EXBZ7-125 Công tắc chuyển mạch Manual (MTS PC Class)
Up to 125A Changeover with 25mm² Terminals — Load-Break Isolation Included
The EXBZ7-125 extends the EXBZ7 changeover family to 125A, with 25mm² terminals for larger incoming cables and the same 1-0-2 break-before-make operation. It handles mains-to-generator changeover and dual-feeder switching for commercial boards, machine rooms and pump stations, and doubles as a load-break switch disconnector under IEC/EN 60947-3 when the circuit must be isolated for service.
Mô hình
EXBZ7-125 Series — Switch Disconnector / Manual Transfer SwitchEXBZ7-125 (16A / 20A / 25A / 32A / 40A / 63A / 80A / 125A)
IEC/EN 60947-3 · up to 125A · 25mm² terminals · 240/415V · IP20
Chi tiết sản phẩm
- High-current manual changeover switch rated from 16A up to 125A for dual-supply and dual-feeder circuits.
- 25mm² terminals accommodate the larger incoming conductors used in commercial and light industrial boards.
- Rated voltage 240/415V at 50/60Hz; pole options 1P, 2P, 3P and 4P; contact form 1-0-2.
- PC class load-break duty under IEC/EN 60947-3 for mains-generator transfer and maintenance isolation.
Thông tin sản phẩm
Tính Năng Chính & Ứng Dụng Điển Hình
125A Capacity in a DIN Rail Body
The EXBZ7-125 carries the changeover function up to 125A in a rail-mounted switch, covering mains-generator changeover for shops, small plants, telecom shelters and pump houses without moving up to a floor-standing enclosure.
25mm² Terminals for Real Incoming Cables
Terminal capacity grows with the rating: 25mm² accepts the conductors that actually arrive at a 125A changeover point, so terminations are not reduced or doubled up to fit the device.
Two Jobs in One Device
The switch performs the transfer between two sources and, because it is rated as a switch disconnector, it also provides the load-break isolation point for servicing the downstream installation — one device where panels often use two.
Deterministic, Maintenance-Free Operation
No coils, no control voltage, no firmware: the handle position tells you exactly which source is connected and, in the 0 position, that both are isolated. For standby supplies that are used occasionally, that reliability is the whole point.
Thông số kỹ thuật
| Tham số | Chi tiết |
|---|---|
| Dòng | EXBZ7-125 Switch Disconnector / MTS (PC class) |
| Dòng điện còn lại IΔn | 16A / 20A / 25A / 32A / 40A / 63A / 80A / 125A |
| AC 220/230/240V (1P+N, 2P); AC 380/400/415V (3P, 3P+N, 4P) | 240/415V |
| Loại AC | 50/60Hz |
| Số cực | 1, 2, 3, 4P |
| Contact Form | 1-0-2 (break-before-make) |
| Lớp | PC class — load-break switching and switch-disconnector duty |
| Tuổi thọ điện | 1500 cycles |
| Tuổi thọ cơ khí | 8500 cycles |
| Terminal / Cable Size | 25mm² |
| Lắp đặt | DIN rail EN 60715 (35mm) with fast clip device |
| IP20 (thiết bị) / IP40 (trong vỏ) | IP20 |
| Nhiệt độ môi trường | -5°C to +40°C |
| Vật liệu vỏ | Flame-retardant nylon |
| Tiêu chuẩn | IEC/EN 60947-3 |
| Typical Function | Mains-generator changeover · dual feeder switching · load-break isolation |
EXBZ7-125 — When the Changeover Point Has to Handle 125A Without Electronics
Above about 63A the choice of changeover hardware narrows quickly: contactors and automatic transfer switches introduce control circuits and settings, while floor-standing switchgear is expensive for what is often a small room. The EXBZ7-125 fills that space. Rated to 125A with 25mm² terminals in a 35mm DIN rail body, it moves the load between two feeders with a single handle, and the 1-0-2 indexing means mains and generator can never be paralleled — a physical guarantee that no relay logic offers.
Because the device is classified as a switch disconnector under IEC/EN 60947-3, the same handle that transfers the supply also isolates the downstream installation for maintenance. Panels that previously needed a changeover switch plus a separate isolator can be simplified, and the flame-retardant nylon housing with IP20 protection keeps the arrangement compact and finger-safe.
