{"id":4694,"date":"2026-11-08T13:38:28","date_gmt":"2026-11-08T13:38:28","guid":{"rendered":"https:\/\/huyuglobal.com\/?p=4694"},"modified":"2026-11-08T13:38:30","modified_gmt":"2026-11-08T13:38:30","slug":"what-is-a-thermal-magnetic-circuit-breaker","status":"publish","type":"post","link":"https:\/\/huyuglobal.com\/tr\/blog\/what-is-a-thermal-magnetic-circuit-breaker\/","title":{"rendered":"Termal Manyetik Devre Kesici Nedir?"},"content":{"rendered":"<p><a href=\"https:\/\/huyuglobal.com\/tr\/product\/exm3-mccb\/\">Termal Manyetik Devre Kesiciler<\/a> (<strong>TM CB<\/strong>) devre kesicilerin en pop\u00fcler t\u00fcr\u00fcd\u00fcr ve bu cihazlarda kullan\u0131lan devrelerin neredeyse tamam\u0131 ticari olarak t\u00fcketicilere sunulmaktad\u0131r. Ancak, \u00e7o\u011fu t\u00fcketicinin bir TM CB'nin nas\u0131l \u00e7al\u0131\u015ft\u0131\u011f\u0131n\u0131 anlamamas\u0131 yayg\u0131nd\u0131r, bu nedenle sat\u0131n almadan \u00f6nce i\u015flevlerini anlamak \u00f6nemlidir. TM CB'nin iki t\u00fcr a\u00e7ma mekanizmas\u0131 vard\u0131r; s\u00fcrekli a\u015f\u0131r\u0131 y\u00fcklenmelere tepki veren \u201c\u0131s\u0131\u201d mekanizmas\u0131 ve k\u0131sa devre ko\u015fullar\u0131na tepki veren \u201cmanyetik\u201d mekanizma. Bu iki mekanizman\u0131n ayr\u0131m\u0131, son kullan\u0131c\u0131n\u0131n gereksiz a\u00e7ma ve\/veya yava\u015f a\u00e7ma nedenini belirlemesine yard\u0131mc\u0131 olur. Bu nedenle, TM CB'nizde gereksiz a\u00e7ma veya yava\u015f a\u00e7ma sorunlar\u0131 ya\u015f\u0131yorsan\u0131z, hangi a\u00e7ma mekanizmas\u0131n\u0131n \u00e7al\u0131\u015ft\u0131\u011f\u0131n\u0131 dikkate al\u0131n.<\/p>\n<blockquote><p><strong>K\u0131saca:<\/strong> TM CB, s\u00fcrekli a\u015f\u0131r\u0131 y\u00fcklenmeler nedeniyle zamanla (saniyelerden dakikalara kadar) b\u00fck\u00fclecek bir bimetalik \u015ferit ve ak\u0131m derecesinin katlar\u0131 a\u015f\u0131ld\u0131\u011f\u0131nda (C e\u011frisi i\u00e7in 5 ila 10 kat\u0131) milisaniyeler i\u00e7inde a\u00e7ma yapan bir solenoid kullan\u0131r. Is\u0131 mekanizmas\u0131, TM CB'nin kurulu oldu\u011fu kablonun termal derecesine dayal\u0131 ters zaman korumas\u0131 sa\u011flar. Manyetik mekanizma, a\u015f\u0131r\u0131 ak\u0131m a\u00e7ma durumuna neden oldu\u011funda \u0131s\u0131 mekanizmas\u0131na a\u00e7ma h\u0131z\u0131 ekler. TM CB konfig\u00fcrasyonu, ko\u015fullar gerektirdi\u011finde a\u00e7ma yapacak basit bir mekanik cihaz sa\u011flar, ek g\u00fc\u00e7 kayna\u011f\u0131 gerektirmez ve a\u00e7ma ayarlar\u0131nda sadece temel ayarlamalar yap\u0131l\u0131r. TM CB fiyatlar\u0131, mini cihazlar i\u00e7in $2'den 630 A'lik daha b\u00fcy\u00fck kal\u0131pl\u0131 cihazlar i\u00e7in $400'e kadar de\u011fi\u015fir. Elektronik a\u00e7ma \u00fcniteleri, TM CB ile ayn\u0131 i\u015flevi ak\u0131m trafosu teknolojisi ile sa\u011flar; ancak \u00e7ok daha y\u00fcksek sat\u0131n alma fiyatlar\u0131 (iki ila be\u015f kat) ve ayarlanabilir a\u00e7ma ayarlar\u0131, \u00f6l\u00e7\u00fcm ve kontrol devreleri gibi ek \u00f6zellikler gerektirir.<\/p><\/blockquote>\n<p>Bu makale, TM CB'nin nas\u0131l \u00e7al\u0131\u015ft\u0131\u011f\u0131, TM CB'leri tan\u0131mlamak i\u00e7in kullan\u0131lan temel semboller, TM CB'lerin izledi\u011fi a\u00e7ma e\u011frisi desenleri, TM CB ile Elektronik a\u00e7ma \u00fcniteleri ve sadece Manyetik cihazlar\u0131n kar\u015f\u0131la\u015ft\u0131rmas\u0131, TM CB'nin farkl\u0131 a\u00e7ma t\u00fcrlerinin nas\u0131l ve ne zaman kullan\u0131laca\u011f\u0131 ile cihazlar\u0131n maliyetleri hakk\u0131nda bilgi sa\u011flar.<\/p>\n<h2>Termal Manyetik Devre Kesicinin Tan\u0131m\u0131<\/h2>\n<p>Termal Manyetik Devre Kesici, iki farkl\u0131 a\u00e7ma y\u00f6ntemi i\u00e7eren ve hem \u0131s\u0131 hem de manyetik a\u015f\u0131r\u0131 y\u00fcke kar\u015f\u0131 koruma sa\u011flayan bir devre kesicidir. Bu iki y\u00f6ntem, ayr\u0131 odac\u0131klarda yer ald\u0131\u011f\u0131ndan ve elektrik sisteminden ge\u00e7en ayn\u0131 ak\u0131m \u00fczerinden \u00e7al\u0131\u015ft\u0131\u011f\u0131ndan cihaz\u0131 ba\u011f\u0131ms\u0131z olarak a\u00e7ar.<\/p>\n<p>Termal a\u00e7ma mekanizmas\u0131, farkl\u0131 termal genle\u015fme \u00f6zelliklerine sahip iki farkl\u0131 metalin bir araya getirilmesiyle olu\u015fan bimetalik \u015feritten olu\u015fur. \u015eeritten bir ak\u0131m ge\u00e7ti\u011finde, \u0131s\u0131 olu\u015fur ve bu da \u015feridin b\u00fck\u00fclmesine neden olur. \u00d6nceden belirlenmi\u015f bir b\u00fck\u00fclme derecesine ula\u015f\u0131ld\u0131\u011f\u0131nda, \u015ferit mandal\u0131 a\u00e7ar ve devreyi keser. Is\u0131nman\u0131n zaman almas\u0131 nedeniyle a\u00e7ma gecikir, ancak ak\u0131m artt\u0131k\u00e7a a\u00e7ma daha erken ger\u00e7ekle\u015fir. Bu \u00f6zellik ters zaman olarak bilinir ve besleme kablosunun a\u015f\u0131r\u0131 y\u00fckleri kesici a\u00e7\u0131lmadan ta\u015f\u0131mas\u0131na olanak tan\u0131r.