilen standartlara uygun sertifikal\u0131 personel taraf\u0131ndan yap\u0131labilir. Yenilenmi\u015f bir devre kesicinin kurulumu \u00f6ncesinde kontrol edilmesi gereken gereksinimler \u015funlard\u0131r:<\/p>\n<ul>\n<li>Etiketleme: Yenilenmi\u015f devre kesicisi \u201cYenilenmi\u015f\u201d olarak, yenileme \u015firketinin ad\u0131 ve tarih ile i\u015faretlenmi\u015ftir.<\/li>\n<li>Test: \u201cAl\u0131nd\u0131\u011f\u0131 gibi\u201d ve \u201cson\u201d test sonu\u00e7lar\u0131n\u0131 ve de\u011fi\u015ftirilen par\u00e7alar\u0131n listesini i\u00e7eren tam bir rapor al\u0131n.<\/li>\n<li>Sertifikasyon: UL sertifikas\u0131 gerekiyorsa, devre kesicinin UL Markas\u0131 ile \u201cYeniden Yap\u0131lm\u0131\u015f\u201d veya \u201cYenilenmi\u015f\u201d olarak i\u015faretlendi\u011fini do\u011frulay\u0131n.\u201d<\/li>\n<li>AHJ Onay\u0131: Yetkili Denetleyici (elektrik m\u00fcfetti\u015fi) sertifikal\u0131 bir \u015firket taraf\u0131ndan yenileme kan\u0131t\u0131 isteyebilir \u2013 haz\u0131rl\u0131kl\u0131 olun.<\/li>\n<li>Garanti: Garanti ko\u015fullar\u0131n\u0131 ve s\u00fcresini do\u011frulay\u0131n (Eaton: 3 y\u0131l; ABB: 1 y\u0131l; di\u011ferleri de\u011fi\u015fken).<\/li>\n<li>\u0130zlenebilirlik: Yenileme \u015firketi, gelecekteki referanslar i\u00e7in devre kesici seri numaras\u0131yla ba\u011flant\u0131l\u0131 kay\u0131t tutmal\u0131d\u0131r.<\/li>\n<li>Yenilenmi\u015f devre kesiciyi, AHJ ve sigorta acenteniz kurulumu onaylamad\u0131k\u00e7a ya\u015fam g\u00fcvenli\u011fi devresine takmay\u0131n.<\/li>\n<\/ul>\n<p>Ayr\u0131ca, OSHA 29 CFR 1910.334(b)(2) koruyucu cihazla devre enerjisi kesildikten sonra, ekipman ve devrenin g\u00fcvenli \u015fekilde enerjilendirilebilece\u011fi belirlenene kadar manuel olarak yeniden enerjilendirilmesine izin verilmedi\u011fini belirtir.<\/p>\n<h2>S\u0131k\u00e7a Sorulan Sorular<\/h2>\n<h3>Yenilenmi\u015f devre kesici nedir?<\/h3>\n<p>Yenilenmi\u015f bir g\u00fc\u00e7 devre kesicisi, fabrika yetkili bir tesiste restorasyon s\u00fcrecinden ge\u00e7mi\u015f bir g\u00fc\u00e7 devre kesicisini ifade eder. IEEE C37.59 taraf\u0131ndan belirlenen gereksinimlere g\u00f6re, t\u00fcm faaliyetler gelen muayene, tam s\u00f6k\u00fcm, bile\u015fenlerin temizlenmesi, par\u00e7alar\u0131n de\u011fi\u015ftirilmesi, ya\u011flay\u0131c\u0131lar\u0131n yeniden uygulanmas\u0131, OEM spesifikasyonlar\u0131na g\u00f6re bile\u015fenlerin yeniden montaj\u0131 ve son testleri i\u00e7erir. Ayr\u0131ca, devre kesici yenilenmi\u015f olarak etiketlenmeli ve yenileme firmas\u0131n\u0131n ad\u0131 ve tarihi belirtilmelidir; orijinal listeleme NEC gereksinimleri nedeniyle kald\u0131r\u0131lm\u0131\u015f olmal\u0131d\u0131r.<\/p>\n<h3>Tip B, tip C ve tip D devre kesiciler nedir?