HUYU manufactures the EXBZ7-125 at our own factory and supplies high-current changeover switches and switch disconnectors to panel builders, genset integrators, distributors and OEMs at factory-direct prices, with OEM marking and full IEC/EN 60947-3 documentation.

Nhà sản xuất OEM / ODM trực tiếp từ nhà máy
Chúng tôi sản xuất, bạn thương hiệu
The EXBZ7-125 is built on our own changeover switch lines, where the heavier 125A contact assembly is riveted, the mechanism is indexed through all positions and each batch is sampled for contact resistance and temperature rise under load.
Genset integrators and panel OEMs can order the switch with custom marking and pole configurations matched to their standard changeover assemblies.
- Thương hiệu OEM — housing marking and labels for genset and switchgear brands.
- Tùy chọn ODM — pole counts, rating sets and handle arrangements to suit your assembly.
- Quality documentation — IEC/EN 60947-3 test reports and load-test sampling data.
- MOQ — flexible wholesale quantities; mixed 63A/80A/125A ratings available.

Hướng dẫn mua hàng
For a 125A changeover point, start from the supply current and the incoming cable, then confirm pole count and the upstream protection — the switch handles load-break duty, not short-circuit interruption.
- Read the supply current of the larger of the two sources and select 80A or 125A with margin.
- Match the cable: 25mm² terminals cover typical 125A incoming conductors.
- Choose the poles — 2P for single-phase with neutral, 4P for three-phase with neutral isolation.
- Verify the upstream protective device that clears short-circuit faults.
- Plan source labelling and a lock-off point for maintenance isolation.
- Request samples and confirm marking; production with load-test sampling.
- Wholesale orders shipped globally from the factory.
Cách Chúng Tôi Hỗ Trợ Doanh Nghiệp Của Bạn
OEM / ODM
Custom pole counts, marking and rating sets on the 125A changeover platform, with IEC/EN 60947-3 documentation.
Pole options · Custom marking · Test reports
Bán buôn
Factory-direct pricing on 80A and 125A changeover switches for distributors supplying standby power installations.
Factory pricing · Mixed ratings · Global shipping
Hỗ trợ nhà phân phối
Application notes for mains-generator changeover, cable and pole selection tables and priority production.
Application notes · Priority lead times
Ready to Stock the EXBZ7-125 Series?
OEM/ODM, wholesale pricing and distributor support — one enquiry gets you a factory-direct quotation for 125A changeover switches and switch disconnectors with 25mm² terminals.
Câu hỏi thường gặp
What is a switch disconnector and when is one required?
A switch disconnector is a device that can switch a circuit on and off under load and, in the off position, provides isolation so downstream equipment can be worked on safely. Installations that must be isolated for maintenance — incoming supplies, machine feeds, standby changeover points — generally require a device of this class rather than a plain contactor.
Can the EXBZ7-125 be used for mains-to-generator changeover?
Yes. Connect the mains to one input and the generator to the other, and the handle selects which source feeds the load through the 0 position. Because the changeover is break-before-make, the generator can never be paralleled with the utility — a fundamental safety requirement for standby supplies. It is a manual device, so it suits sites where an operator is present to start the generator and transfer.
Does a 125A changeover switch need a separate isolator?
Usually not. Because the EXBZ7-125 is rated for switch-disconnector duty under IEC/EN 60947-3, it can serve as the isolation point in the off position, provided the upstream protective device handles short-circuit interruption and the installation complies with local rules. Many panels that previously used a changeover switch plus a separate isolator can be simplified to a single device.
How do I choose between the EXBZ7-63 and EXBZ7-125?
Choose by continuous current and cable size. The EXBZ7-63 covers 16-63A with 16mm² terminals; the EXBZ7-125 covers 80A and 125A ratings with 25mm² terminals for larger incoming conductors. Both share the same 1-0-2 operation, PC class rating and 35mm DIN rail mounting.
What protection does the device itself provide?
The switch provides load-break switching and isolation; it does not interrupt short-circuit currents. A fuse or circuit breaker must be installed upstream, sized for the cable and the load. The EXBZ7-125 is rated 240/415V, 50/60Hz, with 1500 electrical and 8500 mechanical operating cycles and IP20 protection.