<\/p>\n<p>Manyetik a\u00e7ma mekanizmas\u0131, devre kesiciyi a\u00e7mak i\u00e7in bir solenoid ve armatur kullan\u0131r. \u00d6nceden belirlenmi\u015f bir ak\u0131m seviyesine ula\u015f\u0131ld\u0131\u011f\u0131nda, solenoidin manyetik kuvveti armaturu yerinde tutan yay kuvvetini a\u015far ve b\u00f6ylece armatur mandala \u00e7arparak devre kesiciyi a\u00e7ar. Bu mekanizmada \u0131s\u0131nma ger\u00e7ekle\u015fmez, bu nedenle a\u00e7ma neredeyse an\u0131nda (genellikle 20 milisaniye i\u00e7inde) ger\u00e7ekle\u015fir. Bu nedenle manyetik mekanizma, kablo zarar g\u00f6rmeden \u00f6nce k\u0131sa devreyi temizler.<\/p>\n<p>Her iki mekanizma ayn\u0131 mandal \u00fczerinde \u00e7al\u0131\u015f\u0131r, bu nedenle cihaz bir b\u00fct\u00fcn olarak test edilebilir ve a\u00e7ma e\u011frisi iki ayr\u0131 \u00e7izgi g\u00f6sterir.<\/p>\n<h2>\u00c7al\u0131\u015fma Prensibi: uygulama ba\u015f\u0131na bir eleman, iki eleman\/model = termal + manyetik<\/h2>\n<p>Termal elemanlar kablo izolasyonunu modelleyerek, kal\u0131c\u0131 hasar olu\u015fmadan \u00f6nce belirli bir a\u015f\u0131r\u0131 y\u00fck\u00fc ta\u015f\u0131yabilir. Bimetalik \u015feritler, kabloyu korumak ve cihaz\u0131 korumamak i\u00e7in hasar noktas\u0131n\u0131n hemen alt\u0131nda a\u00e7ma yapacak \u015fekilde kalibre edilmi\u015ftir.<\/p>\n<p>Bu nedenle, termal elemanlar kas\u0131tl\u0131 olarak yava\u015f \u00e7al\u0131\u015f\u0131r, b\u00f6ylece kesiciler gereksiz yere a\u00e7madan koruma sa\u011flar. \u00d6rne\u011fin, 32 A\u2019lik bir kesici 40 A (\u00f6zellikle ba\u015flatma s\u0131ras\u0131nda) ta\u015f\u0131d\u0131\u011f\u0131nda a\u00e7mas\u0131 birka\u00e7 dakika s\u00fcrebilir \u2013 bu do\u011fru davran\u0131\u015ft\u0131r \u00e7\u00fcnk\u00fc 32 A dereceli kablolar, izolasyonun erimesi ger\u00e7ekle\u015fmeden \u00f6nce bu s\u00fcre boyunca 40 A\u2019y\u0131 ta\u015f\u0131yabilir.<\/p>\n<p>Manyetik eleman, saniyenin kesirinde ger\u00e7ekle\u015fen ar\u0131za\/patlama durumu i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015ft\u0131r ve kas\u0131tl\u0131 bir gecikmesi yoktur. Manyetik a\u00e7ma e\u015fi\u011fi, nominal ak\u0131m\u0131n bir kat\u0131d\u0131r ve bu nedenle motor uygulamas\u0131 i\u00e7in manyetik a\u00e7ma cihaz\u0131 se\u00e7ildi\u011finde, DC derecelendirmesinden ziyade e\u011fri harfine bakmak \u00f6nemlidir.<\/p>\n<p>\u00c7o\u011fu uygulama sorunu, termal ve manyetik trip ko\u015fullar\u0131n\u0131n \u00f6rt\u00fc\u015fmesinden kaynaklan\u0131r. Manyetik trip e\u015fik de\u011ferinin hemen \u00fczerinde olan bir ar\u0131za ak\u0131m\u0131, s\u0131cakl\u0131\u011fa ve kesicinin zaten bir y\u00fck ta\u015f\u0131y\u0131p ta\u015f\u0131mad\u0131\u011f\u0131na ba\u011fl\u0131 olarak termal veya manyetik eleman taraf\u0131ndan temizlenebilir (yani termal eleman, so\u011fukken oldu\u011fundan daha fazla \u0131s\u0131nm\u0131\u015fsa). Bir trip cihaz\u0131n\u0131n, nominal y\u00fck\u00fcn\u00fcn 1,3 kat\u0131nda nas\u0131l performans g\u00f6sterdi\u011fini g\u00f6zlemledi\u011finizde, tekrarlanabilir gereksiz trip sonu\u00e7lar\u0131 \u00e7\u0131karmak zordur (yani, tripin g\u00f6r\u00fcn\u00fcr bir neden olmadan ger\u00e7ekle\u015fti\u011fi durumlar). Ancak, bu fenomen, elektrik \u015fematik \u00e7izimlerinde devre kesici sembollerinin okunmas\u0131na bak\u0131larak daha iyi anla\u015f\u0131labilir.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4696\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/11\/The-Symbol-and-How-to-Read-It-on-a-Drawing.webp\" alt=\"Sembol ve \u00c7izimde Nas\u0131l Okunur\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>Sembol ve \u00c7izimde Nas\u0131l Okunur<\/h2>\n<p>Elektrik \u015fematik \u00e7izimlerinde, bir devre kesici i\u00e7in standart sembol, \u00e7al\u0131\u015fma noktas\u0131nda \u00e7ok k\u00fc\u00e7\u00fck bir kare veya yar\u0131m daire ile g\u00f6sterilen bir anahtar konta\u011f\u0131d\u0131r. Termal manyetik devre kesici versiyonu, her bir bile\u015fen i\u00e7in ek i\u015faretler ekler. Termal bile\u015fen, Uluslararas\u0131 Elektroteknik Komisyon 60617 Standartlar\u0131na uygun olarak k\u00fc\u00e7\u00fck bir dikd\u00f6rtgen veya C \u015fekli olarak g\u00f6r\u00fcn\u00fcrken, manyetik bile\u015fen \u00e7ok k\u00fc\u00e7\u00fck bir halka veya yar\u0131m daire olarak g\u00f6r\u00fcn\u00fcr (her iki bile\u015fen de ayn\u0131 kutupta bulunur).<\/p>\n<p>Bir devre kesicinin \u015femati\u011fini incelerken kontrol edilmesi kritik olan \u00fc\u00e7 \u015fey vard\u0131r: sembol bir anahtarlama m\u0131 yoksa kesici\/ay\u0131r\u0131c\u0131 anahtar\u0131 m\u0131? Anahtar ve kesici ay\u0131r\u0131c\u0131 anahtarlar \u00e7ok benzer g\u00f6r\u00fcn\u00fcr, ancak bu cihaz t\u00fcrlerinden yaln\u0131zca biri otomatik koruma sa\u011flar. Kontrol edilmesi gereken ikinci kritik bilgi, kesiciyi \u00e7al\u0131\u015ft\u0131ran kutuplar\u0131n birlikte ba\u011flan\u0131p ba\u011flanmad\u0131\u011f\u0131d\u0131r.