{"id":4237,"date":"2026-09-13T00:52:32","date_gmt":"2026-09-13T00:52:32","guid":{"rendered":"https:\/\/huyuglobal.com\/?p=4237"},"modified":"2026-09-13T00:54:00","modified_gmt":"2026-09-13T00:54:00","slug":"what-is-the-function-of-a-no-volt-release","status":"publish","type":"post","link":"https:\/\/huyuglobal.com\/tr\/blog\/what-is-the-function-of-a-no-volt-release\/","title":{"rendered":"No-Volt Release'\u0131n Fonksiyonu Nedir?"},"content":{"rendered":"<p>No-volt release, her kontrol paneli \u00fcreticisi ve makine tasar\u0131mc\u0131s\u0131n\u0131n bir noktada kendine sormas\u0131 gereken bir soruya cevap sa\u011flar: \u201cG\u00fc\u00e7 kesilip tekrar geldi\u011finde ne olacak?\u201d D\u00f6ner b\u0131\u00e7aklar, y\u00fckl\u00fc konvey\u00f6rler ve bas\u0131n\u00e7 pompalar\u0131 olan makineler i\u00e7in \u201cmakine kendi kendine ba\u015flar\u201d demek kabul edilemez. No-volt release (bazen no-voltage coil veya undervoltage release (UVR) olarak da adland\u0131r\u0131l\u0131r), \u201cBana kapal\u0131 kalmam s\u00f6ylendi\u011fi s\u00fcrece kapal\u0131 kalaca\u011f\u0131m\u201d pozisyonunu korur. Bu cihaz, bir kontrol panelindeki en ucuz g\u00fcvenlik cihaz\u0131 olmas\u0131n\u0131n yan\u0131 s\u0131ra, ayn\u0131 i\u015flevin kontakt\u00f6r veya devre kesici kullan\u0131l\u0131p kullan\u0131lmad\u0131\u011f\u0131na ba\u011fl\u0131 olarak olduk\u00e7a farkl\u0131 yap\u0131lmas\u0131 nedeniyle en \u00e7ok yanl\u0131\u015f anla\u015f\u0131lan cihazlardan biridir. Bu rehber, no-volt release\u2019ler, \u00e7al\u0131\u015fma prensipleri, uygulamalar\u0131, shunt trip\u2019lerden farklar\u0131, alternatifleri, no-volt release ihtiyac\u0131 ve no-volt release\u2019in nas\u0131l spesifiye edilip test edilece\u011fi hakk\u0131nda bilgi i\u00e7erir; b\u00f6ylece bobin voltaj\u0131 tuza\u011f\u0131na d\u00fc\u015fmezsiniz.<\/p>\n<blockquote><p>\u00d6zetlemek gerekirse, no-volt release\u2019in amac\u0131, kontrol voltaj\u0131 sa\u011fland\u0131\u011f\u0131 s\u00fcrece bir anahtarlama cihaz\u0131n\u0131n kapal\u0131 pozisyonda kalmas\u0131n\u0131 sa\u011flamakt\u0131r; kontrol voltaj\u0131 kesildi\u011finde, IEC\/EN 60947-2 standard\u0131na g\u00f6re, kontrol voltaj\u0131 nominal de\u011ferinin \u2019inin alt\u0131na d\u00fc\u015ft\u00fc\u011f\u00fcnde ekipman otomatik olarak a\u00e7\u0131l\u0131r; ile nominal voltaj aral\u0131\u011f\u0131nda otomatik a\u00e7\u0131lma olmaz ve \u2019in \u00fczerinde otomatik a\u00e7\u0131lma ger\u00e7ekle\u015fmez. No-volt release, besleme kayb\u0131 sonras\u0131 ekipman\u0131n otomatik yeniden ba\u015flamas\u0131n\u0131 engeller; \u00e7\u00fcnk\u00fc g\u00fc\u00e7 kesintisi sonras\u0131 g\u00fc\u00e7 nominal de\u011ferinin yakla\u015f\u0131k \u2019ine geri geldi\u011finde yeniden ba\u015flatma ger\u00e7ekle\u015febilir.<\/p><\/blockquote>\n<h2>Temel Fonksiyon<\/h2>\n<p>Bunu tek c\u00fcmleyle ifade etmek gerekirse, no-volt release kontrol voltaj\u0131n\u0131n sa\u011flanmas\u0131n\u0131 kontrol\u00fcn a\u00e7\u0131k kalma ko\u015fulu haline getirir. Ancak d\u00f6rt farkl\u0131 fonksiyon vard\u0131r ve \u00e7e\u015fitli projeler farkl\u0131 fonksiyonlar gerektirece\u011fi i\u00e7in bunlar\u0131n netle\u015ftirilmesi faydal\u0131d\u0131r.<\/p>\n<p><span style=\"color: #ff0000;\">Beklenmeyen Yeniden Ba\u015flatman\u0131n \u00d6nlenmesi.<\/span> Bu, no-volt release\u2019in ana amac\u0131d\u0131r ve ad\u0131n\u0131 buradan al\u0131r. Beslemede bir ar\u0131za oldu\u011funda, bu noktadan sonraki her \u015fey durur. Ancak tehlike, besleme tekrar ba\u015flad\u0131\u011f\u0131 saniyelerden kaynaklan\u0131r. No-volt release\u2019in \u00f6nlemeyi ama\u00e7lad\u0131\u011f\u0131 klasik kaza, bir testere, mikser, konvey\u00f6r veya makine tak\u0131m\u0131n\u0131n operat\u00f6r\u00fcn elleri hala makinenin i\u00e7indeyken tekrar \u00e7al\u0131\u015fmaya ba\u015flamas\u0131d\u0131r. No-volt release, devrenin kapanmas\u0131n\u0131 engeller ve operat\u00f6r\u00fcn ba\u015flatma d\u00fc\u011fmesine basmas\u0131n\u0131 bekler. Bu, makine standartlar\u0131nda bulunmas\u0131 gereken ve end\u00fcstriyel makinelerin \u00e7o\u011fu i\u00e7in zorunlu olan bir \u00f6zelliktir.<\/p>\n<p><span style=\"color: #ff0000;\">S\u00fcrekli Voltaj Alt\u0131nda Otomatik Kapanma Olu\u015fturma.<\/span> Motorlar d\u00fc\u015f\u00fck voltajda iyi \u00e7al\u0131\u015fmazlar. Bireysel motorlar, ayn\u0131 miktarda i\u015f \u00fcretmek i\u00e7in d\u00fc\u015f\u00fck voltajlarda daha fazla elektrik \u00e7eker ve bu da tellerde daha fazla \u0131s\u0131ya neden olur; bu durumda izolasyonun bozulmas\u0131 ve ekipman\u0131n ar\u0131zalanmas\u0131 s\u00f6z konusu olabilir. Undervoltage r\u00f6lesinin (UVR) rol\u00fc, termal ar\u0131za olmamas\u0131 i\u00e7in devreyi a\u00e7makt\u0131r.