<\/h3>\n<p>Tip B, C ve D, MCB'lerin a\u00e7ma karakteristikleri ile ilgili s\u0131n\u0131fland\u0131rmalard\u0131r ve NEC 240.88'e g\u00f6re s\u0131n\u0131fland\u0131r\u0131lm\u0131\u015f devre kesici tipleri de\u011fildir. Tip B devre kesiciler, nominal ak\u0131m\u0131n \u00fc\u00e7 ila be\u015f kat\u0131nda a\u00e7ma yapar; bunlar tamamen diren\u00e7li y\u00fcklerin bulundu\u011fu konut uygulamalar\u0131nda kullan\u0131l\u0131r. Ard\u0131ndan, nominal ak\u0131m\u0131n be\u015f ila on kat\u0131nda a\u00e7ma yapan Tip C devre kesiciler gelir ve ticari ve end\u00fcstriyel elektrik sistemlerinde, ayr\u0131ca floresan lambalar ve k\u00fc\u00e7\u00fck motorlar gibi end\u00fcktif y\u00fcklerin bulundu\u011fu devrelerde kullan\u0131l\u0131r. \u00dc\u00e7\u00fcnc\u00fc tip ise, nominal ak\u0131m\u0131n on ila yirmi kat\u0131nda a\u00e7ma yapan Tip D MCB'lerdir ve trafolar, b\u00fcy\u00fck motorlar veya kaynak makinelerindeki giri\u015f ak\u0131m\u0131 ile ba\u015fa \u00e7\u0131karlar. Yukar\u0131daki t\u00fcm devre kesici tipleri minyat\u00fcr devre kesiciler olup, kal\u0131pl\u0131 kutulu ve NEC 240.88(A)(1) uyar\u0131nca yenilenemezler.<\/p>\n<h3>Kal\u0131pl\u0131 kutulu devre kesicilerin yenilenmesine izin veriliyor mu?<\/h3>\n<p>2020 y\u0131l\u0131 NEC B\u00f6l\u00fcm 240.88(A)(1) uyar\u0131nca, kal\u0131pl\u0131 kutulu devre kesicilerin yenilenmesine izin verilmemektedir. MCCB'ler m\u00fch\u00fcrl\u00fc \u00fcnite olarak gelir, bu nedenle m\u00fch\u00fcrlerin k\u0131r\u0131lmas\u0131 UL listelemesinin ve \u00fcretici garantisinin kayb\u0131 anlam\u0131na gelir. NEMA AB 4 y\u00f6nergelerinde MCCB'lerin muayenesi ve \u00f6nleyici bak\u0131m\u0131 i\u00e7in rehberlik bulunmas\u0131na ra\u011fmen, bu yenileme ile e\u015fde\u011fer de\u011fildir. Rutin bak\u0131m kabul edilir ancak MCCB'nin i\u00e7 yap\u0131s\u0131n\u0131n s\u00f6k\u00fclmesi veya de\u011fi\u015ftirilmesi kabul edilmez.<\/p>\n<h3>Madde 210'a g\u00f6re hangi t\u00fcr ekipman\u0131n yenilenmesine izin verilmemektedir?<\/h3>\n<p>NEC, Madde 210.15 kapsam\u0131nda, yeniden kondisyona sokulmas\u0131na izin verilmeyen \u00fc\u00e7 t\u00fcr ekipman oldu\u011funu belirtir. Bunlar \u015funlar\u0131 i\u00e7erir: (1) personele toprak ka\u00e7ak devre kesici (GFCI) korumas\u0131 sa\u011flayan ekipman, (2) ark ka\u00e7ak devre kesici (AFCI) korumas\u0131 sa\u011flayan ekipman ve (3) ekipman i\u00e7in toprak ka\u00e7ak korumas\u0131 (GFPE) sa\u011flayan ekipman. Bu yasaklar\u0131n nedeni, yeniden kondisyona sokulmas\u0131 gereken cihazlar\u0131n ayn\u0131 zamanda kalibrasyon ve hassasiyet gereksinimlerine sahip olan ve yeniden kondisyona sokulduktan sonra bile bu gereksinimlerin garanti edilemedi\u011fi kritik g\u00fcvenlik cihazlar\u0131 olmalar\u0131d\u0131r. B\u00f6ylece, yeniden kondisyona sokulan herhangi bir cihaz (GFCI, AFCI veya GFPE) gerekli e\u015fik de\u011ferinde devreyi a\u00e7mazsa, ya\u015fam tehlikesi olu\u015facakt\u0131r. Ayr\u0131ca, NEC, Madde 240.88(A)(1) kapsam\u0131nda kal\u0131pl\u0131 devre kesicilerin yeniden kondisyona sokulamayaca\u011f\u0131n\u0131 ve Madde 240.88(B) uyar\u0131nca d\u00fc\u015f\u00fck voltajl\u0131 g\u00fc\u00e7 devre kesicilerinin elektronik trip \u00fcnitelerinin de yeniden kondisyona sokulamayaca\u011f\u0131n\u0131 belirtir.