<\/p>\n<p>\u00dc\u00e7 fazl\u0131 bir devre kesicide, t\u00fcm \u00e7al\u0131\u015fma kutuplar\u0131n\u0131n e\u015fzamanl\u0131 a\u00e7\u0131lmas\u0131 kritik \u00f6neme sahiptir (birbirine ba\u011fl\u0131 kutup mekanizmalar\u0131n\u0131 g\u00f6steren kesikli \u00e7izgi ile g\u00f6sterilmelidir). \u0130ncelenmesi gereken \u00fc\u00e7\u00fcnc\u00fc kritik bilgi, devre kesici sembol\u00fcn\u00fcn bir e\u011fri referans\u0131na sahip olup olmad\u0131\u011f\u0131d\u0131r. E\u011frisiz bir kesici sembol\u00fc, cihaz hakk\u0131nda herhangi bir spesifikasyon vermemi\u015ftir.<\/p>\n<p>Tek kutuplu bir g\u00f6sterimde, kesici termal manyetik detay\u0131 genellikle \u00e7apraz \u00e7izgi \u00e7ekilmi\u015f bir kare veya \u00e7izgi \u00e7ekilmi\u015f dikd\u00f6rtgen olarak olduk\u00e7a basitle\u015ftirilir. Tek hat \u00e7iziminde g\u00f6sterildi\u011fi gibi, termal manyetik sembol g\u00f6sterilmez, bu da yerle\u015fim ama\u00e7lar\u0131 i\u00e7in yeterli bilgi sa\u011flar. Ancak, bir koruma \u00e7al\u0131\u015fmas\u0131 yap\u0131l\u0131rken, koruma \u00e7al\u0131\u015fmas\u0131 bir e\u011fri ve ayarlar\u0131 gerektirir ve kesicinin sembolik g\u00f6sterimini gerektirmez.<\/p>\n<p>\u00c7izim yerine, \u00fcreticiler ayr\u0131ca cihaz\u0131n yan\u0131na mini bir e\u011fri de basarlar. Mini e\u011fri, \u00f6zellikle o cihaza \u00f6zg\u00fc oldu\u011fu i\u00e7in cihazla \u00e7ok daha alakal\u0131d\u0131r. Bir cihaz\u0131n mini e\u011frisinde C e\u011frisi derecesi ve 10 kA kesme kapasitesi derecesi varsa, ar\u0131za seviyesi bu cihazda 10 kA'n\u0131n alt\u0131ndayken se\u00e7im yapmak i\u00e7in gereken t\u00fcm bilgiler budur.<\/p>\n<h2>Trip E\u011frisi: B, C, D ve Say\u0131lar\u0131n Anlam\u0131<\/h2>\n<p>D\u00f6rt trip e\u011frisi, B, C, D ve bunlara kar\u015f\u0131l\u0131k gelen say\u0131lar, manyetik trip aral\u0131\u011f\u0131n\u0131 nominal ak\u0131m\u0131n kat\u0131 olarak g\u00f6sterir. Trip e\u011frisi ile ili\u015fkili harf, hangi mini devre kesicinin kullan\u0131laca\u011f\u0131n\u0131 belirlemek i\u00e7in en \u00f6nemli bilgidir.<\/p>\n<table>\n<thead>\n<tr>\n<th>E\u011fri<\/th>\n<th>Manyetik Trip Aral\u0131\u011f\u0131<\/th>\n<th>Tipik Uygulama<\/th>\n<th>Toleransl\u0131 Y\u00fck<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>B<\/td>\n<td>Nominal ak\u0131m\u0131n 3-5 kat\u0131<\/td>\n<td>diren\u00e7li y\u00fckler, uzun hatlar, ayd\u0131nlatma<\/td>\n<td>Az veya hi\u00e7 giri\u015f ak\u0131m\u0131 yok. H\u0131zl\u0131 trip temizlemeye g\u00fc\u00e7l\u00fc e\u011filim.<\/td>\n<\/tr>\n<tr>\n<td>C<\/td>\n<td>Nominal ak\u0131m\u0131n 5-10 kat\u0131<\/td>\n<td>genel ama\u00e7l\u0131, kar\u0131\u015f\u0131k y\u00fckler, k\u00fc\u00e7\u00fck motorlar<\/td>\n<td>Orta derecede giri\u015f ak\u0131m\u0131.<\/td>\n<\/tr>\n<tr>\n<td>D<\/td>\n<td>Nominal ak\u0131m\u0131n 10-20 kat\u0131<\/td>\n<td>trafolar, motorlar, kaynak makineleri, pompalar<\/td>\n<td>Rahats\u0131z edici trip olmadan b\u00fcy\u00fck giri\u015f ak\u0131m\u0131.<\/td>\n<\/tr>\n<tr>\n<td>K<\/td>\n<td>10-14 kat, termal 1-2<\/td>\n<td>Y\u00fcksek kalk\u0131\u015f ak\u0131ml\u0131 motorlar<\/td>\n<td>Nominale yak\u0131n s\u00fcrekli a\u015f\u0131r\u0131 y\u00fck.<\/td>\n<\/tr>\n<tr>\n<td>Z<\/td>\n<td>Nominal ak\u0131m\u0131n 2-3 kat\u0131<\/td>\n<td>elektronik, yar\u0131 iletken korumas\u0131<\/td>\n<td>Giri\u015f ak\u0131m\u0131 olmadan \u00e7ok hassas.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Her e\u011fri iki alan i\u00e7erir. Her e\u011frinin termal alan\u0131, bir cihaz i\u00e7in ak\u0131m aral\u0131\u011f\u0131n\u0131 kapsar = <span style=\"color: #c00000;\">nominal ak\u0131m\u0131n\u0131n 1,13 ila 1,45 kat\u0131 aras\u0131nda<\/span>. Cihaz, nominal ak\u0131m\u0131n\u0131n 1,13 kat\u0131nda trip yapmamal\u0131 ve IEC 60898-1 gereksinimlerine g\u00f6re nominal ak\u0131m\u0131n\u0131n 1,45 kat\u0131nda her zaman 1 saat i\u00e7inde trip yapmal\u0131d\u0131r. Manyetik b\u00f6lgenin ba\u015flad\u0131\u011f\u0131 e\u015fik, e\u011frinin grafikteki d\u00fcz dikey noktas\u0131d\u0131r; b\u00f6ylece elektrik kullan\u0131m\u0131 i\u00e7in trip s\u00fcreleri, elektrik servisi bu e\u015fik de\u011ferinin ne kadar \u00fczerinde olursa olsun 20 milisaniyeden az kal\u0131r.<\/p>\n<p>Bu iki alan aras\u0131nda, trip cihaz\u0131n\u0131n elektrik servisini alabilece\u011fi veya alamayaca\u011f\u0131 bir ge\u00e7i\u015f band\u0131 vard\u0131r. Bir trip e\u011frisi se\u00e7mek, korunan y\u00fck\u00fcn g\u00f6rd\u00fc\u011f\u00fc ilk impulsla ilgili olarak bu ge\u00e7i\u015f band\u0131n\u0131n nerede ayarlanaca\u011f\u0131yla daha \u00e7ok ilgilidir.<\/p>\n<p>\u00d6rne\u011fin, isim plakas\u0131ndaki nominal ak\u0131m\u0131n\u0131n sekiz kat\u0131n\u0131 (8x) ilk impuls i\u00e7in (yani \u00bd saniye s\u00fcreyle) gerektiren bir pompa, C e\u011frisi yerine D veya K e\u011frileri gibi manyetik e\u015fik ayar\u0131 8x'ten b\u00fcy\u00fck olan bir trip e\u011frisi gerektirir.