HUW9NE High Voltage Air Circuit Breaker – 630A to 6300A
The HUW9NE is a high voltage air circuit breaker (ACB) rated 630A–6300A for AC 400V–1140V systems. Zero arc performance with Icu up to 125kA and Icw up to 100kA/1s. Intelligent modular controller. Draw-out and fixed mounting. Total breaking time ≤25ms. For new energy, industrial, and power distribution applications.
Standard: IEC 60947-2
Rated Current: 630A – 6300A
Rated Voltage: AC 400V – 1140V
Breaking Capacity: Up to 125kA Icu
Poles: 3P
Breaking Time: ≤25ms
Mounting: Fixed / Draw-out
Product Information
HUW9NE High Voltage Air Circuit Breaker – Zero Arc, 630A to 6300A
The HUW9NE series Air Circuit Breaker (ACB) offered by HUYU Electric provides superior protection for high voltage AC installations at 1140V or below. Ranging from 630 amps (A) to 6300 A, the ACBs protect everything from an 800 A ACB used in a commercial building to a 3200 A or 4000 A ACB used in utility-scale new energy generation projects. Advanced arc extinction technology allows the ACBs to provide zero-arc performance, making them a safe choice for compact switchgear used in photovoltaic installations, wind farms, and battery storage systems.
The modular intelligent controller and operating mechanism are separate components facilitating simplified maintenance and replacement. Total breaking time is ≤ 25 ms with short-time withstand currents ≤ 100 kA/1 sec (for selected frames), therefore providing complete selectivity for downstream circuit breakers. Manufacturers looking for ACB OEM supply will find that HUYU Electric provides factory-direct prices for each ACB from 630A to 6300A, along with complete IEC 60947-2 documentation and private label options.

Breaking Performance & Frame Currents
| Model | Frame Current | Rated Current Range | Rated Voltage | Icu at 400V | Icw/1s | Mechanical Life |
|---|---|---|---|---|---|---|
| HUW9NE-2500 | 2500A | 630A–2000A | 400V/690V/800V | 80kA | 80kA | Maintenance-free |
| HUW9NE-3200 | 3200A | 630A–3200A | 400V/690V/800V/1000V/1140V | 100kA | 100kA | 12,500 |
| HUW9NE-4000 | 4000A | 630A–4000A | 400V/690V/800V/1000V/1140V | 100kA | 100kA | 10,000 |
| HUW9NE-6300 | 6300A | 4000A–6300A | 400V/690V/800V/1000V/1140V | 125kA | 100kA | 6,500 |
Zero Arc Technology & Modular Intelligence
The HUW9NE’s arc suppression system provides zero arc performance, containing and extinguishing the arc entirely within the chamber with no external arc flash reaching the switchgear compartment. This ensures safety for air circuit breakers installed in containerized substations or compact power houses. The intelligent controller module has adjustable protection settings (LSIG) and can be replaced without removing the entire breaker. This modular approach applies across all ratings, from a 1600 amp ACB to the largest 6300A unit.
Technical Specifications
| Product Model | HUW9NE Series Air Circuit Breaker (ACB) |
| Standard | IEC 60947-2 |
| Frame Sizes | 2500, 3200, 4000, 6300 |
| Rated Current In | 630 – 6300A (800A, 1000A, 1250A, 1600A, 2000A, 2500A, 3200A, 4000A, 5000A, 6300A) |
| Rated Voltage Ue | AC 400V / 690V / 800V / 1000V / 1140V |
| Frequency | 50/60Hz |
| Poles | 3P |
| Icu at 400V | 80kA – 125kA |
| Icw/1s at 400V | 80kA – 100kA |
| Total Breaking Time | ≤25ms |
| Utilization Category | B |
| Arcing Distance | 0 (zero arc) |
| Mounting | Fixed / Draw-out |
| MOQ | Contact for project quotation |

