Protector de Sobretensión y Subtensión EXUR7N/EXUR7

Watch Voltage AND Current — Trip, Display and Reclose Automatically

The EXUR7N and EXUR7 are intelligent over/under voltage protectors for single-phase AC circuits, mounted on a 35mm DIN rail in a standard 2P modular body. They continuously monitor both voltage and current, disconnect the load when overvoltage, undervoltage or overcurrent faults occur, and automatically reclose after the line recovers — protecting refrigerators, air conditioners and electronics from unstable grid supply.

Modelo


EXUR7N / EXUR7 Series — Over & Under Voltage ProtectorEXUR7N-63□ / EXUR7-63□ (40A / 63A / 80A current options)

Solicitar Cotización al por Mayor

AC220V / AC110V · 35mm DIN rail · auto reclose · 19-parameter setup

Voltage + Current Monitoring
Automatic Reclose
19-Parameter Setup

Detalles del Producto

  • Single-phase 2P protector on a 35mm DIN rail with real-time voltage and current display.
  • Overvoltage, undervoltage and overcurrent protection with independent, adjustable thresholds.
  • Automatic reclose after recovery delay; transient-overvoltage immunity against false trips.
  • 40A/63A/80A ratings; AC220V supply (AC110V variant available); 19-parameter menu with setup lock.
Enviar Consulta

Información del Producto

  • Detalles del Producto
  • Descargas
  • Consulta

EXUR7N Overvoltage and Undervoltage Protector

General

EXUR7N Series Intelligent Over/Under Voltage Protector is a DIN-rail mounted intelligent protection device that integrates real-time dual parameter monitoring of voltage and current, multiple protection logic, and automatic fault self-resetting. Featuring a standard 2-pole (2P) modular design, it can be directly mounted on a 35mm DIN rail and is suitable for terminal protection in single-phase AC distribution systems, providing reliable, precise, and intelligent electrical safety protection for connected loads.

Operating Condition

  • Ambient temperature: -25°C~+50°C
  • Relative humidity: <50% at 40°C ( without condensation)
  • Altitude: ≤2000m
  • Environmental conditions: no harmful gases and vapors, no conductive or explosive dust, no severe mechanical vibration.

Característica

Voltage and current display relay used in administrative, industrial and residential buildings and has the function of protecting single-phase lines:

  • Working under voltmeter mode;
  • Undervoltage protection;
  • Overvoltage protection;
  • Overcurrent proteciton.

Datos Técnicos

Supply terminals N,L
Rated supply voltage AC 220V;DC 80-300V
Rated frequency 40/50/60/70Hz
>U setting range AC130-300V;DC130-300V
<U setting range AC80-210V;DC80-210V
Voltage hysteresis 5V
Overvoltage trip delay 0.5s
Voltage accuracy <1%
Max.operating phase voltage 350V
Max.operating current 40A/63A
Altitud <2000m
Ambient temperature -25℃~+50℃
Permissable relative humidity <50%at 40℃(without condensation)
Storage temperature -25℃~+55℃
Tamaño 85*36*66mm
No. Option max min Default Step Unit Descripción
P1 Power-on delay 999 1 5 1/10 S Close overvoltage if greater than 300
P2 Recovery delay 999 1 30 1/10 S Skip this setting when overvoltage is tuned off
P3 Overvoltage 300 130 270 1/10 V Close undervoltage if below 80
P4 Overvoltage recovery value 295 125 265 1/10 V Skip this setting when undervoltage is tuned off
P5 Undervoltage 210 80 170 1/10 V Long press setting is not recommended
P6 Undervoltage recovery value 215 85 175 1/10 V Close overcurrent if greater than 63.0
P7 Overvoltage action delay 10.0 0.1 0.5 0.1/1.0 S 0:Turn off counting
P8 Voltage correction +10% -10% 0 0.5% V Long press setting is not recommended
P9 Overcurrent 63.0 1.0 63.0 0.1/1.0 A Modifying this value will affect the accuracy of the timer
P10 Overflow as delay 10.0 0.1 1.0 0.1/1.0 S 1:Standards
P11 Continuous overcurrent counting 20 0 0 1 Times 2:Manual switch
P12 Current correction +10% -10% 0 0.5% A 3:Automatic switch
P13 Frequency correction +2.5% -2.5% 0 0.1% Hz on:Self-recovery
P14 Rapid power failure protection estas off estas MS off:Manual recovery
P15 Display mode 3 1 1 1 on:Protector working properly
P16 Automatic reset estas off estas off:knife mode
P17 Action/knife mode estas off estas on:Open
P18 Energy saving mode estas off off off:Close
P19 Setup lock password 999 000 112 1/10 When this value is not 112,you can onlyview the
parameter and cannot set it
  • In caseofover-voltagefault, under-valtagefault orover-current tault insingleghaseline, the product canpower line over a time delay after voltageor current of the lineis recovered to normal condition.
  • In case of transient over voltageinline, the product canprotect the equipmant from false aperation.
  • In case that theline subjects to unstable Voltage connectionand other fault, the product willdisconnec theline.
  • When fault vollage of thelinereaches thepeak, the product it self will not bedamaged.