<\/p>\n<p>Trip e\u011frisi ayr\u0131ca devre kesici taraf\u0131ndan korunabilecek maksimum kablo uzunlu\u011funu da belirler. Uzun kablo hatlar\u0131, kablo hatt\u0131n\u0131n uzak ucundaki ar\u0131za ak\u0131m\u0131n\u0131 azaltacak kadar empedans ya\u015far; dolay\u0131s\u0131yla, azalt\u0131lm\u0131\u015f uzun hat ar\u0131za ak\u0131m\u0131 trip e\u011frisinin manyetik e\u015fi\u011finin alt\u0131na d\u00fc\u015ferse, devre kesici hemen trip yapmaz. Bu nedenle, \u00e7o\u011fu uzun ayd\u0131nlatma devresi, kablolar\u0131n uzak u\u00e7lar\u0131n\u0131 eri\u015filebilir tutmak i\u00e7in daha d\u00fc\u015f\u00fck bir kat fakt\u00f6r\u00fcnde trip yapabilen B trip e\u011frilerini kullan\u0131r.<\/p>\n<h2>Termal Manyetik Kesiciler ve Elektronik Trip \u00dcniteleri<\/h2>\n<p>Elektronik trip \u00fcniteleri, termal manyetik devre kesicilerin (MCB) yerine kullan\u0131labilecek bir se\u00e7enek olmas\u0131na ra\u011fmen, b\u00fcy\u00fck fark elektronik trip \u00fcnitelerinin termal manyetik devre kesicilerden \u00e7ok daha fazlas\u0131n\u0131 yapabilme yetene\u011fine sahip olmas\u0131d\u0131r.<\/p>\n<p>Bir elektronik trip \u00fcnitesi, gelen elektrik hizmetini dahili ak\u0131m trafolar\u0131 ile \u00f6l\u00e7er, bu gelen elektrik hizmetinin dalga formunu dijitalle\u015ftirir (d\u00f6n\u00fc\u015ft\u00fcr\u00fcr) ve bilgisayar (bilgisayar program yaz\u0131l\u0131m\u0131) arac\u0131l\u0131\u011f\u0131yla ne zaman a\u00e7aca\u011f\u0131n\u0131 belirler. Elektronik trip \u00fcnitesi kullan\u0131m\u0131, kullan\u0131c\u0131ya uzun zaman ayar\u0131 (I), k\u0131sa zaman ayar\u0131 (Im), k\u0131sa zaman gecikmesi (tsd) ve toprak ar\u0131za eleman\u0131 se\u00e7me esnekli\u011fi sa\u011flar (daha b\u00fcy\u00fck elektronik trip \u00fcnitelerinde ayr\u0131ca izleme ve ileti\u015fim yetene\u011fi de olabilir).<\/p>\n<p>Termal manyetik devre kesicinin ayarlanabilir olmad\u0131\u011f\u0131 a\u015fa\u011f\u0131daki tablo ile do\u011frulanm\u0131\u015ft\u0131r:<\/p>\n<p>Termal Manyetik Devre Kesici vs. Elektronik Devre Kesici<\/p>\n<table>\n<tbody>\n<tr>\n<td>Ayarlanabilirlik<\/td>\n<td>Sabit E\u011fri<\/td>\n<td>Ayarlanabilir: Ir, Im, tsd, Toprak Ar\u0131zas\u0131<\/td>\n<\/tr>\n<tr>\n<td>Do\u011fruluk<\/td>\n<td>\u00b110%-20%<\/td>\n<td>\u00b15% veya Daha \u0130yi Do\u011fruluk<\/td>\n<\/tr>\n<tr>\n<td>Yard\u0131mc\u0131 Besleme<\/td>\n<td>Yok<\/td>\n<td>\u00c7o\u011fu Tasar\u0131mda Devreden Kendi G\u00fcc\u00fcn\u00fc Sa\u011flar<\/td>\n<\/tr>\n<tr>\n<td>\u00d6l\u00e7\u00fcm\/\u0130leti\u015fim<\/td>\n<td>Yok<\/td>\n<td>Ak\u0131m\/Gerilim\/Enerji, Modbus\/Ethernet<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cakl\u0131kta A\u00e7ma Davran\u0131\u015f\u0131<\/td>\n<td>Erken A\u00e7ma ve G\u00fc\u00e7 Azaltma Uygulan\u0131r<\/td>\n<td>S\u0131cakl\u0131k Kompansasyonlu<\/td>\n<\/tr>\n<tr>\n<td>250A Fiyat\u0131<\/td>\n<td>$120-$400<\/td>\n<td>$300-$800<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Termal manyetik ve elektronik devre kesiciler kar\u015f\u0131la\u015ft\u0131r\u0131ld\u0131\u011f\u0131nda, termal manyetik devrelerin birka\u00e7 belirgin avantaj\u0131 vard\u0131r:<\/p>\n<ol>\n<li>Termal manyetik cihazlar\u0131n \u00e7al\u0131\u015fmas\u0131 i\u00e7in g\u00fc\u00e7 kayna\u011f\u0131 gerekmez. Elektrik devresi kapal\u0131 olsa bile \u00e7al\u0131\u015fabilirler.<\/li>\n<li>Termal manyetik cihazlarda elektronik bile\u015fen bulunmad\u0131\u011f\u0131ndan, y\u00fcksek \u0131s\u0131 veya y\u00fcksek harmonik ortamlarda ar\u0131za yapma olas\u0131l\u0131klar\u0131 \u00e7ok daha d\u00fc\u015f\u00fckt\u00fcr.<\/li>\n<li>Termal manyetik ve elektronik devre kesiciler aras\u0131ndaki fiyat fark\u0131 \u00f6nemlidir. Asl\u0131nda, termal manyetik cihazlar\u0131n fiyat\u0131 genellikle <span style=\"color: #c00000;\">elektronik cihazlar\u0131n fiyat\u0131n\u0131n \u00fc\u00e7te biri kadard\u0131r<\/span> ki bu, \u00e7ok say\u0131da cihaz gerektiren uygulamalar i\u00e7in \u00f6nemlidir. Baz\u0131 durumlarda bir ana devre kesiciden 40 veya daha fazla \u00e7\u0131k\u0131\u015f kablosu olabilir.<\/li>\n<\/ol>\n<p>Elektronik devre kesiciler, m\u00fchendislik se\u00e7icili\u011fi gerektiren uygulamalar i\u00e7in faydal\u0131d\u0131r. Bir \u00f6rnek, ana kesicinin bir besleyici kesicinin ar\u0131zay\u0131 temizlemesi i\u00e7in zaman tan\u0131mas\u0131n\u0131 sa\u011flayan k\u0131sa zaman gecikmesidir. Bu, bir tesisin tek bir motor ar\u0131zas\u0131 nedeniyle t\u00fcm pano kayb\u0131n\u0131 \u00f6nlemesini sa\u011flar.