<\/p>\n<p><span style=\"color: #ff0000;\">Sert Ba\u011flant\u0131l\u0131 Bir G\u00fcvenlik Tahliyesi Olu\u015fturma.<\/span> No-volt release, normal besleme voltaj\u0131 oldu\u011funda voltaj eksikli\u011fine ba\u011fl\u0131 olarak \u00e7al\u0131\u015ft\u0131\u011f\u0131ndan, her g\u00fcvenlik cihaz\u0131 acil kapatma olu\u015fturmak i\u00e7in bir ara\u00e7 olarak kullan\u0131labilir. Bir g\u00fcvenlik anahtar\u0131, \u00e7ekme ipi anahtar\u0131, yang\u0131n alarm anahtar\u0131 veya bina y\u00f6netim sistemi ile temas do\u011fal olarak devrenin a\u00e7\u0131lmas\u0131n\u0131 sa\u011flar. Hatt\u0131 kesen her \u015fey g\u00fcvenli bir kapatma olu\u015fturur. Bu davran\u0131\u015f \u201cfail-safe\u201d olarak bilinir.\u201d<\/p>\n<p><span style=\"color: #ff0000;\">Kapanmadan \u00d6nce Sa\u011fl\u0131kl\u0131 Voltaj\u0131n Onaylanmas\u0131.<\/span> Jenerat\u00f6r transfer \u015femalar\u0131nda, voltaj yoksa anahtar\u0131n kapanmas\u0131nda teredd\u00fct olur. UVR, sa\u011fl\u0131kl\u0131 voltaj\u0131n (nominal voltaj\u0131n \u2019inden fazla) onaylanmas\u0131na izin verir.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4238\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/09\/How-No-Volt-Release-Works.webp\" alt=\"No-Volt Serbest B\u0131rakma Nas\u0131l \u00c7al\u0131\u015f\u0131r\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>Nas\u0131l \u00c7al\u0131\u015f\u0131r<\/h2>\n<p>Kontakt\u00f6r konfig\u00fcrasyonunda prensip \u00e7ok basittir. Enerji, start anahtar\u0131na bas\u0131larak kontakt\u00f6r bobinine sa\u011flan\u0131r ve ana kontaklar kapand\u0131\u011f\u0131nda, start anahtar\u0131na paralel olan yard\u0131mc\u0131, normalde a\u00e7\u0131k bir kontak da kapan\u0131r. Bu yard\u0131mc\u0131 kontak, tutma konta\u011f\u0131 olarak bilinir ve operat\u00f6r d\u00fc\u011fmeyi b\u0131rakt\u0131ktan sonra bobini enerjize etmeye devam eder. Bu nedenle, b\u0131rak\u0131lm\u0131\u015f olsa bile bobin i\u00e7in ak\u0131m yolu vard\u0131r ve devre otomatik olarak korunur; bu durumda bobini bu durumda tutmak i\u00e7in harici enerji kayna\u011f\u0131 gerekmez. Cihaz\u0131 \u00e7al\u0131\u015ft\u0131ran kontrol voltaj\u0131 oldu\u011fundan, bobinin no-volt release olarak hizmet etti\u011fini s\u00f6yleyebiliriz. Devrede ek bir bile\u015fen gerekmez.<\/p>\n<p>Ancak devre kesici ile farkl\u0131 bir durumla kar\u015f\u0131la\u015f\u0131r\u0131z ve \u00e7o\u011fu kar\u0131\u015f\u0131kl\u0131k buradan kaynaklan\u0131r. Devre kesici, mekanik bir mandala dayan\u0131r; bu, devre enerjilendirilmeden kapal\u0131 pozisyonda kalmas\u0131 anlam\u0131na gelir. Buna kar\u015f\u0131l\u0131k, undervoltage release cihaz\u0131 olarak adland\u0131r\u0131lan bir g\u00fcvenlik mekanizmas\u0131, bobini enerjilendi\u011finde mekanizmay\u0131 kapal\u0131 tutan bir mandall\u0131 solenoid olarak eklenmelidir. IEC\/EN 60947-2\u2019ye g\u00f6re bu t\u00fcr cihazlar\u0131n t\u00fcm b\u00fcy\u00fck \u00fcreticiler i\u00e7in spesifikasyonlar\u0131 ayn\u0131d\u0131r:<\/p>\n<table>\n<tbody>\n<tr>\n<th>Kontrol voltaj\u0131 (nominal bobin voltaj\u0131n\u0131n bir kesri olarak)<\/th>\n<th>Cihaz davran\u0131\u015f\u0131<\/th>\n<\/tr>\n<tr>\n<td>0,35 \u00d7 U\u2019nun alt\u0131nda<sub>n<\/sub><\/td>\n<td>Kesin a\u00e7ma \u2014 solenoid serbest b\u0131rak\u0131r ve cihaz a\u00e7\u0131l\u0131r<\/td>\n<\/tr>\n<tr>\n<td>0,35 ile 0,70 \u00d7 U aras\u0131nda<sub>n<\/sub><\/td>\n<td>Belirsiz \u2014 a\u00e7abilir veya a\u00e7mayabilir; bu bant kas\u0131tl\u0131 olarak bir spesifikasyon noktas\u0131 de\u011fildir<\/td>\n<\/tr>\n<tr>\n<td>0,70 \u00d7 U\u2019nun \u00fczerinde<sub>n<\/sub><\/td>\n<td>Undervoltage fonksiyonundan a\u00e7ma olmaz<\/td>\n<\/tr>\n<tr>\n<td>Yakla\u015f\u0131k 0,85 \u00d7 U\u2019ya geri d\u00f6n\u00fc\u015f<sub>n<\/sub><\/td>\n<td>Kapanmaya tekrar izin verilir \u2014 ancak sadece kas\u0131tl\u0131 i\u015flemle, asla otomatik olarak<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Bu tablodan iki \u00e7ok pratik \u00e7\u0131kar\u0131m yap\u0131labilir. Birincisi, belirsiz 35-70% band\u0131n\u0131n, bir UVR'nin herhangi bir voltaj seviyesinde a\u00e7ma yapaca\u011f\u0131na g\u00fcvenilemeyece\u011fi anlam\u0131na gelmesidir; bu, sadece bir hata emniyet cihaz\u0131d\u0131r, hassas bir izleme cihaz\u0131 de\u011fil. \u0130kinci madde ise, voltaj d\u00fc\u015f\u00fc\u015fleri hakk\u0131nda k\u0131sa yaz\u0131l\u0131 \u015fikayetlerin oldu\u011fu kurulumlarda bir zaman gecikmeli birim mevcut olmas\u0131d\u0131r; bu birim, voltaj d\u00fc\u015f\u00fc\u015flerinin yakla\u015f\u0131k 200 milisaniyeden k\u0131sa s\u00fcrmesi durumunda a\u00e7may\u0131 geciktirmeye izin verir, b\u00f6ylece s\u00fcreci etkilemeyen k\u0131sa bir voltaj d\u00fc\u015f\u00fc\u015f\u00fc tesisin kapanmas\u0131n\u0131 engeller. Voltaj d\u00fc\u015f\u00fc\u015flerinin yayg\u0131n oldu\u011fu durumlarda zaman gecikmeli UVR se\u00e7imi, faydal\u0131 koruma sa\u011flamak ile operat\u00f6rlerin kullanmayaca\u011f\u0131 bir \u015fey sa\u011flamak aras\u0131ndaki farkt\u0131r.