<\/p>\n<h2>Referanslar<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" target=\"_blank\" rel=\"nofollow noopener\">NFPA 70 \u2014 Ulusal Elektrik Kodu (NEC) 2020, Maddeler 210.15 ve 240.88<\/a><\/li>\n<li><a href=\"https:\/\/www.nema.org\/standards\/view\/guidelines-for-inspection-and-preventive-maintenance-of-molded-case-circuit-breakers-used-in-commercial-and-industrial\" target=\"_blank\" rel=\"nofollow noopener\">ANSI\/NEMA AB 4-2023 \u2014 Kal\u0131pl\u0131 Kasa Devre Kesicilerin Muayene ve \u00d6nleyici Bak\u0131m K\u0131lavuzlar\u0131<\/a><\/li>\n<li><a href=\"https:\/\/standards.ieee.org\/ieee\/C37.59\/10366\/\" target=\"_blank\" rel=\"nofollow noopener\">IEEE C37.59-2018 \u2014 G\u00fc\u00e7 Anahtarlama Ekipmanlar\u0131n\u0131n Yeniden Kondisyona Sokulmas\u0131 Standard\u0131<\/a><\/li>\n<li><a href=\"https:\/\/www.shopul.com\/product\/ul-489\" target=\"_blank\" rel=\"nofollow noopener\">UL 489 \u2014 Kal\u0131pl\u0131 Kasa Devre Kesiciler, Kal\u0131pl\u0131 Kasa Anahtarlar ve Devre Kesici Muhafazalar\u0131 Standard\u0131<\/a><\/li>\n<li><a href=\"https:\/\/www.ul.com\/news\/reconditioned-electrical-equipment-2020-nec-guide\" target=\"_blank\" rel=\"nofollow noopener\">UL \u2014 Yeniden Kondisyona Sokulmu\u015f Elektrik Ekipmanlar\u0131: 2020 NEC K\u0131lavuzu<\/a><\/li>\n<li><a href=\"https:\/\/www.eaton.com\/us\/en-us\/catalog\/services\/electrical-distribution-services\/class-1-reconditioning.html\" target=\"_blank\" rel=\"nofollow noopener\">Eaton \u2014 D\u00fc\u015f\u00fck ve Orta Voltaj G\u00fc\u00e7 Devre Kesicileri i\u00e7in S\u0131n\u0131f 1 Devre Kesici Yeniden Kondisyon Hizmeti<\/a><\/li>\n<li><a href=\"https:\/\/new.abb.com\/service\/service-centers\/breaker-refurbishment-services\" target=\"_blank\" rel=\"nofollow noopener\">ABB \u2014 Servis Merkezi Devre Kesici Yenileme Hizmetleri<\/a><\/li>\n<li><a href=\"https:\/\/www.se.com\/us\/en\/work\/services\/field-services\/electrical-distribution\/\" target=\"_blank\" rel=\"nofollow noopener\">Schneider Electric \u2014 Elektrik Da\u011f\u0131t\u0131m Modernizasyonu ve Y\u00fckseltme \u00c7\u00f6z\u00fcmleri<\/a><\/li>\n<li><a href=\"https:\/\/www.pearl1.org\/\" target=\"_blank\" rel=\"nofollow noopener\">PEARL \u2014 Profesyonel Elektrik Cihazlar\u0131 Yeniden Kondisyon Birli\u011fi<\/a><\/li>\n<\/ul>\n<p>Yeniden kondisyona sokulabilir devre kesiciler, genellikle trafo merkezlerinde ve anahtarlama ekipmanlar\u0131nda kullan\u0131lan \u00e7ekmeli, saha