<\/p>\n<p>Bir devre kesiciye se\u00e7icilik m\u00fchendisli\u011fi yapabilme yetene\u011fi elektronik cihazlar\u0131n do\u011fas\u0131nda vard\u0131r ve bu nedenle genellikle ana giri\u015fler olarak kullan\u0131l\u0131rlar, termal manyetik kesiciler ise besleyici uygulamalarda kullan\u0131l\u0131r. Se\u00e7ici se\u00e7eneklerin gerekmedi\u011fi uygulamalarda, ayarlanabilir termal manyetik trip ayarlar\u0131na sahip kal\u0131pl\u0131 kutu kesiciler gibi daha d\u00fc\u015f\u00fck maliyetli se\u00e7enekler vard\u0131r. Bunlar, elektronik devre kesicilerle ayn\u0131 i\u015flevselli\u011fi \u00f6nemli \u00f6l\u00e7\u00fcde daha d\u00fc\u015f\u00fck maliyetle sa\u011flar.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4697\" src=\"https:\/\/huyuglobal.com\/wp-content\/uploads\/2026\/11\/Whats-the-Difference-Between-Magnetic-and-Thermal-Magnetic-Circuit-Breakers.webp\" alt=\"Manyetik ve Termal Manyetik Devre Kesiciler Aras\u0131ndaki Fark Nedir\" width=\"1448\" height=\"1086\" \/><\/p>\n<h2>Manyetik ve Termal Manyetik Devre Kesiciler Aras\u0131ndaki Fark Nedir?<\/h2>\n<p>Manyetik sadece olan bir elektrik devre koruyucu (ayn\u0131 zamanda \u201ckesici\u201d olarak da bilinir) temelde sadece elektromanyetik anahtar (solenoid) ve ba\u015fka hi\u00e7bir \u015feyden olu\u015fur. Sadece k\u0131sa devre ar\u0131zalar\u0131n\u0131 tespit edebilir; bu nedenle a\u015f\u0131r\u0131 y\u00fcklenme durumlar\u0131n\u0131 tespit edemez ve tamamlay\u0131c\u0131 koruyucu olarak kullan\u0131l\u0131r.<\/p>\n<p>Bu iki t\u00fcr elektrik devre koruma \u00fcnitesi aras\u0131ndaki fark teknikten \u00e7ok d\u00fczenleyicidir. Kuzey Amerika i\u00e7in UL 1077 standard\u0131, manyetik sadece devre koruyucular\u0131 \u201ctamamlay\u0131c\u0131 koruyucular\u201d olarak tan\u0131mlar ve bunlar bir dal devre koruma sistemi par\u00e7as\u0131 olarak kullan\u0131labilir, ancak <span style=\"color: #c00000;\">dal devre koruma cihaz\u0131 olarak kullan\u0131lmalar\u0131na izin verilmez<\/span> \u00e7\u00fcnk\u00fc a\u015f\u0131r\u0131 y\u00fckler i\u00e7in test edilmemi\u015flerdir.<\/p>\n<p>UL 489 veya IEC 60947-2 standartlar\u0131na uygun cihazlar her iki bile\u015feni (manyetik anahtar ve a\u015f\u0131r\u0131 y\u00fck tespit mekanizmas\u0131) i\u00e7erir ve dal devre koruma cihaz\u0131 olarak kullan\u0131lmalar\u0131na izin verilir. Her iki t\u00fcr cihaz\u0131n ger\u00e7ek boyut ve \u015fekli \u00e7ok yak\u0131n olmas\u0131na ra\u011fmen, aralar\u0131nda b\u00fcy\u00fck yasal ve d\u00fczenleyici farklar vard\u0131r.<\/p>\n<p>Manyetik sadece devre koruyucular, a\u015f\u0131r\u0131 y\u00fck koruma mekanizmas\u0131n\u0131n ba\u015fka bir yerde mevcut oldu\u011fu durumlarda kullan\u0131l\u0131r; \u00f6rne\u011fin kendi termal korumas\u0131 olan ekipmanlarda, h\u0131zl\u0131 ak\u0131m bo\u015falmas\u0131n\u0131n istendi\u011fi yar\u0131 iletken devrelerde veya sabit DC ak\u0131m kullan\u0131lan baz\u0131 uygulamalarda. Tipik bir ev da\u011f\u0131t\u0131m panosu bu kategorilere girmez ve bu nedenle, bir manyetik sadece cihaz da\u011f\u0131t\u0131m panosunu korumak i\u00e7in kullan\u0131l\u0131rsa, y\u00fck\u00fc ta\u015f\u0131yan iletken a\u015f\u0131r\u0131 y\u00fck ko\u015fullar\u0131 nedeniyle a\u015f\u0131r\u0131 \u0131s\u0131nmaya kar\u015f\u0131 korunmam\u0131\u015f olur.<\/p>\n<p>Piyasada \u201cmanyetik kesici\u201d terimiyle ilgili b\u00fcy\u00fck bir kafa kar\u0131\u015f\u0131kl\u0131\u011f\u0131 vard\u0131r. Bir\u00e7ok ki\u015fi bu terimi manyetik eleman kullanan herhangi bir kesici i\u00e7in kullan\u0131r; bu, her termal manyetik tip kesiciyi i\u00e7erir. Bu uygulama sat\u0131\u015f literat\u00fcr\u00fcnde yayg\u0131nd\u0131r ve ayn\u0131 terminolojiyi kullanan farkl\u0131 sertifika t\u00fcrlerine sahip \u00fcr\u00fcnlerin ay\u0131rt edilmesini zorla\u015ft\u0131r\u0131r.<\/p>\n<h2>Termal Manyetik Devre Kesici ve Kal\u0131pl\u0131 Kasa Devre Kesici<\/h2>\n<p>Termal manyetik devre kesiciler ile <a href=\"https:\/\/huyuglobal.com\/tr\/product\/hum8-mccb-breaker\/\">kal\u0131pl\u0131 kasa devre kesiciler<\/a> aras\u0131ndaki kar\u015f\u0131la\u015ft\u0131rma z\u0131t gibi g\u00f6r\u00fcnse de, asl\u0131nda \u00f6yle de\u011fildir ve bu kar\u015f\u0131la\u015ft\u0131rman\u0131n arama sonu\u00e7lar\u0131nda yap\u0131lmas\u0131n\u0131n nedeni, arama yapanlar\u0131n b\u00f6yle varsaymas\u0131d\u0131r.<\/p>\n<p>Temelde, bir MCCB, muhafazas\u0131n\u0131n maksimum derecesine sahip olacak \u015fekilde tasarlanm\u0131\u015f bir kasad\u0131r; ancak devre kesicinin elektriksel derecesi, kendi i\u00e7sel a\u00e7ma teknolojisine g\u00f6re tan\u0131mlan\u0131r. Bu nedenle, \u2018termal manyetik\u2019 veya \u2018elektronik\u2019 olabilir ve her iki t\u00fcr de olduk\u00e7a yayg\u0131n olarak kullan\u0131l\u0131r.<\/p>\n<p>\u00d6rne\u011fin, termal manyetik a\u00e7ma \u00fcnitesine sahip 250 A Kal\u0131pl\u0131 Kasa Kesici (\u2018MCCB\u2019), ayn\u0131 zamanda Kal\u0131pl\u0131 Kasa Devre Kesici (\u2018MCCB\u2019) tan\u0131m gereksinimlerini de kar\u015f\u0131lar. Ayn\u0131 kasa tipi elektronik a\u00e7ma \u00fcnitesi ile termal manyetik olmayacak, ancak yine de \u2018MCCB\u2019 olarak s\u0131n\u0131fland\u0131r\u0131lacakt\u0131r.