<\/p>\n<h2>\u0130ki Form: Kontakt\u00f6r vs Kesici<\/h2>\n<p>Hangi form t\u00fcr\u00fcn\u00fc kulland\u0131\u011f\u0131n\u0131z\u0131 anlayabilmek, iki terimin farkl\u0131 olmas\u0131 ve sistem i\u00e7inde ayn\u0131 amaca hizmet etmemesi nedeniyle \u00e7o\u011fu spesifikasyon hatas\u0131n\u0131 \u00f6nleyecektir.<\/p>\n<table>\n<tbody>\n<tr>\n<th><\/th>\n<th>Kontakt\u00f6r tabanl\u0131 ba\u015flat\u0131c\u0131<\/th>\n<th>Devre kesici<\/th>\n<\/tr>\n<tr>\n<td>Tutma mekanizmas\u0131<\/td>\n<td>Elektriksel olarak tutulan bobin art\u0131 yard\u0131mc\u0131 tutma konta\u011f\u0131<\/td>\n<td>Mekanik mandal<\/td>\n<\/tr>\n<tr>\n<td>Besleme kayb\u0131nda ne olur<\/td>\n<td>Bobin enerjisi kesilir, ana kontaklar otomatik olarak a\u00e7\u0131l\u0131r<\/td>\n<td>Kapal\u0131 kal\u0131r \u2014 mandal besleme kayb\u0131ndan etkilenmez<\/td>\n<\/tr>\n<tr>\n<td>No-volt a\u00e7ma sa\u011flan\u0131r<\/td>\n<td>Bobinin kendisi taraf\u0131ndan, ekstra maliyetsiz<\/td>\n<td>Bobin yuvas\u0131nda ayr\u0131 bir d\u00fc\u015f\u00fck voltaj a\u00e7ma aksesuar\u0131<\/td>\n<\/tr>\n<tr>\n<td>Kesinti sonras\u0131 yeniden ba\u015flatma<\/td>\n<td>Tekrar ba\u015flat d\u00fc\u011fmesine bas\u0131lmadan imkans\u0131z<\/td>\n<td>Sadece UVR tak\u0131l\u0131ysa imkans\u0131z; tak\u0131l\u0131 de\u011filse kesici basit\u00e7e kapal\u0131 kal\u0131r<\/td>\n<\/tr>\n<tr>\n<td>Tipik Kullan\u0131m<\/td>\n<td>Motor ba\u015flat\u0131c\u0131lar\u0131: DOL, y\u0131ld\u0131z-\u00fc\u00e7gen, yumu\u015fak ba\u015flat\u0131c\u0131, VFD kontakt\u00f6r<\/td>\n<td>Makine ay\u0131r\u0131c\u0131lar\u0131, motor devre kesicileri, ATS giri\u015f kesicileri, besleyici koruma<\/td>\n<\/tr>\n<tr>\n<td>Ge\u00e7erli standart<\/td>\n<td>IEC\/EN 60947-4-1<\/td>\n<td>IEC\/EN 60947-2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Kontakt\u00f6r \u00f6rne\u011fi, \u201cno-volt release\u201d teriminin \u0130ngiliz ve Milletler Toplulu\u011fu standartlar\u0131nda neden bu kadar yayg\u0131n oldu\u011funu a\u00e7\u0131klar; \u00e7\u00fcnk\u00fc her DOL ba\u015flat\u0131c\u0131, bu spesifikasyon yap\u0131lm\u0131\u015f olsun ya da olmas\u0131n b\u00f6yle bir mekanizma ile gelir, bu da bize TONVR (termal a\u015f\u0131r\u0131 y\u00fck, no-volt a\u00e7ma) k\u0131saltmas\u0131n\u0131 ba\u015flat\u0131c\u0131n\u0131n standart korumas\u0131 olarak verir. Kesici \u00f6rne\u011fi ise ayn\u0131 spesifikasyonun neden maliyetli olabilece\u011fini a\u00e7\u0131klar; \u00e7\u00fcnk\u00fc ekipman\u0131 korumak i\u00e7in kullan\u0131lan yukar\u0131 ak\u0131\u015f cihaz\u0131 kontakt\u00f6r yerine kal\u0131pl\u0131 devre kesici ise, hata emniyet fonksiyonu ayr\u0131 bir aksesuar olarak sat\u0131n al\u0131nmal\u0131d\u0131r. Bu \u00f6rneklerden \u00e7\u0131kar\u0131labilecek temel kurallar \u015funlard\u0131r; ay\u0131rma cihaz\u0131 kontakt\u00f6r ise fonksiyon \u00fccretsizdir, kesici ise kullan\u0131c\u0131 UVR par\u00e7as\u0131na \u00f6zel olarak eri\u015fim talep etmeli ve bobin i\u00e7in \u00e7er\u00e7evede uygun bir yuva olup olmad\u0131\u011f\u0131n\u0131 do\u011frulamal\u0131d\u0131r.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4239\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/09\/UVR-vs-Shunt-Trip.webp\" alt=\"UVR vs \u015e\u00f6nt A\u00e7ma\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>UVR vs \u015e\u00f6nt A\u00e7ma<\/h2>\n<p>Benzer g\u00f6r\u00fcnmelerine ve ayn\u0131 konuma monte edilmelerine ra\u011fmen, \u015f\u00f6nt a\u00e7ma yard\u0131mc\u0131 ve d\u00fc\u015f\u00fck voltaj a\u00e7ma yard\u0131mc\u0131lar\u0131 sat\u0131n alma sipari\u015flerinde s\u0131k\u00e7a kar\u0131\u015ft\u0131r\u0131l\u0131r \u00e7\u00fcnk\u00fc tamamen farkl\u0131 i\u015flevlere hizmet ederler. \u0130ki aksesuar\u0131n kar\u0131\u015ft\u0131r\u0131lmas\u0131 tehlikelidir \u00e7\u00fcnk\u00fc \u015f\u00f6nt a\u00e7ma, k\u0131r\u0131k bir kontrol kablosu durumunda hi\u00e7bir koruyucu mekanizma sa\u011flamaz.<\/p>\n<table>\n<tbody>\n<tr>\n<th><\/th>\n<th>D\u00fc\u015f\u00fck gerilim a\u00e7ma (no-volt, UVR, MN-tipi)<\/th>\n<th>\u015e\u00f6nt tripi (SHT, MX-tipi)<\/th>\n<\/tr>\n<tr>\n<td>Tetikleme<\/td>\n<td>Bobin voltaj kayb\u0131, 0.35 \u00d7 U'nun alt\u0131nda<sub>n<\/sub><\/td>\n<td>7 \u00d7 U'nun \u00fczerinde voltaj uygulanmas\u0131<sub>n<\/sub>, en az 20 ms'lik bir darbe olarak<\/td>\n<\/tr>\n<tr>\n<td>Kontrol kablosu kesilirse davran\u0131\u015f<\/td>\n<td>Cihaz a\u00e7\u0131l\u0131r \u2014 varsay\u0131lan olarak g\u00fcvenli<\/td>\n<td>Hi\u00e7bir \u015fey olmaz \u2014 a\u00e7ma komutu asla ula\u015fmaz<\/td>\n<\/tr>\n<tr>\n<td>G\u00fc\u00e7 kesintisinde davran\u0131\u015f<\/td>\n<td>Cihaz a\u00e7\u0131l\u0131r<\/td>\n<td>Cihaz kapal\u0131 kal\u0131r<\/td>\n<\/tr>\n<tr>\n<td>Yeniden kapama<\/td>\n<td>Yakla\u015f\u0131k 0.85 \u00d7 U'nun \u00fczerinde izin verilir<sub>n<\/sub>, ve sadece kas\u0131tl\u0131 bir i\u015flemle<\/td>\n<td>Komut verildi\u011finde her zaman izin verilir<\/td>\n<\/tr>\n<tr>\n<td>Bobin s\u00fcrekli enerjilenmeli mi?