servis edilebilir tipte d\u00fc\u015f\u00fck, orta ve y\u00fcksek voltaj devre kesicilerini i\u00e7erir. Devre kesicinin tasar\u0131m\u0131, de\u011fi\u015ftirilebilir kontaklar, kolay eri\u015filebilir mekanizma ve de\u011fi\u015ftirilebilir trip \u00fcniteleri kullanarak NEC 240.88 ile uyumlu pratik yeniden kondisyona sokma imkan\u0131 sa\u011flar. Eaton, ABB ve Schneider Electric gibi b\u00fcy\u00fck \u00fcreticiler, IEEE C37.59 standartlar\u0131na uygun olarak yeni ekipman garantileriyle kar\u015f\u0131la\u015ft\u0131r\u0131labilir garantiler sunan yeniden kondisyona sokma hizmeti sa\u011flar.<\/p>\n<p>\u00d6te yandan, kal\u0131pl\u0131 kasa devre kesiciler, GFCI cihazlar\u0131, AFCI cihazlar\u0131 ve GFPE ekipmanlar\u0131 NEC 210.15 ve 240.88 uyar\u0131nca ko\u015fulsuz olarak yeniden kondisyona sokulmas\u0131 yasaklanm\u0131\u015f olup, ar\u0131zaland\u0131klar\u0131nda de\u011fi\u015ftirilmelidir. 2020 NEC, bak\u0131m yap\u0131labilir olarak tasarlanm\u0131\u015f devre kesicilerin bak\u0131m\u0131n\u0131n yap\u0131labilece\u011fini, ancak m\u00fch\u00fcrl\u00fc kritik g\u00fcvenlik devre kesicilerinin yap\u0131lamayaca\u011f\u0131n\u0131 a\u00e7\u0131k\u00e7a belirtmi\u015ftir. Yeniden kondisyona sokma veya de\u011fi\u015ftirme se\u00e7ene\u011fi tercih edilirken, \u00f6nce devre kesici t\u00fcr\u00fc belirlenmeli ve ar\u0131za maliyeti kar\u015f\u0131la\u015ft\u0131r\u0131larak hangi i\u015flemin daha de\u011ferli oldu\u011fu \u2014 yeniden kondisyona sokma m\u0131 yoksa devre kesiciyi de\u011fi\u015ftirme mi \u2014 anla\u015f\u0131lmal\u0131d\u0131r.<\/p>","protected":false},"excerpt":{"rendered":"<p>In case your facility uses outdated switchgears, you may wonder whether you can refurbish your circuit breakers or should obtain brand new gadgets. The answer is not that simple, as it depends on a type of circuit breaker in your facility. As stated by the National Electrical Code (NEC) of 2020, low-voltage power circuit breakers, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3572,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-3571","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/posts\/3571","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/comments?post=3571"}],"version-history":[{"count":3,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/posts\/3571\/revisions"}],"predecessor-version":[{"id":3579,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/posts\/3571\/revisions\/3579"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/media\/3572"}],"wp:attachment":[{"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/media?parent=3571"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/categories?post=3571"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/tags?post=3571"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}