<\/p>\n<p>Pratikte, bir spesifikasyonun hem \u00e7er\u00e7eve tipini hem de kesme teknolojisini tan\u0131mlamas\u0131 \u00f6nemlidir. \u2018250 A MCCB\u2019 olarak belirtilen bir \u00e7izelge \u00e7er\u00e7eve tipini tan\u0131mlar, ancak sa\u011flanan koruma ile ilgili herhangi bir bilgi vermez. Bu, iki farkl\u0131 tedarik\u00e7inin \u00e7izelgelerinde \u00e7ok farkl\u0131 davran\u0131\u015flara sahip cihazlarla belirtilen bir sat\u0131r\u0131 teklif edebilece\u011fi anlam\u0131na gelir.<\/p>\n<p>Davran\u0131\u015f kar\u015f\u0131la\u015ft\u0131rmas\u0131 <a href=\"https:\/\/huyuglobal.com\/tr\/blog\/what-is-mccb-and-mcb\/\">MCCB'ler ve <\/a><a href=\"https:\/\/huyuglobal.com\/tr\/mcb-manufacturer\/\">mini devre kesiciler<\/a> ayn\u0131 konuyu farkl\u0131 a\u00e7\u0131lardan ele al\u0131r ve her iki raporu birlikte okumak faydal\u0131d\u0131r \u00e7\u00fcnk\u00fc bu iki cihaz t\u00fcr\u00fc genellikle proje \u00e7izelgelerinde birle\u015ftirilir.<\/p>\n<h2>Her T\u00fcr\u00fcn Kullan\u0131ld\u0131\u011f\u0131 Yerler<\/h2>\n<p>Termal manyetik cihazlar, y\u00fck\u00fcn nispeten \u00f6ng\u00f6r\u00fclebilir oldu\u011fu, a\u015f\u0131r\u0131 y\u00fck miktar\u0131n\u0131n s\u0131n\u0131rland\u0131r\u0131labildi\u011fi, ar\u0131za ak\u0131m\u0131n\u0131n \u00f6zellikle y\u00fcksek olmad\u0131\u011f\u0131 ve y\u00fck merkezinde birka\u00e7 devre bulundu\u011fu son devre korumas\u0131 ve alt ana devrelerde yayg\u0131n olarak kullan\u0131l\u0131r; bu nedenle basit, d\u00fc\u015f\u00fck maliyetli pasif bir cihaz uygun m\u00fchendislik \u00e7\u00f6z\u00fcm\u00fcd\u00fcr.<\/p>\n<p>Tipik bir konut y\u00fck devresi, 63 A ana \u015falter ve C e\u011frili \u00e7oklu mini devre kesicilere sahip olacakt\u0131r, hepsi termal manyetiktir.<\/p>\n<p>Ticari pano taraf\u0131ndan, priz devrelerine RCD (Art\u0131k Ak\u0131m Cihaz\u0131) veya RCBO (A\u015f\u0131r\u0131 Ak\u0131m Korumas\u0131 ile Art\u0131k Ak\u0131m Devre Kesici) eklenir ve di\u011fer t\u00fcm koruma sadece termal manyetik olarak tutulur. Bir Makine Paneli i\u00e7in, motorun bilinen kalk\u0131\u015f ak\u0131m\u0131 ve motorun kalk\u0131\u015f s\u00fcresi i\u00e7in D e\u011frisi veya ayarlanabilir manyetik ayar ile kapsama nedeniyle 100 A Termal Manyetik kesmeli Kal\u0131pl\u0131 Kasa Devre Kesici bulunur.<\/p>\n<p>Elektronik kesme cihazlar\u0131, bir tesisin ana giri\u015f beslemesinde ve alt\u0131ndaki cihazlarla koordinasyon sa\u011flanmas\u0131 gereken besleyicilerde ve enerji y\u00f6netimi gibi metriklerin izlenmesi gereken her yerde kullan\u0131l\u0131r. Ayr\u0131ca jenerat\u00f6rlerde ve ekipman\u0131n devreye al\u0131nmas\u0131ndan sonra kesme ayarlar\u0131n\u0131n de\u011fi\u015ftirilmesi gereken devrelerde, cihaz\u0131n de\u011fi\u015ftirilmesine gerek kalmadan bulunur.<\/p>\n<p>Bir\u00e7ok projedeki \u00f6nceki deneyimlerden, normal model 250 A alt\u0131ndaki t\u00fcm uygulamalarda se\u00e7icilik i\u00e7in m\u00fchendislik yap\u0131lmad\u0131k\u00e7a termal manyetik kullan\u0131m\u0131, 400 A \u00fczerindeki t\u00fcm uygulamalarda elektronik kesme kullan\u0131m\u0131 ve 250 A ile 400 A aras\u0131ndaki uygulamalarda her iki t\u00fcr\u00fcn kar\u0131\u015f\u0131m\u0131d\u0131r. Bu nedenle bu model olumsuz de\u011fildir, \u00f6nceki on y\u0131l i\u00e7inde \u00fcretilen \u00e7o\u011fu pano bu \u015fekilde a\u00e7\u0131klan\u0131r. Da\u011f\u0131t\u0131m Panolar\u0131nda kullan\u0131lan Kal\u0131pl\u0131 Kasa Devre Kesiciler, tam da bu nedenle her iki versiyonda da \u00fcretilmi\u015ftir.<\/p>\n<p>Yukar\u0131daki cihaz fiyatlar\u0131 kar\u015f\u0131la\u015ft\u0131rmas\u0131nda, Termal manyetik tip t\u00fcm cihazlar i\u00e7in en uygun fiyatl\u0131 se\u00e7enektir; ancak, 250 amper \u00e7er\u00e7evede Termal Manyetik'ten Elektronik Trip'e fiyat art\u0131\u015f\u0131 aras\u0131ndaki fark, 630 amper \u00e7er\u00e7evedeki farktan daha k\u00fc\u00e7\u00fckt\u00fcr, bu da genellikle i\u015flevin fiyat yerine tercih sebebi olaca\u011f\u0131 anlam\u0131na gelir. 20 \u00e7\u0131k\u0131\u015f devresi olan bir pano kuruyorsan\u0131z ve devre se\u00e7icili\u011fine ihtiyac\u0131n\u0131z yoksa, bu devrelerde elektronik trip kullanmak i\u00e7in bir neden yoktur.<\/p>\n<h2>Maliyeti<\/h2>\n<p>Cihaz maliyetlerine ek olarak, genellikle g\u00f6zden ka\u00e7an iki maliyet vard\u0131r: Devreye Alma ve Yedek Par\u00e7alar. Termal Manyetik cihaz i\u00e7in devreye alma s\u0131ras\u0131nda cihaz\u0131n ayarlanmas\u0131 gerekmezken, Elektronik Trip cihaz\u0131 i\u00e7in ayar\u0131n kaydedilmesini gerektiren bir devreye alma s\u00fcreci olacakt\u0131r ve bu da cihaz ba\u015f\u0131na ek M\u00fchendislik maliyetlerine yol a\u00e7acakt\u0131r.