<\/td>\n<td>Evet \u2014 cihaz\u0131 kapal\u0131 tutma \u015fekli budur<\/td>\n<td>Hay\u0131r \u2014 darbe \u015feklindedir<\/td>\n<\/tr>\n<tr>\n<td>Tipik uygulamalar<\/td>\n<td>Acil durdurma devreleri, g\u00f6zetimsiz yeniden ba\u015flatma \u00f6nleme, makine g\u00fcvenli\u011fi, kaynak sa\u011fl\u0131kl\u0131 izin verme transfer \u015femalar\u0131nda<\/td>\n<td>Koruma r\u00f6lesinden uzaktan a\u00e7ma, yang\u0131n alarm kilidi, y\u00fck azaltma, BMS kaynakl\u0131 kesme<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u0130ki aksesuar aras\u0131ndaki fark\u0131 hat\u0131rlaman\u0131n kolay yolu, \u015f\u00f6nt tripinin bir komut gerektirmesi, d\u00fc\u015f\u00fck gerilim a\u00e7man\u0131n ise g\u00fcvence gerektirmesidir. Ba\u015fka bir deyi\u015fle, \u015f\u00f6nt trip a\u00e7ma komutunu bekler, ancak d\u00fc\u015f\u00fck gerilim a\u00e7ma cihaz\u0131 kapal\u0131 tutar ve g\u00fc\u00e7 kesildi\u011finde hemen a\u00e7\u0131l\u0131r. Daha \u00f6nce belirtildi\u011fi gibi, her ikisi de panelin dahili termal-manyetik veya elektronik a\u00e7ma cihaz\u0131n\u0131 atlayan harici bir a\u00e7ma mekanizmas\u0131 sa\u011flar; ancak sadece biri g\u00fcvenli \u015fekilde ar\u0131zalan\u0131r. Ama\u00e7 personel g\u00fcvenli\u011fi oldu\u011funda, bu fark t\u00fcm noktad\u0131r ve bir kesicinin a\u015f\u0131r\u0131 ak\u0131m a\u00e7mas\u0131n\u0131n bir\u00e7ok ko\u015ful taraf\u0131ndan tetiklenebilece\u011fi, bu konunun rehberimizde ayr\u0131 olarak ele al\u0131nd\u0131\u011f\u0131 not edilmelidir. <a href=\"https:\/\/huyuglobal.com\/tr\/blog\/what-causes-a-circuit-breaker-to-trip\/\">devre kesicinin neden devreyi kesti\u011fi<\/a>.<\/p>\n<h2>Kullan\u0131m Alanlar\u0131<\/h2>\n<p>Uygulamalar, g\u00fcvenlik gerektirenler ve s\u00fcre\u00e7 odakl\u0131 olanlar olarak ayr\u0131l\u0131r; bu nedenle g\u00fcvenlik gereksinimlerini kullanan ekipman etkili \u015fekilde devreye girer.<\/p>\n<ul>\n<li>Motor ba\u015flat\u0131c\u0131lar. DOL veya y\u0131ld\u0131z-\u00fc\u00e7gen tipi, yumu\u015fak kalk\u0131\u015f ve VFD tipi motor ba\u015flat\u0131c\u0131lar, kontrol devresi voltaj\u0131yla tutulan kontakt\u00f6rler kullan\u0131r. No-volt \u00f6zelli\u011fi, istenmeyen yeniden ba\u015flatmalara kar\u015f\u0131 say\u0131s\u0131z cihaz\u0131 korur.<\/li>\n<li>Makine tak\u0131mlar\u0131 ve ah\u015fap i\u015fleme ekipmanlar\u0131. Testereler, frezeler, presler ve matkap presleri, cihaz\u0131n gereklili\u011finin m\u00fckemmel bir \u00f6rne\u011fini sunar; cihaz, makine operat\u00f6r\u00fc kesici tak\u0131m\u0131 de\u011fi\u015ftirirken veya tala\u015flar\u0131 temizlerken istenmeyen yeniden ba\u015flatmay\u0131 \u00f6nlemek i\u00e7in tasarlanm\u0131\u015ft\u0131r. Makine g\u00fcvenli\u011fi y\u00f6netmelikleri ayr\u0131ca istenmeyen ba\u015flatmalar\u0131 \u00f6nlemek i\u00e7in g\u00fcvenlik \u00f6nlemleri belirtir.<\/li>\n<li>Acil durdurma devreleri. E-stop bobin devresinde kesme olarak ba\u011fland\u0131\u011f\u0131nda, PLC giri\u015fi olarak ba\u011flanmas\u0131na k\u0131yasla g\u00fcvenli cihaz olur. PLC giri\u015fi yanl\u0131\u015f okunabilir, g\u00fc\u00e7 kayb\u0131 ya\u015fayabilir veya ar\u0131zal\u0131 mod\u00fclde kalabilir; kontrol devresindeki seri kontak ise kalmaz.<\/li>\n<li>Vin\u00e7ler, asans\u00f6rler ve kald\u0131rma ekipmanlar\u0131. G\u00fc\u00e7 kayb\u0131, kontrols\u00fcz yeniden ba\u015flatma ve y\u00fck\u00fcn kontrols\u00fcz d\u00fc\u015f\u00fc\u015f\u00fcn\u00fc \u00f6nleyebilir.<\/li>\n<li>G\u00f6zetimsiz pompalama ve uzaktan i\u015flemler. Kuyu pompalar\u0131, sulama pompa istasyonlar\u0131 ve uzaktan takviye pompa istasyonlar\u0131 sahada operat\u00f6r olmadan \u00e7al\u0131\u015f\u0131r. Operat\u00f6r\u00fcn istemedi\u011fi son \u015fey, g\u00fc\u00e7 geri geldi\u011finde kuru hatta veya t\u0131kanm\u0131\u015f boru hatt\u0131nda pompan\u0131n yeniden \u00e7al\u0131\u015fmaya ba\u015flamas\u0131d\u0131r.<\/li>\n<li>Jenerat\u00f6r ve otomatik transfer i\u015flemleri. Alt voltaj r\u00f6lesi, gelen besleme gerilimi ger\u00e7ekten sa\u011flanana kadar izin verici blok kapan\u0131\u015f\u0131 olarak hareket edecektir.<\/li>\n<li>Kilitlemeli yang\u0131n alarm\u0131 ve bina y\u00f6netim sistemleri. Yang\u0131n durumunda, yang\u0131n kontrol paneli kontrol gerilimi devresini keser.<\/li>\n<li>Y\u00fck atma. Bir kamu hizmeti veya saha kontrol\u00f6r\u00fc, bir besleme ko\u015fulunda bir devrenin a\u00e7\u0131lmas\u0131n\u0131 gerekti\u011finde, kontrol gerilimi yolu kablolu bir se\u00e7enek sa\u011flar.