HYET3 Dual Power Auto Changeover Switch – 20A to 1600A,2P/3P/4P
The HYET3 is a PC-class dual power auto changeover switch rated 20A–1600A for AC 230V/400V systems. Available in two-position and three-position (center-off) configurations. 2P, 3P, and 4P for single-phase and 3-phase. Adjustable switching time 0–255S. Mechanical life up to 6000 ops. For generator backup and dual-grid systems.
Standard: GB/T 14048.11
Rated Current: 20A – 1600A
Configurations: Two-position / Three-position
Poles: 2P, 3P, 4P
Rated Voltage: AC 230V (2P) / AC 400V (3P, 4P)
Switching Time: 0–255S adjustable
Product Grade: PC class
Product Information
HYET3 Dual Power Automatic Transfer Switch — PC Class, 20A–1600A
The HYET3 Dual Power Automatic Transfer Switch is manufactured by HUYU Electric, leveraging over 30 years of expertise. Designed for AC 50Hz circuits up to 400V, the PC-class ATS is available in seven frame sizes, covering 20A to 1600A. The product offers flexibility with two configuration options: a two-position (I–II) and a three-position (I–0–II) version. The three-position version features a center-off position for dual-break isolation, enhancing safety during maintenance without affecting transfer reliability.
The integrated controller supports an adjustable switching time of 0–255 seconds, allowing customization for generator start-up or grid reconnection delays. With a robust 100kA/120kA limited short-circuit current (Iq) and AC-33i use categories for certain frames, the HYET3 is equipped to handle demanding industrial environments. HUYU Electric provides factory-direct OEM/ODM services with private labeling and complete documentation for auto changeover switches used in backup power and dual-grid applications.

Model Range – Seven Frame Sizes, 20A to 1600A
| Model | Rated Current | Use Category | Iq (kA) | Mechanical Life | Operation Cycle |
|---|---|---|---|---|---|
| HYET3-63 | 20A – 63A | AC-33B (AC-33A opt.) | 100 | 6,000 | 30S |
| HYET3-125 | 63A – 125A | AC-33B (AC-33A opt.) | 100 | 6,000 | 30S |
| HYET3-250 | 125A – 250A | AC-33B (AC-33iA opt.) | 100 | 6,000 | 30S |
| HYET3-630 | 315A – 630A | AC-33B (AC-33iA opt.) | 100 | 6,000 | 30S |
| HYET3-800 | 630A – 800A | AC-33B (AC-33iA opt.) | 120 | 5,000 | 60S |
| HYET3-1250 | 800A – 1250A | AC-33iB | 120 | 5,000 | 60S |
| HYET3-1600 | 1250A – 1600A | AC-33iB | 120 | 5,000 | 60S |
All HYET3 models are dual power transfer switches built on a unified PC-class platform. Frames up to 630A carry a 100kA Iq rating, while 800A–1600A frames are rated at 120kA. The operation cycle is 30 seconds for smaller frames, extending to 60 seconds for 800A and above for better thermal load management.
Configuration Flexibility & Adjustable Timing
The HYET3 offers two mechanical configurations: two-position (I–II) for standard source-to-source transfers and three-position (I–0–II) with center-off for isolation. Both configurations share the same voltage, current, and pole options, providing full flexibility without altering product families. The switching time is adjustable between 0 and 255 seconds, accommodating diverse generator start sequences and grid reconnection requirements. This makes the HYET3 an ideal choice as an automatic changeover switch for generator applications, where precision timing is often critical.
Technical Specifications
| Product Model | HYET3 Series Dual Power ATS |
| Standard | GB/T 14048.11 |
| Rated Current | 20A – 1600A |
| Rated Working Voltage Ue | 2P: AC 230V | 3P/4P: AC 400V |
| Rated Insulation Voltage Ui | AC 800V |
| Impulse Withstand Uimp | 8kV |
| Limited Short-circuit Current Iq | 100kA (63–630); 120kA (800–1600) |
| Poles / Configurations | 2P, 3P, 4P; Two-position / Three-position |
| Switching Time | 0–255S adjustable |
| Mechanical / Electrical Life | 6,000/1,500 (63–630); 5,000/1,000 (800–1600) |
| MOQ | Contact for project quotation |

Request a Quotation for HYET3 Dual Power Transfer Switches
20A–1600A, PC class. Two-position or center-off three-position. 2P/3P/4P. 0–255S adjustable switching. OEM/ODM with full documentation. Contact us for pricing and lead time.
Project-Based Quotation • GB/T 14048.11 • Worldwide Shipping
OEM/ODM Supply – Engineered Since 1993
HYET3 – 30+ Years of Power Distribution Engineering
The HYET3 is designed by experienced power engineers with decades of expertise. As a PC class ATS, it provides an alternative to global brands like Socomec, ABB, and ASCO. Key features include a 100kA–120kA Iq rating, two-position or center-off mechanisms, and 0–255S adjustable timing. Comprehensive private labeling, testing, and project-based support are offered for OEM/ODM buyers. HUYU Electric’s manufacturing experience since 1993 stands behind every unit.
How to Select a Dual Power Auto Changeover Switch
Key selection criteria for the HYET3 in generator backup and dual-grid systems.
1. Two-Position or Three-Position?
Choose the two-position (I–II) configuration for standard generator automatic transfer switch applications. Select the three-position (I–0–II) version for maintenance procedures or local codes that require visible load isolation. The center-off position is also useful for generator testing without connecting to the building load.
2. Setting the Switching Time
The 0–255S adjustment covers various scenarios. Diesel generators typically need 10–30 seconds to stabilize before accepting load. For dual-grid transfers, a shorter 1–5 second setting minimizes disturbance. This flexibility eliminates the need for external timing relays in most installations.
3. Use Category & Frame Selection
Frames up to 800A default to AC-33B, with AC-33iA available for frequent switching. The 1250A–1600A frames use AC-33iB. Match the use category to the expected operation frequency. For 3-phase systems, choose 3P or 4P based on neutral switching requirements.
4. Short-Circuit Verification
Ensure the HYET3’s Iq rating (100kA or 120kA) exceeds the prospective fault current at the installation point. The PC class rating ensures safe performance in high-fault industrial environments.




Frequently Asked Questions
How does the automatic changeover switch work?
An automatic changeover switch monitors the primary power source and, upon detecting a fault such as undervoltage or phase loss, automatically transfers the load to a standby source — typically a generator. The HYET3 executes this transfer within a user-adjustable time of 0–255 seconds. Once the primary source is restored and stable, the switch returns the load, ensuring seamless power continuity.
What are the common problems with ATS panels?
Frequent issues with ATS panels include contact welding under short circuits and nuisance transfers from incorrect voltage thresholds. The HYET3’s PC class rating certifies short-circuit withstand without welding. Its adjustable switching time and undervoltage settings help eliminate nuisance operations. Regular operational testing and torque checks further prevent field failures.
Is there an automatic transfer switch?
Yes. The HYET3 is a complete automatic transfer switch platform covering 20A to 1600A. It is available in two-position and three-position configurations, with 2P, 3P, and 4P versions for single-phase and 3-phase systems. All units are PC class and include an integrated controller with adjustable timing.
Is it legal to install your own transfer switch?
Installation of an automatic transfer switch must be performed by a licensed electrician in virtually all jurisdictions. This ensures compliance with local wiring codes, proper grounding, and correct integration with the grid. While the HYET3 is designed for straightforward fixed installation, professional installation is required for safety and regulatory compliance.
No documents available for download at this moment.