<\/p>\n<p>Yedek Par\u00e7alar ile ili\u015fkili ikinci maliyet, de\u011fi\u015ftirilebilir mod\u00fcl olarak temin edilen Elektronik Trip'tir ve Termal Manyetik cihazdan farkl\u0131 par\u00e7a numaras\u0131 ve teslim s\u00fcresine sahiptir; Termal Manyetik cihaz ise t\u00fcm cihaz montaj\u0131 olarak temin edilir. Ancak, baz\u0131 Kal\u0131pl\u0131 Kasa Kesiciler modelleri, cihaz\u0131n iki bile\u015feni farkl\u0131 maliyet fakt\u00f6rlerine g\u00f6re fiyatland\u0131r\u0131ld\u0131\u011f\u0131 i\u00e7in \u00e7er\u00e7eve ve devre kesici tipi i\u00e7in ayr\u0131 fiyatland\u0131rma ile sat\u0131lmaktad\u0131r.<\/p>\n<h2>Nerede <strong>HUYU<\/strong> uyar<\/h2>\n<p>Hem minyat\u00fcr hem de <a href=\"https:\/\/huyuglobal.com\/tr\/molded-case-circuit-breaker-supplier\/\">kal\u0131pl\u0131 kasa termal manyetik trip devre kesicileri \u00fcretiyoruz<\/a> 1A ile 1600A aras\u0131nda de\u011fi\u015fen de\u011ferlerle. T\u00fcm \u00fcr\u00fcnlerimiz IEC standartlar\u0131na, \u00f6zellikle IEC 60898-1 ve IEC 60947-2 ile UL 489'a uygundur. \u00dcr\u00fcnlerimizin b\u00fcy\u00fck \u00e7o\u011funlu\u011fu, m\u00fc\u015fterilerin tek bir \u00fcreticiden birden fazla \u00fcr\u00fcn kullanabilmek istedi\u011fi da\u011f\u0131t\u0131m panolar\u0131, makine kontrol panelleri ve OEM ekipmanlar\u0131 gibi \u00e7e\u015fitli uygulamalarda kullan\u0131lacakt\u0131r; b\u00f6ylece bireysel bir \u00fcr\u00fcn\u00fcn daha y\u00fcksek teknik \u00f6zelliklerini e\u015fle\u015ftirme endi\u015fesi ortadan kalkar.<\/p>\n<p>Minyat\u00fcr devre kesici serimiz, B, C ve D e\u011frileri dahil \u00e7e\u015fitli e\u011fri tiplerini i\u00e7erir; ve 18 mm geni\u015flikte 6 kA ile 10 kA aras\u0131nda derecelendirilmi\u015ftir. Her devre kesici, trip e\u011frisi tipi ile i\u015faretlenmi\u015f olup manyetik e\u015fik belirtilmi\u015f, ima edilmemi\u015ftir. Ayr\u0131ca, kal\u0131pl\u0131 kasa devre kesici serimiz 16A ile 250A aras\u0131nda derecelendirilmi\u015f \u00fcr\u00fcnler i\u00e7erir ve her \u00e7er\u00e7eve i\u00e7in birden fazla ayar sunarak \u00e7e\u015fitli kablo boyutlar\u0131n\u0131n korunmas\u0131na olanak tan\u0131r.<\/p>\n<p>HUYU'nun iddia etmedi\u011fi \u015fey, termal manyetik trip cihazlar\u0131n\u0131n elektronik trip cihazlar\u0131 ile ayn\u0131 i\u015flevselli\u011fi sa\u011flad\u0131\u011f\u0131d\u0131r. Termal Manyetik Trip Cihazlar\u0131 Anl\u0131k gecikme ayarlanamaz ve enerji t\u00fcketimini raporlayamaz. Projede bu iki \u00f6zellikten herhangi birinin gerekti\u011fi durumlarda do\u011fru \u00e7\u00f6z\u00fcm elektronik devre kesici olacakt\u0131r ve biz, ilk koordinasyon \u00e7al\u0131\u015fmas\u0131ndan sonra de\u011fi\u015ftirece\u011fimiz bir \u00fcr\u00fcn\u00fc teklif etmek yerine do\u011fru \u00e7\u00f6z\u00fcm\u00fc sa\u011flayaca\u011f\u0131z.<\/p>\n<h2>SSS<\/h2>\n<h3>Termal manyetik devre kesici ne i\u00e7in kullan\u0131l\u0131r?<\/h3>\n<p>Termal manyetik devre kesici, pasif bir cihazdan hem a\u015f\u0131r\u0131 ak\u0131m hem de k\u0131sa devre korumas\u0131 gerekti\u011finde kullan\u0131l\u0131r.<\/p>\n<p>Konut ve ticari da\u011f\u0131t\u0131m panolar\u0131nda, son devreler ar\u0131za korumas\u0131 ve t\u00fcm dal devresi i\u00e7in termal a\u015f\u0131r\u0131 y\u00fck korumas\u0131 sa\u011flamak amac\u0131yla termal ve manyetik devre kesiciler i\u00e7erir. Bu nedenle, bu t\u00fcr devre kesiciler, termal eleman kablo hasar g\u00f6rmeden \u00f6nce elektrik kablosunu veya son devreyi korurken, manyetik eleman k\u0131sa devre ar\u0131za ko\u015fullar\u0131ndan elektrik kablosunu veya son devreyi koruyabilir.<\/p>\n<h3>Manyetik devre kesici ile termal\/manyetik devre kesici aras\u0131ndaki fark nedir?<\/h3>\n<p>Manyetik devre kesici sadece bir solenoide sahip olan ve sadece k\u0131sa devre korumas\u0131 sa\u011flayan bir devre kesicidir. Termal\/manyetik devre kesiciler ise hem bir solenoid hem de bir bimetalik elemana sahip devre kesicilerdir. Termal\/manyetik devre kesiciler hem k\u0131sa devre korumas\u0131 hem de s\u00fcrekli a\u015f\u0131r\u0131 y\u00fck korumas\u0131 sa\u011flayabilir. Manyetik devre kesiciler tamamlay\u0131c\u0131 koruma olarak kabul edilir ve UL 1077 standartlar\u0131 alt\u0131nda sertifikaland\u0131r\u0131l\u0131rken, termal\/manyetik devre kesiciler hem termal hem manyetik trip fonksiyonlar\u0131 i\u00e7in test edildi\u011fi i\u00e7in dal devresi koruma cihaz\u0131 olarak kullan\u0131labilir.<\/p>\n<h3>Termal\/manyetik devre kesici nas\u0131l \u00e7al\u0131\u015f\u0131r?<\/h3>\n<p>Termal\/manyetik devre kesiciler, bir bimetalik \u015ferit ve bir solenoid bobin i\u00e7erir; b\u00f6ylece s\u00fcrekli bir a\u015f\u0131r\u0131 y\u00fck oldu\u011funda, bimetalik \u015ferit \u0131s\u0131n\u0131r ve \u015ferit b\u00fck\u00fclerek mandal\u0131 serbest b\u0131rak\u0131r. Devreyi a\u00e7ma s\u00fcresi, ak\u0131m miktar\u0131 artt\u0131k\u00e7a azal\u0131r \u00e7\u00fcnk\u00fc bobindeki ak\u0131m artt\u0131k\u00e7a bobinde manyetik kuvvet artar ve bu da bir armaturun bimetalik \u015feridi \u00e7ekerek mandala vurmas\u0131na neden olur; bu i\u015flem kontaklar\u0131 20 milisaniyeden k\u0131sa s\u00fcrede a\u00e7ar. Her iki eleman da tek bir mekanizma \u00fczerinde \u00e7al\u0131\u015f\u0131r, b\u00f6ylece herhangi bir eleman devre kesiciyi a\u00e7abilir.