Home > Product > All Product > EXU7 Surge Protection Device (SPD)

EXU7 Surge Protection Device (SPD)

Type 2 Surge Protection with Pluggable Modules and Remote Status

The EXU7 is a Type 2 surge protective device for 230/400V distribution boards, clamping lightning and switching transients before they reach connected equipment. Pluggable modules speed replacement after a strike, the green/red status window shows condition at a glance, and an optional remote signalling contact reports a failed cartridge back to a BMS or alarm panel.

Model

✓
EXU7 Series — Type 2 Surge Protection DeviceEXU7-II · 1P/2P/3P/4P · 1P+N / 3P+N · Uc 275/320/385V · In 10-20kA · Imax 20-40kA

Request a Wholesale Quotation

IEC 61643-11 · Class II (T2), 8/20µs · Up 1.2-1.8kV · response under 25ns · IP20

Imax up to 40kA
Under 25ns Response
Pluggable Modules

 

Send Inquiry

Product Information

  • Product Details
  • Downloads
  • Inquiry

Product Overview

Main Functions: The EXU7 Series Surge Protective Devices (SPDs) are primarily designed for single-phase and three-phase AC power distribution systems operating at 50Hz/60Hz, with rated voltages of 230V/400V.They are used to suppress transient overvoltages, discharge surge energy, and prevent or minimize damage to electrical equipment caused by transient overvoltages resulting from lightning strikes or switching operations.

Compliance with Standards :IEC 61643-11

Product Features

– High-quality chips ensure stable and reliable performance.
– Visual status indicator for easy monitoring of device status.
– Modular design for easier installation and maintenance.
– Optional remote signaling alarm accessory enables remote monitoring of SPD status.

Main Specifications

Parameter Specification
Rated Operating Voltage(Un) 230VAC(Phase Voltage)
Number of Poles 1P/2P/3P/4P/1P+N/3P+N
Test Classification T2(Type 2)
Maximum Continuous Operating Voltage(Uc) 275/320/385V
Nominal Discharge Current(In) 10-20kA
Maximum Discharge Current(Imax) 20-40kA
Voltage Protection Level(Up) 1.2-1.8kV

Technical Specifications

Compliant Standards IEC61643-11
Rated Voltage(Uh) 230 VAC(phase voltage)
Number of Poles 1P,2P,3P,4P,1P+N,3P+N
Model EXU7-II
Test Class Class II(T2)
Waveform(μs) 8/20 μs
Nominal Discharge Current(In) 10kA 20kA
Maximum Discharge Current(Imax) 20kA 40kA
Maximum Continuous Operating Voltage(Ue) 275V/320V/385V
Voltage Protection Level(Up)(kV) 1.2/1.4/1.5 1.5/1.7/1.8
Operating Status Indicator Window Green:Normal;Red:Failed
Recommended Backup Circuit Breaker 20A 40A
Recommended Backup Fuse(gL/gG) 50A                                    100A
Response Time <25ns
Remote Signaling Function Configuration:12(Normally Open),13(Normally Closed)
In the event of a fault,terminal 12(Normally Open)closes,
and terminal 13(Normally Closed)opens.
Wiring Capacity Solid wire ≤35mm²,stranded wire 2.5-25mm²;maximum tightening torque 3.5N ·m
Degree of Protection(IP Rating) IP20

Overall and Mounting Dimensions

Dimensional Drawing

EXU7 SPD Dimensional Drawing

Standard Wiring

EXU7 SPD Standard Wiring

Wiring Diagram for Remote Signaling Function

Compliant with standard: IEC 61643-11

Main Specifications
Remote Signaling(YX)
Parameter Specification
AC Operating Voltage/Current 250V AC,0.5Amax
DC Operating Voltage/Current 250V DC,0.1A max
125V DC,0.2Amax
24V DC,1A max
Contacts One Normally Open(NO)Contact and
One Normally Closed(NC)Contact
Function When the SPD module fails or becomes disconnected,
the normally open(NO)contact closes and the normally
closed(NC)contact opens.
Terminal Connection Capacity 1.5  mm²(max)