<\/li>\n<\/ul>\n<p>Da\u011f\u0131t\u0131m ekipman\u0131nda, alt voltaj serbest b\u0131rakman\u0131n, yard\u0131mc\u0131 ve alarm kontaklar\u0131, \u015f\u00f6nt tripler, motor operat\u00f6rleri ve d\u00f6ner manuel operat\u00f6rlerle birlikte ayn\u0131 yuvalar\u0131 i\u015fgal eden bir\u00e7ok se\u00e7enekten biri oldu\u011fu \u00f6nemlidir. UVR'li devre kesici i\u00e7in bir spesifikasyon, sipari\u015f vermeden \u00f6nce aksesuar y\u0131\u011f\u0131n\u0131n\u0131n do\u011frulanmas\u0131n\u0131 sa\u011flamal\u0131d\u0131r ve kararla\u015ft\u0131r\u0131lmal\u0131d\u0131r: tak\u0131lan koruman\u0131n kal\u0131planm\u0131\u015f kasa kesici mi yoksa minyat\u00fcr cihaz m\u0131 oldu\u011fu, hangi aksesuarlar\u0131n var oldu\u011funu etkileyen bir karard\u0131r, bu da rehberimizde ele al\u0131nm\u0131\u015ft\u0131r. <a href=\"https:\/\/huyuglobal.com\/tr\/blog\/what-is-mccb-and-mcb\/\">MCCB ve MCB aras\u0131ndaki fark<\/a>.<\/p>\n<h2>Alternatifler ve Yedekler<\/h2>\n<p>Hata g\u00fcvenli i\u015flev ger\u00e7ek anlamda de\u011fi\u015ftirilemez, ancak her biri kendi riski olan \u00e7e\u015fitli yan \u00fcr\u00fcnlerle taklit edilebilir.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Yakla\u015f\u0131m<\/th>\n<th>Ba\u015fard\u0131\u011f\u0131 \u015fey<\/th>\n<th>Takas<\/th>\n<\/tr>\n<tr>\n<td>Kontakt\u00f6r tutma devresi (ba\u015flatma d\u00fc\u011fmesi \u00fczerinde yard\u0131mc\u0131 NO kontak)<\/td>\n<td>Klasik no-volt serbest b\u0131rakma \u2014 yeniden ba\u015flatma kas\u0131tl\u0131 eylem gerektirir<\/td>\n<td>Yaln\u0131zca y\u00fck bir kontakt\u00f6r taraf\u0131ndan anahtarlan\u0131yorsa ge\u00e7erlidir, bir kesici taraf\u0131ndan de\u011fil<\/td>\n<\/tr>\n<tr>\n<td>Bir kesicide alt voltaj serbest b\u0131rakma aksesuar\u0131<\/td>\n<td>Mekanik mandall\u0131 cihazlarda ayn\u0131 hata g\u00fcvenli davran\u0131\u015f<\/td>\n<td>Ek maliyet, bir bobin yuvas\u0131 t\u00fcketir, s\u00fcrekli enerjili bir kontrol beslemesi gerektirir<\/td>\n<\/tr>\n<tr>\n<td>\u015e\u00f6nt trip art\u0131 r\u00f6le veya PLC mant\u0131\u011f\u0131<\/td>\n<td>Programlama ile yeniden ba\u015flatma engellemesini taklit edebilir<\/td>\n<td>G\u00fcvenli olmayan ar\u0131za: mant\u0131k veya beslemesi kesilirse, kesici kapal\u0131 kal\u0131r. G\u00fcvenlik fonksiyonu olarak kabul edilemez<\/td>\n<\/tr>\n<tr>\n<td>Yeniden ba\u015flatma engellemeli motor koruma r\u00f6lesi<\/td>\n<td>Bir trip veya besleme kayb\u0131ndan sonra elektronik yeniden ba\u015flatma engellemesi, genellikle ayarlanabilir gecikme ile<\/td>\n<td>R\u00f6lenin enerjili ve do\u011fru yap\u0131land\u0131r\u0131lm\u0131\u015f olmas\u0131na ba\u011fl\u0131d\u0131r; kablolu bir garanti de\u011fildir<\/td>\n<\/tr>\n<tr>\n<td>Undervoltaj izleme ile yumu\u015fak yol verici veya VFD<\/td>\n<td>Engellenmi\u015f yeniden ba\u015flatma dahil yap\u0131land\u0131r\u0131labilir yeniden ba\u015flatma davran\u0131\u015f\u0131<\/td>\n<td>Elektroni\u011fe ayn\u0131 ba\u011f\u0131ml\u0131l\u0131k; ayr\u0131ca devreye alma i\u00e7in bir de\u011fi\u015fken ekler<\/td>\n<\/tr>\n<tr>\n<td>Mekanik olarak kilitlenen kontakt\u00f6r<\/td>\n<td>Besleme kesintisi s\u0131ras\u0131nda son durumunu korur<\/td>\n<td>Z\u0131t davran\u0131\u015f \u2014 beklenmedik \u015fekilde yeniden ba\u015flatabilir. Otomatik yeniden ba\u015flatman\u0131n istendi\u011fi durumlarda kas\u0131tl\u0131 olarak kullan\u0131l\u0131r, asla bir g\u00fcvenlik cihaz\u0131 olarak de\u011fil<\/td>\n<\/tr>\n<tr>\n<td>Kilitlenebilir yerel izolat\u00f6r<\/td>\n<td>Bak\u0131m s\u0131ras\u0131nda personel korumas\u0131<\/td>\n<td>G\u00f6zetimsiz kesinti s\u0131ras\u0131nda operat\u00f6r\u00fc de\u011fil, bak\u0131m personelini korur<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Tablo i\u00e7eri\u011finde alt\u0131 \u00e7izilmesi gereken bir desen vard\u0131r: fiziksel \u00e7\u00f6z\u00fcmler sistemin g\u00fcvenilirli\u011fini garanti ederken, elektrik sistemleri bunu yapmaz. Ger\u00e7ekten de, Kontrol Voltaj\u0131 kayb\u0131 yanl\u0131\u015f yorumlanamazken, bir PLC giri\u015fi yanl\u0131\u015f okunabilir. Bu nedenle, hata g\u00fcvenli prensip, insan hayat\u0131n\u0131 koruyan her \u015fey i\u00e7in her zaman bir sert kablo se\u00e7ene\u011fi olmas\u0131 gerekti\u011fini, di\u011fer t\u00fcm operasyonel \u00f6zelliklerin ise elektronik olarak ger\u00e7ekle\u015ftirilebilece\u011fini \u00f6nerir.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4240\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/09\/Do-You-Need-UVR.webp\" alt=\"\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>Birine \u0130htiyac\u0131n\u0131z Var m\u0131?