Request a Quotation for HUW9NE Air Circuit Breakers – All Current Ratings
630A–6300A, AC 400V–1140V. Available in 800A, 1000A, 1250A, 1600A, 2000A, 2500A, 3200A, 4000A, 5000A, 6300A. Icu up to 125kA. Zero arc. Draw-out or fixed. IEC 60947-2. OEM/ODM with full documentation. Contact us for pricing and lead time.
Project-Based Quotation • IEC 60947-2 • Worldwide Shipping
OEM/ODM Supply – High Voltage ACB for New Energy and Industry
HUW9NE – One Platform, All Ratings from 800A to 6300A
The HUW9NE is engineered for applications where standard 400V breakers fall short. As a high voltage air circuit breaker reaching 1140V, it serves photovoltaic plants, wind farms, and energy storage systems that demand an 800 amp ACB, 1600 amp ACB, 2000 amp ACB, or larger. The modular controller, zero arc technology, and draw-out option make it a direct alternative to established global brands. For OEM buyers, HUYU Electric provides private labeling, full IEC test reports, and dedicated project management from specification to delivery — backed by manufacturing experience that spans the complete air circuit breaker range up to 6300A.
How to Select the Right Air Circuit Breaker Current Rating
Choosing the correct amp rating for the HUW9NE ACB in new energy and industrial projects.
1. Matching Current Rating to Load
For commercial building incomers under 1000A, select an 800 amp air circuit breaker or 1000 amp ACB. For larger facilities and solar PV sub-stations, a 1600 amp or 2000 amp ACB is common. Utility-scale renewable interconnections often require 2500 amp, 3200 amp, or 4000 amp ACB ratings. The HUW9NE covers all these levels with adjustable settings within each frame, so you are not locked into a single fixed current.
2. Voltage Rating for New Energy
If your system operates at 690V or 800V, the entire HUW9NE range applies. For 1000V or 1140V systems — increasingly common in large PV and battery storage — select the HUW9NE-3200, -4000, or -6300 frames. These higher voltage air circuit breakers eliminate the need for an extra transformation stage, reducing losses and equipment cost.
3. Short-Circuit Coordination
The HUW9NE’s Icw of up to 100kA allows downstream ACB breakers and MCCBs to clear faults without tripping the main incomer. When specifying an air circuit breaker for selective coordination, verify that the short-time withstand current exceeds the maximum prospective fault current at the installation point. The 4000A and 6300A frames are particularly suited for this duty.
4. Fixed vs. Draw-out
Draw-out construction is recommended for critical incomers — including 2000 amp ACB and larger — where rapid replacement during planned maintenance or fault recovery minimizes downtime. Fixed mounting is suitable for dedicated circuits where the breaker will remain in service long-term.




Frequently Asked Questions
What is a high-voltage circuit breaker?
A high-voltage circuit breaker is a protection device designed to interrupt fault currents in electrical systems operating above standard low-voltage levels. While IEC standards define high voltage as exceeding 1000V AC, in the context of low-voltage power distribution, breakers rated for 800V, 1000V, and 1140V systems are classified as high voltage air circuit breakers due to their enhanced insulation and breaking capabilities. The HUW9NE is built for these elevated voltages, covering current ratings from 630A to 6300A — including 800 amp, 1600 amp, 2000 amp, 3200 amp, and 4000 amp air circuit breaker configurations — making it suitable for utility-scale photovoltaic, wind, and industrial applications where standard 400V breakers are not rated for the system voltage.
What is the purpose of an air circuit breaker?
The primary purpose of an air circuit breaker is to provide overcurrent and short-circuit protection for main incomers and large feeder circuits in low-voltage switchgear. An ACB serves as the first line of defense: it must carry high continuous currents (630A and above), detect fault conditions, and interrupt the circuit safely using air as the arc extinguishing medium. In new energy applications, an air circuit breaker rated for 1000V or 1140V — such as the HUW9NE in 2500 amp, 3200 amp, 4000 amp, or 6300 amp frame sizes — protects the AC incomer of photovoltaic and wind installations, coordinates selectively with downstream breakers, and provides a visible isolation point when draw-out construction is specified.
What is the difference between a circuit breaker and an air circuit breaker?
An ACB air circuit breaker differs from a standard molded case circuit breaker (MCCB) in scale, capability, and application. MCCBs typically cover up to 1600A at 400V–690V. An air circuit breaker like the HUW9NE extends to 6300A and supports voltages up to 1140V. Key technical differences: ACBs use atmospheric air as the arc extinguishing medium with sophisticated arc chutes, achieving zero arc performance; they provide higher short-time withstand current (Icw up to 100kA) for full selective coordination with downstream devices; and they offer draw-out construction for rapid replacement. The HUW9NE is available in current ratings from 630A to 6300A — covering 800 amp ACB, 1600 amp ACB, 2000 amp ACB, and 3200 amp ACB configurations — placing it firmly in the ACB category.
What are the disadvantages of Air circuit breakers?
Traditional air circuit breakers have a larger physical footprint than MCCBs, which can be a constraint in compact switchgear. Their arc extinguishing process generates ionized gases that require ventilation within the enclosure. Maintenance intervals can be more frequent on older designs. The HUW9NE addresses several of these traditional drawbacks: its compact modular design reduces footprint relative to current rating; the zero arc technology confines arc products entirely within the chamber, requiring no external venting; and the independent modular controller and mechanism allow component-level replacement without full breaker overhaul. For buyers specifying air circuit breakers rated 630A and above — including 800 amp, 1000 amp, 1250 amp, 1600 amp, 2000 amp, 2500 amp, and 3200 amp air circuit breaker ratings — the key selection consideration remains balancing the higher initial cost of an ACB against its superior breaking capacity and maintainability compared to multiple paralleled MCCBs.