<\/p>\n<h3>Termal devre kesiciler nedir?<\/h3>\n<p>Termal devre kesiciler yaln\u0131zca bimetalik \u015feridin termal \u00f6zelliklerinden kaynaklanan \u0131s\u0131 etkisine dayan\u0131r. Bimetalik \u015ferit, ak\u0131m\u0131n \u0131s\u0131tmas\u0131 nedeniyle b\u00fck\u00fcl\u00fcr. S\u0131cakl\u0131k, kalibre edilmi\u015f bir s\u0131cakl\u0131\u011fa ula\u015fana kadar y\u00fckselir ve bu noktada bimetalik \u015ferit mandal\u0131 serbest b\u0131rak\u0131r.<\/p>\n<p>Termal devre kesici, kablonun termal kapasitesini taklit eden zaman\/s\u0131cakl\u0131k ters orant\u0131l\u0131 koruma sa\u011flar; b\u00f6ylece termal devre kesici anl\u0131k a\u015f\u0131r\u0131 y\u00fck\u00fc tolere edebilir ancak s\u00fcrekli a\u015f\u0131r\u0131 y\u00fck ko\u015fullar\u0131nda devreyi a\u00e7ar. Termal devre kesiciler manyetik eleman i\u00e7ermedi\u011finden, genellikle k\u0131sa devre ar\u0131za ko\u015fullar\u0131n\u0131 y\u00f6netmek i\u00e7in ek bir cihazla birlikte kullan\u0131l\u0131r.<\/p>\n<h2>Referanslar<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.ul.com\/\" rel=\"nofollow noopener\" target=\"_blank\">UL Solutions \u2013 UL 489 Kal\u0131pl\u0131 Kasa Devre Kesiciler ve UL 1077 Tamamlay\u0131c\u0131 Koruyucular<\/a><\/li>\n<li><a href=\"https:\/\/www.nema.org\/\" rel=\"nofollow noopener\" target=\"_blank\">NEMA \u2013 Kal\u0131pl\u0131 Kasa Devre Kesici Uygulama Verileri<\/a><\/li>\n<li><a href=\"https:\/\/www.hitachienergy.com\/\" rel=\"nofollow noopener\" target=\"_blank\">Hitachi Energy \u2013 D\u00fc\u015f\u00fck Gerilim Koruma ve Anahtarlama Donan\u0131m\u0131<\/a><\/li>\n<li><a href=\"https:\/\/www.schneider-electric.com\/\" rel=\"nofollow noopener\" target=\"_blank\">Schneider Electric \u2013 Devre Kesici Atma E\u011frileri ve Se\u00e7icilik<\/a><\/li>\n<li><a href=\"https:\/\/www.legrand.com\/\" rel=\"nofollow noopener\" target=\"_blank\">Legrand \u2013 Devre Koruma ve Da\u011f\u0131t\u0131m \u00dcr\u00fcnleri<\/a><\/li>\n<\/ul>\n<h2>Sonu\u00e7<\/h2>\n<p>Termal\/manyetik devre kesici, esasen tek bir muhafaza i\u00e7inde iki cihazd\u0131r (termal ve manyetik). Yava\u015f termal eleman kabloyu korurken, h\u0131zl\u0131 manyetik eleman kabloyu ar\u0131zalardan korur. Bu nedenle, bir termal\/manyetik devre kesici se\u00e7erken her \u015fey bu ayr\u0131mdan kaynaklan\u0131r. Bu y\u00fczden, bir elektrik motoru devresi i\u00e7in e\u011fri harfi, ak\u0131m de\u011ferinden daha \u00f6nemlidir.<\/p>\n<p>Terminoloji tuzaklar\u0131n\u0131 anlamak \u00e7ok \u00f6nemlidir. Bir kal\u0131planm\u0131\u015f kutu devre kesici ya termal\/manyetik devre kesici ya da elektronik devre kesici olabilir, bu nedenle birbirleriyle do\u011frudan ili\u015fkili de\u011fillerdir. Sadece manyetik devre kesici, bir ek koruyucu olup, bir dal devre koruma cihaz\u0131 de\u011fildir. Elektronik atma \u00fcniteleri ayarlanabilirlik ve \u00f6l\u00e7\u00fcm yetene\u011fi sa\u011flar, ancak geli\u015fmi\u015f koruma do\u011frulu\u011fu sa\u011flamazlar; bu nedenle, \u00e7o\u011fu da\u011f\u0131t\u0131m panosu her \u00e7\u0131k\u0131\u015f devresi i\u00e7in termal\/manyetik devre kesicilerle donat\u0131lm\u0131\u015ft\u0131r.<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Thermal Magnetic Circuit Breakers (TM CB) are the most popular type of circuit breakers and almost all of the circuitry used in these devices is commercially available to consumers. However, it is common that most consumers do not understand how a TM CB works, therefore it is important to understand their function prior to purchasing [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4695,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_gspb_post_css":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-4694","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs"],"blocksy_meta":[],"_links":{"self":[{"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/posts\/4694","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/comments?post=4694"}],"version-history":[{"count":1,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/posts\/4694\/revisions"}],"predecessor-version":[{"id":4698,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/posts\/4694\/revisions\/4698"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/media\/4695"}],"wp:attachment":[{"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/media?parent=4694"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/categories?post=4694"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/huyuglobal.com\/tr\/wp-json\/wp\/v2\/tags?post=4694"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}