<\/h2>\n<p>A\u00e7\u0131k\u00e7as\u0131, kontakt\u00f6rle kontrol edilen herhangi bir motorda bir tane olma ihtimali y\u00fcksektir. As\u0131l sorun, kontakt\u00f6rle kontrol edilmeyen di\u011fer cihazlar\u0131n buna ihtiyac\u0131 olup olmad\u0131\u011f\u0131d\u0131r. K\u0131sa bir kontrol listesi yapmak faydal\u0131 olacakt\u0131r.<\/p>\n<p>A\u015fa\u011f\u0131dakilerden herhangi biri do\u011fruysa bir tane gerekecektir: beklenmedik bir yeniden ba\u015flatmadan kaynaklanan \u015fok olas\u0131l\u0131\u011f\u0131; y\u00fck bir motor ise ve s\u00fcrekli undervoltaj nedeniyle hasar riski varsa; kontrol kablosu kesilirse sistemin g\u00fcvenli \u015fekilde kapanmas\u0131 gerekiyorsa; uygulama g\u00f6zetimsiz \u00e7al\u0131\u015ft\u0131r\u0131l\u0131yorsa; belirli ko\u015fullarda y\u00fck\u00fcn kesilmesi gerekiyorsa (yang\u0131n veya gaz); veya transfer \u015femas\u0131 kayna\u011f\u0131n sa\u011fl\u0131kl\u0131 oldu\u011funu do\u011frulamadan kapama yapmamal\u0131d\u0131r.<\/p>\n<p>\u0130lgili ekipman g\u00f6zetim alt\u0131nda ve yerel manuel kontrol alt\u0131ndaysa; y\u00fck diren\u00e7li bir devreyse veya devre ile ilgili herhangi bir g\u00fcvenlik tehlikesi yoksa; veya sistemin kapanma sonras\u0131 yeniden ba\u015flat\u0131lmas\u0131yla ilgili bir rahats\u0131zl\u0131k kabul edilebilir ve tasar\u0131mda kilitleme mekanizmas\u0131 kullan\u0131l\u0131yorsa, bir tane gerekmeyebilir. Bu son durumda, kilitlemelerin gereklili\u011fi koruma cihaz\u0131n\u0131n varsay\u0131lan davran\u0131\u015f\u0131na b\u0131rak\u0131lmak yerine tasar\u0131m karar\u0131nda ele al\u0131nmal\u0131d\u0131r.<\/p>\n<h2>Belirleme ve Test Etme<\/h2>\n<p>D\u00f6rt belirleme noktas\u0131 cihaz\u0131n d\u00fczg\u00fcn \u00e7al\u0131\u015f\u0131p \u00e7al\u0131\u015fmad\u0131\u011f\u0131n\u0131 do\u011frular.<\/p>\n<ul>\n<li>Bobini hat g\u00fcc\u00fcne de\u011fil, kontrol g\u00fcc\u00fcne ba\u011flay\u0131n. Bu, sahada en s\u0131k yap\u0131lan hata olup, en yan\u0131lt\u0131c\u0131 belirtiye yol a\u00e7ar \u2013 \u201c\u00e7al\u0131\u015fmayan\u201d yepyeni bir d\u00fc\u015f\u00fck voltaj tripi. Bobinin voltaj derecesi, kesicinin g\u00fc\u00e7 kutuplar\u0131n\u0131n voltaj derecesiyle ayn\u0131 de\u011fildir, ancak panel taraf\u0131ndan \u00fcretilen kontrol voltaj\u0131n\u0131n voltaj derecesi, \u00f6rne\u011fin 24 \u2013 30 V DC, 110 \u2013 130 V AC\/DC veya 220 \u2013 240 V AC\/DC\u2019dir. Mekanik sorunlar hakk\u0131nda erken varsay\u0131mlardan ka\u00e7\u0131nmak i\u00e7in kontrol devresi \u015femas\u0131ndaki bobin voltaj derecesini kontrol edin ve \u201c\u00e7al\u0131\u015fm\u0131yor\u201d diye iade edilen bir\u00e7ok aksesuar\u0131n asl\u0131nda yanl\u0131\u015f bobine sahip oldu\u011funu anlay\u0131n.<\/li>\n<li>Zaman gecikmeli versiyonu dikkatle se\u00e7in. Kontrol edilen s\u00fcrecin devam etti\u011fi 200 ms\u2019den k\u0131sa voltaj d\u00fc\u015f\u00fc\u015fleri ya\u015fayan uygulamalarda, zaman gecikmeli versiyon gereksiz a\u00e7ma yapma olas\u0131l\u0131\u011f\u0131 y\u00fcksektir. Bu uygulamalar i\u00e7in anl\u0131k versiyon daha iyi koruma sa\u011flar.<\/li>\n<li>Kapanman\u0131n engellendi\u011fini do\u011frulay\u0131n. Aksesuar\u0131n amac\u0131 sadece a\u00e7ma yapmak de\u011fil, voltaj nominal de\u011ferinin \u2019ine veya daha fazlas\u0131na geri d\u00f6nene kadar devrenin kapanmas\u0131n\u0131 reddetmektir. Do\u011frulama, varsay\u0131mlara dayanmak yerine devreye alma s\u0131ras\u0131nda yap\u0131lmal\u0131d\u0131r.<\/li>\n<li>Bobini periyodik test program\u0131na al\u0131n. \u00dcreticiler, a\u00e7ma bobinlerinin rutin test edilmesini \u00f6nerir \u2013 genellikle en az alt\u0131 ayda bir \u2013 \u00e7\u00fcnk\u00fc ar\u0131zal\u0131 bir bobin, ihtiya\u00e7 duyulana kadar \u00e7al\u0131\u015fan bir bobinden ay\u0131rt edilemez. Elektriksel b\u00fct\u00fcnl\u00fck i\u00e7in \u015f\u00fcpheli bir cihaz\u0131n testi, herhangi bir di\u011fer kesici ar\u0131zas\u0131n\u0131n te\u015fhisi i\u00e7in kullan\u0131lan ayn\u0131 teknikleri kullan\u0131r; bu konuda rehberimiz <a href=\"https:\/\/huyuglobal.com\/tr\/blog\/how-to-tell-if-a-breaker-is-bad\/\">bir devre kesicinin bozuk olup olmad\u0131\u011f\u0131n\u0131 nas\u0131l anlayaca\u011f\u0131n\u0131z<\/a> detayl\u0131 bilgi verir.<\/li>\n<\/ul>\n<p>Bile\u015fenlerin panel i\u00e7in se\u00e7ildi\u011fi durumlarda, koruma katman\u0131 kesici, ilgili aksesuarlar ve ayn\u0131 DIN ray\u0131na monte edilmi\u015f sertifikal\u0131 mini cihazlar\u0131 i\u00e7eren bir paket olarak belirtilmelidir. HUM18-63N serisi, bu rol\u00fc dolduran cihaz t\u00fcr\u00fcne bir \u00f6rnektir \u2014 1P\u2019den 4P\u2019ye kadar 63 A\u2019de B, C ve D e\u011frileri ile sertifikal\u0131 mini devre kesici hatt\u0131 \u2014 ve <a href=\"https:\/\/huyuglobal.com\/tr\/product\/hum18-63n-mcb-1p-to-4p-63a-type-b-c-d\/\">HUM18-63N MCB \u00fcr\u00fcn sayfas\u0131<\/a> al\u0131c\u0131lar\u0131n belgelenmi\u015f olarak g\u00f6rmeyi beklemesi gereken spesifikasyon format\u0131n\u0131 g\u00f6sterir.