Wiring Diagram / Dimensional Drawing

Wiring Diagram Dimensional Drawing

Front-face Panel

Front-face Panel

Setup Menu

Setup Menu

EXUR7 Overvoltage and Undervoltage Protector

General

EXUR7 Series Intelligent Over/Under Voltage Protector is a DIN-rail mounted intelligent protection device that integrates real-time dual parameter monitoring of voltage and current, multiple protection logic, and automatic fault self-resetting. Featuring a standard 2-pole (2P) modular design, it can be directly mounted on a 35mm DIN rail and is suitable for terminal protection in single-phase AC distribution systems, providing reliable, precise, and intelligent electrical safety protection for connected loads.

Operating Condition

  • Ambient temperature: -25°C~+50°C
  • Relative humidity: <50% at 40°C ( without condensation.
  • Altitude: ≤2000m
  • Environmental conditions: no harmful gases and vapors, no conductive or explosive dust, no severe mechanical vibration

Característica

Voltage and current display relay used in administrative, industrial and residential buildings and has the function of protecting single-phase lines:

  • Working under voltmeter mode;
  • Undervoltage protection;
  • Overvoltage protection;
  • Overcurrent proteciton.

Datos Técnicos

Supply terminals N,L
Rated supply voltage AC 220V;DC 80-300V
Rated frequency 40/50/60/70Hz
>U setting range AC130-300V;DC130-300V
<U setting range AC80-210V;DC80-210V
Voltage hysteresis 5V
Overvoltage trip delay 0.5s
Voltage accuracy <1%
Max.operating phase voltage 350V
Max.operating current 40A/63A
Altitud <2000m
Ambient temperature -25℃~+50℃
Permissable relative humidity <50%at 40℃(without condensation)
Storage temperature -25℃~+55℃
Tamaño 85*36*66mm
No. Option max min Default Step Unit Descripción
P1 Power-on delay 999 1 5 1/10 S Close overvoltage if greater than 300
P2 Recovery delay 999 1 30 1/10 S Skip this setting when overvoltage is tuned off
P3 Overvoltage 300 130 270 1/10 V Close undervoltage if below 80
P4 Overvoltage recovery value 295 125 265 1/10 V Skip this setting when undervoltage is tuned off
P5 Undervoltage 210 80 170 1/10 V Long press setting is not recommended
P6 Undervoltage recovery value 215 85 175 1/10 V Close overcurrent if greater than 63.0
P7 Overvoltage action delay 10.0 0.1 0.5 0.1/1.0 S 0:Turn off counting
P8 Voltage correction +10% -10% 0 0.5% V Long press setting is not recommended
P9 Overcurrent 63.0 1.0 63.0 0.1/1.0 A Modifying this value will affect the accuracy of the timer
P10 Overflow as delay 10.0 0.1 1.0 0.1/1.0 S 1:Standards
P11 Continuous overcurrent counting 20 0 0 1 Times 2:Manual switch
P12 Current correction +10% -10% 0 0.5% A 3:Automatic switch
P13 Frequency correction +2.5% -2.5% 0 0.1% Hz on:Self-recovery
P14 Rapid power failure protection estas off estas MS off:Manual recovery
P15 Display mode 3 1 1 1 on:Protector working properly
P16 Automatic reset estas off estas off:knife mode
P17 Action/knife mode estas off estas on:Open
P18 Energy saving mode estas off off off:Close
P19 Setup lock password 999 000 112 1/10 When this value is not 112,you can onlyview the
parameter and cannot set it
  • In caseofover-voltagefault, under-valtagefault orover-current tault insingleghaseline, the product canpower line over a time delay after voltageor current of the lineis recovered to normal condition.
  • In case of transient over voltageinline, the product canprotect the equipmant from false aperation.
  • In case that theline subjects to unstable Voltage connectionand other fault, the product willdisconnec theline.
  • When fault vollage of thelinereaches thepeak, the product it self will not bedamaged.