<\/p>\n<h2>Yayg\u0131n Hatalar<\/h2>\n<ul>\n<li>Voltajsuz a\u00e7ma ile kullan\u0131lmak \u00fczere \u015f\u00f6nt trip sipari\u015f etmek \u2014 her iki par\u00e7a numaras\u0131 benzer g\u00f6r\u00fcn\u00fcr ve ayn\u0131 terminal yuvalar\u0131na uyar, ancak bir y\u00f6ntem ar\u0131zaya kar\u015f\u0131 g\u00fcvenlidir, di\u011feri de\u011fildir.<\/li>\n<li>Bobini hat voltaj\u0131na ba\u011flamak. Bu, ya yanm\u0131\u015f bir bobin ya da a\u00e7\u0131k kalan bir ekipman garantiler.<\/li>\n<li>Mekanik mandall\u0131 bir kontakt\u00f6r\u00fc ar\u0131zaya kar\u015f\u0131 g\u00fcvenli olarak kabul etmek. Bu tasar\u0131m asl\u0131nda durumunu korur, ki bu olmas\u0131 gerekenin tam tersidir.<\/li>\n<li>Acil durdurma fonksiyonunu sadece PLC\u2019de yaz\u0131l\u0131m fonksiyonu yapmak (sert kablolama olmadan). Yaz\u0131l\u0131m e-stop ar\u0131zaya kar\u015f\u0131 g\u00fcvenli bir e-stop de\u011fildir; e-stop etkisini garanti eden kontrol devresindeki sert kablo kesintisidir.<\/li>\n<li>Voltaj dalgalanmalar\u0131na yatk\u0131n bir i\u015f sahas\u0131nda zaman gecikmeli \u00f6zelli\u011fin uygulanmamas\u0131. Sonu\u00e7 olarak, operasyonunuz gereksiz kapanmalar ya\u015fayacakt\u0131r; gereksiz kapanmalar meydana geldi\u011finde, yedek koruma kald\u0131r\u0131lm\u0131\u015f olur.<\/li>\n<li>Aksesuar y\u0131\u011f\u0131n\u0131 dahil etmeyi unutmak. Bir bobin yuvas\u0131 olan bir \u00e7er\u00e7eve hem UVR hem de \u015f\u00f6nt trip bar\u0131nd\u0131ramaz.<\/li>\n<li>Bobinin kendisi \u00fczerinde asla test yapmamak. Ar\u0131za, kritik hale gelene kadar g\u00f6r\u00fcn\u00fcr de\u011fildir.<\/li>\n<\/ul>\n<h2>SSS<\/h2>\n<h3>No-volt bobininin ana i\u015flevi nedir?<\/h3>\n<p>No-volt bobininin amac\u0131, kontrol voltaj\u0131 sa\u011fland\u0131\u011f\u0131 s\u00fcrece kontrol cihaz\u0131na enerji sa\u011flamakt\u0131r. Kontrol voltaj\u0131 kayb\u0131 oldu\u011funda, bobin devreyi a\u00e7arak elektrik geri geldi\u011finde ekipman\u0131n otomatik olarak s\u0131f\u0131rlanmas\u0131n\u0131 \u00f6nler. Bobin, kontakt\u00f6r starterda kontakt\u00f6r\u00fc tutan kontrol voltaj\u0131n\u0131 sa\u011flayarak bunu do\u011frudan yapar, ancak di\u011fer durumlarda mekanik kilitleme mekanizmas\u0131n\u0131 tutmak i\u00e7in ayr\u0131 bir d\u00fc\u015f\u00fck voltaj a\u00e7ma aksesuar\u0131 sa\u011flan\u0131r. Ayr\u0131ca, a\u015f\u0131r\u0131 \u0131s\u0131nma ve motor hasar\u0131na yol a\u00e7abilecek s\u00fcrekli d\u00fc\u015f\u00fck voltaj i\u00e7in koruma sa\u011flar.<\/p>\n<h3>NC ve NO kontaklar aras\u0131ndaki fark nedir?<\/h3>\n<p>Normalde a\u00e7\u0131k (NO) kontak, dinlenme halinde a\u00e7\u0131k olup etkinle\u015ftirildi\u011finde kapan\u0131r; normalde kapal\u0131 (NC) kontak ise dinlenme halinde kapal\u0131 olup etkinle\u015ftirildi\u011finde a\u00e7\u0131l\u0131r. Devre, kontaklar\u0131n iki a\u015famal\u0131 \u00e7al\u0131\u015fmas\u0131n\u0131 olu\u015fturur: ba\u015flatma butonu ve tutma kontaklar\u0131 NO\u2019dur, b\u00f6ylece butona bas\u0131ld\u0131\u011f\u0131nda devre kurulur; durdurma butonu, acil durdurma ve a\u015f\u0131r\u0131 y\u00fck r\u00f6lesi kontaklar\u0131 ise NC\u2019dur, b\u00f6ylece kapal\u0131 kald\u0131klar\u0131 s\u00fcrece normal \u00e7al\u0131\u015fma sa\u011flan\u0131r. NC kontaklar, ekipman ar\u0131zas\u0131 durumunda \u201cizin verici\u201d bir i\u015flem yerine \u201ckapal\u0131\u201d durumu olu\u015fturduklar\u0131 i\u00e7in g\u00fcvenlik devrelerinde kullan\u0131l\u0131r.<\/p>\n<h3>No-volt kontak nedir?<\/h3>\n<p>Bir kontakt\u00f6r starterda, no-volt kontak, ba\u015flatma butonuyla paralel olan yard\u0131mc\u0131 normalde a\u00e7\u0131k kontak olup tutma konta\u011f\u0131 olarak da bilinir. Ba\u015flatma butonuna bas\u0131ld\u0131\u011f\u0131nda bobin enerjilenir ve ana kontaklar kapan\u0131r. Yard\u0131mc\u0131 kontak da kapan\u0131r ve bobin ak\u0131m\u0131 i\u00e7in bir yol sa\u011flar. Bu \u00f6zellik devrenin kendi kendini s\u00fcrd\u00fcrmesini sa\u011flar. No-volt a\u00e7ma, bobin ak\u0131m\u0131n\u0131n kontak \u00fczerinden kontrol g\u00fcc\u00fcne ba\u011fl\u0131 olmas\u0131 nedeniyle \u00e7al\u0131\u015f\u0131r. Kontrol g\u00fcc\u00fcnde herhangi bir kay\u0131p olursa, bobin enerjisini kaybeder. Tutma konta\u011f\u0131 ar\u0131zal\u0131ysa, motor sadece butona bas\u0131ld\u0131\u011f\u0131nda \u00e7al\u0131\u015ft\u0131r\u0131labilir.<\/p>\n<h3>Bir DOL starter zaten no-volt a\u00e7ma i\u00e7erir mi?<\/h3>\n<p>Evet, elektromanyetik olarak tutulan kontakt\u00f6rl\u00fc t\u00fcm do\u011frudan hat \u00fczeri starterlar no-volt a\u00e7ma i\u00e7erir. No-volt a\u00e7ma ile termal a\u015f\u0131r\u0131 y\u00fck korumas\u0131 i\u00e7in kullan\u0131lan k\u0131saltma TONVR\u2019dir. Ek bir yard\u0131mc\u0131 sat\u0131n almaya gerek yoktur. Mekanik kilitli bir devre kesici durumunda cihaz ekstra bir kalem haline gelir.<\/p>\n<h3>D\u00fc\u015f\u00fck voltaj a\u00e7mam neden belli bir sebep olmadan at\u0131yor?<\/h3>\n<p>Bu durumda genellikle meydana gelen birka\u00e7 kesinti nedeni vard\u0131r. Ba\u015fka ekipmanlar \u00e7al\u0131\u015fmaya ba\u015flad\u0131\u011f\u0131nda bir kesinti olursa, kurulum zaman gecikmeli bir serbest b\u0131rakma ile g\u00fcncellenmelidir. Bobin g\u00fcc\u00fc di\u011fer y\u00fcklerle payla\u015f\u0131l\u0131yorsa, no-volt serbest b\u0131rakma belirsiz bir bant i\u00e7inde \u00e7al\u0131\u015fabilir. Sorun, no-volt serbest b\u0131rakmaya ek bir g\u00fc\u00e7 kayna\u011f\u0131 sa\u011flanarak \u00e7\u00f6z\u00fclebilir.<\/p>\n<h2>Referanslar<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.se.com\/\" rel=\"nofollow noopener\" target=\"_blank\">Schneider Electric \u2014 Undervoltage and Shunt Trip Release Teknik Dok\u00fcmantasyonu<\/a><\/li>\n<li><a href=\"https:\/\/www.abb.com\/\" rel=\"nofollow noopener\" target=\"_blank\">ABB \u2014 Devre Kesici Aksesuarlar\u0131: Undervoltage Releases<\/a><\/li>\n<li><a href=\"https:\/\/www.iec.ch\/\" rel=\"nofollow noopener\" target=\"_blank\">Uluslararas\u0131 Elektroteknik Komisyonu \u2014 IEC 60947-2 ve IEC 60947-4-1<\/a><\/li>\n<li><a href=\"https:\/\/eur-lex.europa.eu\/legal-content\/EN\/TXT\/?uri=CELEX:32006L0042\" rel=\"nofollow noopener\" target=\"_blank\">EUR-Lex \u2014 Makine Direktifi 2006\/42\/EC<\/a><\/li>\n<li><a href=\"https:\/\/www.hse.gov.uk\/\" rel=\"nofollow noopener\" target=\"_blank\">Sa\u011fl\u0131k ve G\u00fcvenlik Y\u00fcr\u00fctme Kurumu \u2014 Makine G\u00fcvenli\u011fi ve Beklenmedik Ba\u015flatma Rehberi<\/a><\/li>\n<\/ul>\n<h2>Sonu\u00e7<\/h2>\n<p>No-volt serbest b\u0131rakman\u0131n i\u015flevinin sadece ad\u0131na bakarak olduk\u00e7a kapsaml\u0131 oldu\u011funu d\u00fc\u015f\u00fcnebilirsiniz, ancak durum b\u00f6yle de\u011fildir. Y\u00fcksek fiyat\u0131 \u00fcr\u00fcn\u00fcn \u00f6neminin bir g\u00f6stergesi de\u011fildir, \u00e7\u00fcnk\u00fc voltaj\u0131 do\u011fru \u015fekilde kontrol etmez ve genel ama\u00e7l\u0131 bir yedek sistem de\u011fildir. Yapt\u0131\u011f\u0131 tek \u015fey, kontrol voltaj\u0131n\u0131n mevcut oldu\u011funu g\u00f6stermek ve voltaj g\u00fcvenli oldu\u011funda ve kontrol edilmesine gerek olmad\u0131\u011f\u0131nda ilerlemek i\u00e7in ba\u015flang\u0131\u00e7 ko\u015fulu olarak kullan\u0131lmas\u0131n\u0131 sa\u011flamakt\u0131r. No-volt serbest b\u0131rakma bu basit i\u015flevden b\u00fcy\u00fck fayda sa\u011flar. Bir g\u00fc\u00e7 kesintisinden sonra yeniden ba\u015flatabileceksiniz, d\u00fc\u015f\u00fck voltaj ko\u015fullar\u0131nda ba\u011flant\u0131y\u0131 kesebileceksiniz, kablo kopmas\u0131 durumunda no-volt serbest b\u0131rakmay\u0131 otomatik olarak kullanabileceksiniz ve son olarak, devre kesicinin y\u00fck olmadan kapanmas\u0131n\u0131 \u00f6nleyeceksiniz. Bir kontakt\u00f6r starter\u0131n\u0131z varsa, bu no-volt yeniden ba\u015flatma sistemi i\u00e7in ek bir maliyet yoktur. Bir devre kesiciniz varsa, bunu ayr\u0131 olarak sat\u0131n alman\u0131z gerekecektir. Sadece bobin ve y\u00fck voltaj\u0131n\u0131 e\u015fle\u015ftirin, gecikme ihtiyac\u0131n\u0131 belirleyin ve bobini zaman zaman test edin. Bu yakla\u015f\u0131m izlendi\u011fi s\u00fcrece, no-volt serbest b\u0131rakman\u0131n sonu\u00e7lar\u0131 sa\u011flanacak ve g\u00fcvenlik sisteminin sa\u011flamas\u0131 gereken i\u015flev sim\u00fcle edilmi\u015f olacakt\u0131r.<\/p>","protected":false},"excerpt":{"rendered":"<p>A no-volt release provides an answer to a question that every control panel manufacturer and machine designer must ask themselves at one point: &#8220;What will happen if power comes off and comes back on?&#8221; Saying that &#8220;the machine starts all by itself&#8221; is not acceptable for machines with rotating knives, loaded conveyors, and pressure pumps. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4241,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-4237","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/posts\/4237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/comments?post=4237"}],"version-history":[{"count":3,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/posts\/4237\/revisions"}],"predecessor-version":[{"id":4244,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/posts\/4237\/revisions\/4244"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/media\/4241"}],"wp:attachment":[{"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/media?parent=4237"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/categories?post=4237"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/tags?post=4237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}