Wiring Diagram / Dimensional Drawing

EXUR7 Wiring Diagram Dimensional Drawing

Front-face Panel

EXUR7 Front-face Panel

Setup Menu

EXUR7 Setup Menu

Cómo apoyamos su negocio

EXUR7N OEM voltage protector customization

Custom faceplates, market-specific factory defaults and packaging on the standard DIN rail platform.


Custom faceplates · Factory defaults · Calibration data

EXUR7N voltage protectors wholesale supply

Venta al por mayor

Más información →

Factory-direct pricing for distributors in high-voltage-fluctuation markets where appliance protection is a fast-growing category.


Precio de fábrica · MOQ flexible · Envío global

EXUR7N distributor technical support for voltage protectors

Soporte para distribuidores

Más información →

Market-setup guides, threshold tables and priority production for channel partners in residential electrical retail.


Setup guides · Threshold tables · Priority lead times

Ready to Stock the EXUR7N / EXUR7 Series?

OEM/ODM, wholesale pricing and distributor support — one enquiry gets you a factory-direct quotation for over/under voltage protectors in 40A, 63A and 80A ratings, pre-set to your market’s voltage window.

Contacte a nuestro equipo de ventas

Preguntas Frecuentes

What is an over/under voltage protector and why install one?

An over/under voltage protector disconnects a load when the line voltage leaves a safe window — for example above 270V or below 170V on a 220V line — and reconnects it after the supply recovers. It protects compressors, refrigerators, air conditioners and electronics from brown-outs, neutral drift and grid surges. The EXUR7N/EXUR7 also monitors current, adding overcurrent protection for the circuit.

What is the difference between EXUR7N and EXUR7?

Functionally they are identical — the same dual voltage/current monitoring, the same protection logics and the same 19-parameter setup. EXUR7N and EXUR7 are two model-name families within the same platform, offered so different distribution channels and markets can carry separate part numbers. Order either; specify the current rating (40/63/80A) and supply voltage.

Does the protector reset automatically after a fault?

Yes, if auto-reclose is enabled. After an overvoltage, undervoltage or overcurrent trip, the protector waits for the configured recovery delay (default 30 tenths of a second units in the P2 parameter) and reconnects automatically once conditions are normal. Set the menu to manual recovery where an attended reset is required by local rules.

Where should it be installed — before or after the main breaker?

The protector protects a branch or the whole single-phase load, so it is installed downstream of the main overcurrent device, on the DIN rail of the distribution board, upstream of the socket circuits or appliances it guards. Its own terminals are rated for the model’s current (40/63/80A); the upstream breaker provides short-circuit backup.

Can it be used on a 110V supply?

Yes — the EXUR7N/EXUR7 platform includes an AC110V supply variant in addition to the standard AC220V version, with the same over/under voltage and overcurrent functions scaled to the 110V window. Confirm the supply variant when ordering.